PubMed Health⌕ Search

Biomedical subjects

A M Sawyer-Glover

Publications and source records attributed to A M Sawyer-Glover.

9 recordsLinked to original sources

Early life stress and inherited variation in monkey hippocampal volumes.

BACKGROUND: Opportunities for research on the causes and consequences of stress-related hippocampal atrophy are limited in human psychiatric disorders. Therefore, this longitudinal study investigated early life stress and inherited variation in monkey hippocampal volumes. METHODS: Paternal half-siblings raised apart from one another by different mothers in the absence of fathers were randomized to 1 of 3 postnatal conditions that disrupted diverse aspects of early maternal care (n = 13 monkeys per condition). These conditions were previously shown to produce differences in social behavior, emotional reactivity, and neuroendocrine stress physiology. Hippocampal volumes were subsequently determined in adulthood by high-resolution magnetic resonance imaging. RESULTS: Adult hippocampal volumes did not differ with respect to the stressful postnatal conditions. Based on paternal half-sibling effects, the estimated proportion of genetic variance, ie, heritability, was 54% for hippocampal size. Paternal half-siblings with small adult hippocampal volumes responded to the removal of all mothers after weaning with initially larger relative increases in cortisol levels. Plasma cortisol levels 3 and 7 days later, and measures of cortisol-negative feedback in adulthood were not, however, correlated with hippocampal size. CONCLUSIONS: In humans with mood and anxiety disorders, small hippocampal volumes have been taken as evidence that excessive stress levels of cortisol induce hippocampal volume loss. Results from this study of monkeys suggest that small hippocampi also reflect an inherited characteristic of the brain. Genetically informed clinical studies should assess whether inherited variation in hippocampal morphology contributes to excessive stress levels of cortisol through diminished neuroendocrine regulation.

Animals↗

Characterization of breast lesion morphology with delayed 3DSSMT: an adjunct to dynamic breast MRI.

The purpose of the study was to determine the sensitivity and specificity of various morphologic criteria in distinguishing malignant from benign breast lesions using a new sequence (3DSSMT) performed immediately after dynamic breast MRI. 3DSSMT combines a water-selective spectral-spatial excitation and an on-resonance magnetization transfer pulse with three-dimensional spoiled gradient-echo imaging. Morphologic features of 87 pathologically confirmed lesions were analyzed. The presence of either skin thickening, or a combination of a spiculated or microlobulated border, with a rim, ductal, linear, or clumped enhancement pattern was 94% specific and 54% sensitive for malignancy. Conversely, the presence of either a perfectly smooth border, a well-defined margin, non-enhancing internal septations, or a macrolobulated border was 97% specific and 35% sensitive for a benign diagnosis. In conclusion, delayed 3DSSMT discriminates a significant number of benign and malignant breast lesions; it has the potential to improve the diagnostic accuracy of dynamic breast MRI.

Breast↗

Dynamic breast MRI with spiral trajectories: 3D versus 2D.

A three-dimensional (3)D spiral sequence was developed for dynamic breast magnetic resonance (MR) imaging with much improved image quality. Partial Z phase encoding was applied to obtain thinner slices for a coverage of the whole breast. Comparison between the 3D and a previously developed multi-slice 2D spiral sequences was performed on ten healthy volunteers without contrast and five breast patients with gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA). The 3D spiral images had significantly less off-resonance blurring and spiral artifacts. With a small compromise on temporal resolution (7.7 seconds in 2D and 10.6 seconds in 3D), we obtained 32 interpolated 3-5 mm slices (with 20 Z phase encodes) for a full coverage of 10-16 cm breast with the same 1 x 1 mm2 in-plane resolution as the 2D sequence, which had 12 8-13 mm slices. Contrast between glandular and soft tissue in normal breasts was increased by about 25%. The reduced repetition time in the 3D spiral acquisition led to an increased Gd-enhanced signal. The difference between the enhancement of malignant and benign lesions increased by sevenfold. We expect that this new development could lead to improved specificity in characterizing breast lesions using MR imaging.

Adult↗

Pre-MRI procedure screening: recommendations and safety considerations for biomedical implants and devices.

Maintaining a safe MR environment is a daily challenge for MR healthcare workers, especially in consideration of the increasing number of clinical MR applications and the large and growing variety of biomedical implants and devices that are currently used in patients. This review article presents policies and procedures that should be used to screen all patients and individuals before allowing them to enter the magnetic resonance (MR) environment. Information pertaining to MR safety and the relative risk factors for implants, devices and materials is discussed. A comprehensive pre-MRI procedure screening form that is recommended for use by MR facilities is also included.

Equipment Design↗

Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound.

The objective of this study was to evaluate the relative efficacies of magnetic resonance (MR) imaging, ultrasonography, and mammography in implant rupture detection and to illustrate pitfalls in MR image interpretation. Thirty patients referred by plastic surgeons with suspected breast implant rupture were prospectively evaluated using MR, ultrasonography, and mammography. Imaging examinations were interpreted independently and blindly for implant rupture and correlated to operative findings. Surgical correlation in 16 patients (53 percent) with 31 implants showed 13 (42 percent) were intact, 5 (16 percent) had severe gel bleed, and 13 (42 percent) were ruptured. MR sensitivity was 100 percent and specificity was 63 percent. Accuracy for rupture was 81 percent with MR, higher than with ultrasonography and mammography (77 and 59 percent, respectively). We describe a specific pitfall in MR interpretation, the "rat-tail" sign, composed of a medial linear extension of silicone along the chest wall. Seen in eight cases (four intact, three ruptures, one gel bleed), the rat-tail sign may lead to misdiagnosis of implant rupture if seen in isolation. Magnetic resonance imaging is more accurate and sensitive than ultrasonography and mammography in detecting breast implant rupture. We describe a new sign (rat-tail sign) composed of medial compression of the implant simulating silicone extrusion as a potential false-positive MR finding for rupture. This article presents clinical experience with magnetic resonance, mammography, and ultrasound in the diagnosis of implant rupture and defines and illustrates potential pitfalls of MR interpretation, including the new rat-tail sign.

