[Automated procedures for microscopic analyses of blood smears: medical testing a MECOS-Ts2 complex].

The paper presents the results of medical tests of a group of computer-aided procedures for microscopic analysis by means of a MECOS-Ts2 complex (ZAO "MECOS", Russia), which have been conducted at the Republican Children's Clinical Hospital, the Research Institute of Emergency Pediatric Surgery and Traumatology, and Moscow City Clinical Hospital No. 23. Computer-aided procedures for calculating the differential count and for analyzing the morphology of red blood cells were tested on blood smears from a total of 443 patients and donors, computer-aided calculation of the count of reticulocytes was tested on 318 smears. The tests were carried out under the US standard NCCLS-H20A. Manual microscopy (443 smears) and flow blood analysis on a Coulter GEN*S (125 smears) were used as reference methods. The quality of collection of samples and laboriousness were additionally assessed. The certified MECOS-Ts2 subsystems were additionally used as reference tools. The tests indicated the advantage of computer-aided MECOS-Tsl2 complex microscopy over manual microscopy.

Adolescent↗

[Automatic erythrocytometry in a robotized microscope MEKOS-Ts1].

Measurements of the form and size of erythrocytes are needed in the diagnosis of a number of diseases. However, such measurements, if made manually, are a labor-consuming and often inaccurate method, which ensures the determination of a very limited number of parameters. Hardware/software unit MEKOS-C1 enables an automated examination of blood smear, thus speeding up significantly the analysis and ensuring a more complete and accurate information. The possibilities of unit MEKOS-C1 were evaluated for the diagnosis of ovalocytosis. Blood smears of 19 patients from the Russian Pediatric Clinical Hospital, including 8 patients with inherited ovalocytosis, 1 patient with spherocytic ovalocytosis and 10 patients without the disease, were made use of Erythrocytes were isolated in the images of preparations and the contour of each cell was approximated by ellipse. The ratio between ellipse semi-axes served as a measure of erythrocytes' ovality. The mean ratio of semi-axes (RS) and the index of ovalocytosis (IO), i.e. a ratio of the mean maximum diameter to the mean minimal diameter, were calculated for each smear. Manual IO measurements were made in all preparations as a control. Since an additional error can enter the result because of the irregular smear nature and impossibility to standardize completely the technology of smear preparation, the data, obtained from two different smear parts and from parallel preparations, were compared. The reliability, stability and good reproducibility of the automated measurement results were demonstrated. The mean erythrocytes' RS correlated well with IO, obtained manually, and did not virtually differ from RS, measured in the automated manner. The mean RS value of erythrocytes, obtained from patients with inherited ovalocytosis, significantly differed from the control values, which is indicative of a high information density of the discussed parameter. Therefore, RS, when measured automatically, is a reliable and convenient characteristic of erythrocytes' ovality under the conditions of using the ordinary technique of smear preparation.

Adolescent↗

[Quantitative morphology of periferal erythrocytes and bone marrow erythrokaryocytes in acute leukemia and hemopoietic depressions].

Morphology of peripheral blood erythrocytes was studied in patients with acute leukemia and aplastic anemia by a Russian cytoanalyzer Mekos-C. Twenty-eight patients with acute myeloblastic leukemia, 15 with acute lymphoblastic leukemia, and 11 with aplastic anemia were examined. Erythrocytes (n = 500) were examined in fixed non-stained blood smears. Hemoglobin content and morphometric parameters of each cell were studied and automatic classification of cells was carried out. The data of computer morphodensitometry are compatible with the data of cytochemical studies of the bone marrow erythroid cells (PAS reaction after McManus). The results indicate circulation of erythrocyte subpopulations differing by shape and other signs (hemoglobin content, section area, shape factor) in the blood of patients with acute leukemia and aplastic anemia. The share of pathological erythrocytes in the peripheral blood reflects failure of erythropoiesis.

Acute Disease↗

[Automated cytophotomorphometric tests of blood smears in general clinical studies and population screening].

Automation of routine operations of photomorphometry of blood smears realized in the MEKOS-C cytoanalyzer helped create a new level of using a set of cytological tests, such as assessment of the leukocyte and erythrocyte formulae and of the histogram of hemoglobin distribution in red cells, estimation of leukocyte subtypes, assessment of the characteristics of the nucleolar system and the nucleoli-forming sites. Automated complex analysis of an increase in the measured characteristics of red and white blood cells impossible in common microscopy and flow cytoanalyzers appreciably improves the sensitivity and accuracy of tests and extends the range of their application. Low cost of analysis of a blood smear permits the use of MEKOS-C not only in clinical studies, but even in overall prophylactic screenings of the population.

Automation↗

[Analysis of erythrocytes in the MEKOS-C system].

Quantitative cytofluorimetric analysis of red cells by the MEKOS-C device provides complete information about peripheral blood erythrocytes, which cannot be obtained by other methods and equipment. An analysis is cheap and sensitive, this recommending it for practical hematology, toxicology, and narcology. The MEKOS-C device permits the preclinical diagnosis of a number of diseases and monitoring their treatment. The device is cheap and available for therapeutic and diagnostic institutions of all levels.

Adolescent↗

[An automated microscopy system MECOS-Ts2 and its trial use for blood and bone-marrow smear analysis].

Disadvantages of conventional procedures for testing of medical automated microscopy systems are considered. A testing procedure based on step-by-step testing of the system units is suggested. The procedure makes use of remote data analysis through communication lines. The structure of MECOS-Ts2 automated microscopy system and the procedure for its testing are considered.

Blood Cells↗

[Automated MECOS-Ts2 microscopy complex in pathologoanatomic practice].

Computer-aided and information systems of a MECOS-Ts2 microscopy complex designed to transmit a representative image of a specimen along communication lines are considered. The above systems allow the use of the complex: 1) in on-line and off-line modes to provide tele-medical services (cytology, histology, etc.); moreover, the requirements for channel traffic may be decreased over and over again as compared to the routine on-line videomicroscopy mode; 2) for telemedical tests of specialized local automatic procedures of microscopical analysis (analysis of smears of blood and bone-marrow smears, parasitological analysis, etc.); 3) for collection of a representative electronic archive of the "virtual" specimens of rare nosological entities, which have been obtained in different medical institutions, w hich will provide valid statistical assessments of diagnostic decisions; 4) for remote accompaniment of MECOS-Ts2 complexes by the manufacture (update of versions, training, quality control of sample preparation, collection of commission statistics); 5) for training and certification of remote laboratory staff. The functions considered cannot be implemented in analyzers of other types, in flow analyzers, in particular.

Humans↗

[Fluctuations of the electrical characteristics of a membrane in stress states].

The general scheme of calculation of current and voltage fluctuations obtained in [4] was applied to the definite theoretical membrane model based on the experimental data. Spectra for the extreme conditions of current and voltage fixation were obtained. The estimation of some parameters of the theory was carried out.

Biophysical Phenomena↗

[Electrostriction of vesicular membranes].

Methods for consideration of membrane electrostriction existing in literature are critically analysed. Two cases of electrostriction are dealt with: the membrane is closed (vesicles), the membrane exchanges molecules with reservoir (BLM with meniscus). Deformations and elastic forces arising in uncharged vesicle with the constant number of particles when the electrostatic potential difference is applied across the membrane are calculated.

Biophysical Phenomena↗