Results of multifield conformal radiation therapy of nonsmall-cell lung carcinoma using multileaf collimation beams.

A five-field conformal technique with three-dimensional radiation therapy treatment planning (3-DRTP) has been shown to permit better definition of the target volume for lung cancer, while minimizing the normal tissue volume receiving greater than 50% of the target dose. In an initial study to confirm the safety of conventional doses, we used the five-field conformal 3-DRTP technique. We then used the technique in a second study, enhancing the therapeutic index in a series of 42 patients, as well as to evaluate feasibility, survival outcome, and treatment toxicity. Forty-two consecutive patients with nonsmall-cell lung carcinoma (NSCLC) were evaluated during the years 1993-1997. The median age was 60 years (range 34-80). The median radiation therapy (RT) dose to the gross tumor volume was 6,300 cGy (range 5,000-6,840 cGy) delivered over 6 to 6.5 weeks in 180-275 cGy daily fractions, 5 days per week. There were three patients who received a split course treatment of 5,500 cGy in 20 fractions, delivering 275 cGy daily with a 2-week break built into the treatment course after 10 fractions. The stages of disease were II in 2%, IIIA in 40%, IIIB in 42.9%, and recurrent disease in 14.3% of the patients. The mean tumor volume was 324.14 cc (range 88.3-773.7 cc); 57.1% of the patients received combined chemoradiotherapy, while the others were treated with radiation therapy alone. Of the 42 patients, 7 were excluded from the final analysis because of diagnosis of distant metastasis during treatment. Two of the patients had their histology reinterpreted as being other than NSCLC, 2 patients did not complete RT at the time of analysis, and 1 patient voluntarily discontinued treatment because of progressive deterioration. Median follow-up was 11.2 months (range 3-32.5 months). Survival for patients with Stage III disease was 70.2% at 1 year and 51.5% at 2 years, with median survival not yet reached. Local control for the entire series was 23.3+/-11.4% at 2 years. However, for Stage III patients, local control was 50% at 1 year and 30% at 2 years. Patients who received concurrent chemotherapy had significantly improved survival (P = 0.002) and local control (P = 0.004), compared with RT alone. Late esophageal toxicity of > or =Grade 3 occurred in 14.1+/-9.3% of patients (3 of 20) receiving combined chemoradiotherapy, but in none of the 15 patients treated with RT alone. Pulmonary toxicity limited to Grades 1-2 occurred in 6.8% of the patients, and none developed > or =Grade 3 pulmonary toxicity. Patients with locally advanced NSCLC, who commonly have tumor volumes in excess of 200 cc, presenta challenge for adequate dose delivery without significant toxicity. Our five-field conformal 3-DRTP technique, which incorporates treatment planning by dose/volume histogram (DVH) was associated with minimal toxicity and may facilitate dose escalation to the gross tumor.

Adenocarcinoma

Dosimetric consequences of 10B(n, alpha)7Li reaction occurring at the cellular membrane.

PURPOSE: Microdosimetric expectations of Boron contents are extracted from a CRAY-Monte Carlo simulation of the nuclear reaction 10B(n, alpha)7Li as it occurs on a boronated membrane of a model cell and as the reaction fragments (alpha and Li) traverse into the cellular nucleus. METHODS AND MATERIALS: The present microdosimetry calculation is based upon the assumption that the therapeutic advantage of boron neutron capture therapy (BNCT), while depending upon the RBE and LET of the reaction particles, is equally dependent on the boron carrier preferential localization to tumor tissue, and the boron selectivity to cancerous cells and its specificity within subcellular compartments. In particular, boron fixes to cell membrane as it ought to, using monoclonal antibodies. The present Monte Carlo simulation computes stochastic expectations of alpha/Li energy depositions to the nucleus in a uniformly boronated membrane shell of a spherical cell. Differential energy gain was deduced from the stochastic energy depositions in events of neutron reactions with membrane boron compared against those with natural elements (O, H, N) in the cell. RESULTS: Microdosimetry data are presented in terms of specific energy (keV/micron3) and lineal energy (keV/micron) functions of the nucleus-to-cell volume ratios (NCVR). When folded with the geometric boron content and accounting for background reaction energies, the distributions yield effective energy gain to the cell nucleus per neutron capture event. Boron amount required to yield these energy gains are found to be of the order of picograms of boron per gram of cell mass. CONCLUSION: The boron content as inferred by the present Monte Carlo microdosimetry compares well with that deliverable by present pharmacokinetic means, but are orders of magnitude (mu-grams) less than those deduced previously from anthropomorphic macrodosimetry.

Alpha Particles

Transmission block technique for the treatment of the pelvis and perineum including the inguinal lymph nodes: dosimetric considerations.

Radical radiotherapy of pelvic malignancies (e.g., vulva, anus) includes therapeutic dosage to the inguinal nodes. To minimize the dosage to the femoral head, the transmission block technique has been developed to fully irradiate the central pelvis midplane and inguinal nodes. Originally, this technique compensated for dose inhomogeneity in the transverse plane only. In some patients, however, we have observed a significant dose variation along the sagittal plane. The authors have developed a lead compensation technique to homogenize the sagittal dose variations due to the longitudinal sloping in the patient, along with further refinements in this technique. Dosimetric and technical details are also discussed.

Anus Neoplasms

Clinical use of a wing field with transmission block for the treatment of the pelvis including the inguinal node.