Adult↗

Breast lesion localization: a freehand, interactive MR imaging-guided technique.

PURPOSE: To evaluate interactive magnetic resonance (MR) imaging-guided preoperative needle localization and hookwire placement in the noncompressed breast in patients in the prone position. MATERIALS AND METHODS: Nineteen MR imaging-guided breast lesion localization procedures were performed in 17 patients aged 38-70 years (mean age, 48 years) by using an open-platform breast coil in either a 1.5-T, closed-bore imager (n = 14) or a 0.5-T, open-bore imager (n = 5). Rapid imaging (fast spin-echo, water-selective fast spin-echo, or water-specific three-point Dixon gradient-echo) was alternated with freehand manipulation of an MR-compatible needle to achieve accurate needle placement. RESULTS: Up to three manipulations of the needle were required during an average of 9 minutes to reach the target lesion. MR imaging findings confirmed the final needle position within 9 mm of the target in all cases. The accuracy of 10 localizations was independently corroborated either at mammography or at ultrasonography. Nine lesions were visible on MR images only. CONCLUSION: Interactive MR imaging-guided, freehand needle localization is simple, accurate, and requires no special stereotactic equipment. Lesions throughout the breast, including those in the anterior part of the breast and those near the chest wall, which can be inaccessible with standard grid or compression-plate techniques, can be localized. A variety of needle trajectories in addition to the horizontal path are possible, including circumareolar approaches and tangential needle paths designed to avoid puncture of implants.

Adult↗

Breast disease: dynamic spiral MR imaging.

PURPOSE: To compare various subjective, empiric, and pharmacokinetic methods for interpreting findings at dynamic magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS: Dynamic spiral breast MR imaging was performed in 52 women suspected of having or with known breast disease. Gadolinium-enhanced images were obtained at 12 locations through the whole breast every 7.8 seconds for 8.5 minutes after bolus injection of contrast material. Time-signal intensity curves from regions of interest corresponding to 57 pathologically proved lesions were analyzed by means of a two-compartment pharmacokinetic model, and the diagnostic performance of various parameters was analyzed. RESULTS: Findings included invasive carcinoma in 17 patients, isolated ductal carcinoma in situ (DCIS) in six, and benign lesions in 34. Although some overlap between carcinomas and benign diagnoses was noted for all parameters, receiver operating characteristic analysis indicated that the exchange rate constant had the greatest overall ability to discriminate benign and malignant disease. The elimination rate constant and washout were the most specific parameters. The exchange rate constant, wash-in, and extrapolation point were the most sensitive parameters. DCIS was not consistently distinguished from benign disease with any method. CONCLUSION: Dynamic spiral breast MR imaging proved an excellent method with which to collect contrast enhancement data rapidly enough that accurate comparisons can be made between many analytic methods.

Breast↗

Three-dimensional shaded-surface rendering of MR images of the breast: technique, applications, and impact on surgical management of breast disease.

Contrast material-enhanced magnetic resonance (MR) imaging is reported to be the most accurate modality for determining the extent of breast cancer before surgery. Three-dimensionally rendered MR images can be used as an adjunct in planning breast surgery. Semiautomated methods are used to isolate the breast tissue within high-resolution MR images and to render the skin with a shaded-surface method. Cut-away views reveal lesions in the interior of the breast. Cut-plane shaded-surface display provides the surgeon with information on the size, extent, and spatial relationships of a breast lesion in a simple, intuitive format. This technique can help the surgeon plan a breast biopsy, lumpectomy, or mastectomy that will maximize local control of breast cancer while minimizing cosmetic damage to the unaffected portions of the breast. In a review of 15 clinical cases, cut-plane shaded-surface rendering aided surgical planning in 10 cases.

Adult↗

Intensity-modulated parametric mapping for simultaneous display of rapid dynamic and high-spatial-resolution breast MR imaging data.

Contrast material-enhanced magnetic resonance (MR) imaging of the breast has variable specificity for differentiation of breast cancer from other enhancing conditions. Two principal strategies to improve its specificity are rapid dynamic MR imaging and high-spatial-resolution MR imaging. A method was developed of combining contemporaneously acquired dynamic and high-spatial-resolution MR imaging data into a single integrated display. Whole-breast rapid dynamic data were condensed into a color map by using pharmacokinetic analysis. The pharmacokinetic results were combined with the high-spatial-resolution images with a new technique that preserves underlying morphologic details. This new method was evaluated by five radiologists for eight breast lesions, and the results were compared with those of the standard method of overlaying parametric map data. The radiologists' ratings showed a statistically significant preference for the intensity-modulated parametric map display method over the overlaid parametric display method for 10 of the 12 evaluation criteria. The new method enabled simultaneous visualization of pharmacokinetic and morphologic information, facilitated assessment of lesion extent, and improved the suppression of noise in the pharmacokinetic data. The ability to simultaneously assess both dynamic and high-spatial-resolution features may ultimately improve the specificity of breast MR imaging.

Breast Neoplasms↗