Treatment planning of photon and electron beams to include the pelvis and the groin poses a technical difficulty of positioning beams, and a dosimetric problem of abutting fields at the groin. We have analyzed a simpler AP/PA method using a central transmission block. The posterior portal is smaller and opposes only the pelvic portion of the anterior portal under the transmission block, while the anterior extended portion (hence the wing) is unattenuated to treat the inguinal region. By calculating the attenuation thickness according to the patient's separation and the beam quality, the dose distribution is tailored to yield the proper dose to the pelvic mid-plane and the inguinal nodes while minimizing the dose to the femora. Measured dose distribution (6MV) using film dosimetry in a tissue-equivalent phantom indicates that a 30% hot spot is created by the posterior portal diverging into the wings of the anterior field. Therefore, the pelvic attenuator is tapered at its lateral edges, thereby significantly reduced the dose inhomogeneity (5%) at the groin. Clinical methods are outlined for the verification of the patient portal films against possible mismatch in beam divergence.

Groin

Treatment planning for gamma knife radiosurgery with multiple isocenters.

Many arteriovenous malformations and tumors suitable for radiosurgical treatment have non-spherical or irregular shapes. Forty-eight percent of the first 156 patients treated with the gamma unit at the University of Pittsburgh required treatment with two or more isocenters to optimize dose distributions. Dose distributions for combining gamma knife treatments to two or more isocenters were systematically investigated. High speed computerized dosimetry was performed using specially developed software and dose distributions were confirmed with film densitometry. We have developed guidelines for treatment to two or more isocenters which help reduce treatment planning time, and facilitate selection of treatment doses and optimum dose distributions. These guidelines include maintaining an account of the distances between all isocenters, using a catalogue of sample two-isocenter isodose plans, comparing dose volume histograms, and calculating complication probabilities using the integrated logistic formula.

Cobalt Radioisotopes

Physics of gamma knife approach on convergent beams in stereotactic radiosurgery.

The Presbyterian-University Hospital of Pittsburgh installed the first clinically designated Leksell gamma knife in the U.S. in August 1987. Gamma knife radiosurgery involves stereotactic target localization with the Leksell frame and subsequent closed-skull single-treatment session irradiation of a lesion with multiple highly focused gamma ray beams produced from 60Co sources. The hemispherical array of sources, the large number of small-diameter beams, and the steep dose gradients surrounding a targeted lesion make physical characterization of the radiation field complex. This paper describes the physical features and the operation of the gamma knife as well as the calibration procedures of the very small, well-collimated beams. The results of studies using in-phantom ion chamber, diode, film, and lithium fluoride thermoluminescent dosimetry were all in close agreement. Both single-beam and multiple-beam dose profiles were measured and reported for the interchangeable helmets, which have 4-, 8-, 14-, and 18-mm-diameter collimators. We also describe the dose calculation and treatment planning algorithm in the treatment planning system. Measurements of the accuracy of mechanical and radiation alignment are also performed and discussed.

Brain Diseases

Polyacrylamide-based phantoms as tissue substitute in experimental radiation physics.

Polyacrylamide-based tissue-equivalent phantoms simulating cortical bone and muscle are described. The equivalency is based upon similar elemental composition and density, and partial similarity in the morphology of bone. Satisfactory results were obtained when the phantoms were tested at low (20 keV) and high (15 MeV) gamma radiation. Applicability of this phantom material to neutron transport is discussed. The material can be molded and shaped and its composition is easily modified by altering the proportions of the constituents. Trace elements or radionuclides are easily added. Details of the physical and radiation characteristics of the formulated systems are given together with the manufacturing procedures.

Acrylic Resins

A beam-edge modifier for abutting electron fields.

Abutment of unmodified electron fields to irradiate large areas can lead to significant dose inhomogeneities in the region of junction of the fields. In this paper we describe the design and dosimetric characteristics of a device developed to broaden the electron beam penumbra and thereby to improve the dose uniformity in the overlap region. The device is a high-density triangular-toothed comb capable of reducing the beam intensity without seriously degrading the beam energy. The effect of the comb is such that a single device will generate a beam penumbra which is broad and very nearly linear at all depths for all clinically used beam energies. Results are shown for various field configurations and energies. With a gap of 5.0 cm between the treatment cone and phantom surface the dose "ripple" in the region beneath the teeth was found not to exceed +/- 5% at 0.5-cm depth.

Electrons

Separation of dose-gradient effect from beam-hardening effect on wedge factors in photon fields.

It is known experimentally that a wedge transmission factor depends upon the field size and depth of measurement in particular. Dependence of the transmission upon depth has been attributed to a hardening of the incident beam through the filter, which preferentially absorbs the low-energy photon of the bremsstrahlung component of that beam. We have attempted to separate this hardening effect from that of increased phantom scatter due to dose gradient induced by the wedge filter. Using an experimental wedge machined from cerrobend, the filter transmission at depth is measured and redefined relative to an "equally hardened" beam, obtained by filtering through a flat slab of equal thickness at the center of the wedge. Results of the Co-60, 4-, and 8-MV wedged beams indicate that nearly half of the increase in the transmission at depth is due to the effect of dose-gradient scatter in polystyrene phantom. Based on a simple relationship between primary and scattering radiation, an algebraic presentation is indeed in support of the dose gradient resulting in apparent increase in the wedge factors, at depth.

Cobalt Radioisotopes