PubMed Health⌕ Search

Biomedical subjects

A M de Beus

Publications and source records attributed to A M de Beus.

2 recordsLinked to original sources

A gastric acid secretion model.

A theory of gastric acid production and self-protection is formulated mathematically and examined for clinical and experimental correlations, implications, and predictions using analytic and numerical techniques. In our model, gastric acid secretion in the stomach, as represented by an archetypal gastron, consists of two chambers, circulatory and luminal, connected by two different regions of ion exchange. The capillary circulation of the gastric mucosa is arranged in arterial-venous arcades which pass from the gastric glands up to the surface epithelial lining of the lumen; therefore the upstream region of the capillary chamber communicates with oxyntic cells, while the downstream region communicates with epithelial cells. Both cell types abut the gastric lumen. Ion currents across the upstream region are calculated from a steady-state oxyntic cell model with active ion transport, while the downstream ion fluxes are (facilitated) diffusion driven or secondarily active. Water transport is considered iso-osmotic. The steady-state model is solved in closed form for low gastric lumen pH. A wide variety of previously performed static and dynamic experiments on ion and CO2 transport in the gastric lumen and gastric blood supply are for the first time correlated with each other for an (at least) semiquantitative test of current concepts of gastric acid secretion and for the purpose of model verification. Agreement with the data is reported with a few outstanding and instructive exceptions. Model predictions and implications are also discussed.

Animals↗

Design optimization of a prosthesis stem reinforcing shell in total hip arthroplasty.

The use of a perforated, titanium funicular shell to support the proximal femoral cortex in total hip arthroplasty was evaluated with the aid of both analytical and numerical techniques. The principal interactions between the femoral cortex, the metal shell, the implant stem and the acrylic bone cement were modeled using beam on elastic foundations theory and two-dimensional elasticity theory. Subsequent formulation of this model as a nonlinear design optimization problem enabled the determination of the dimensions of the implant and reinforcing shell which minimized an objective function based on a simplified material failure criterion. Two cases were examined, each with two cervico-diaphyseal angles: case A: with a rigid contact between a proximal prosthesis collar and the calcar femorale and case B: no collar contact (a collarless prosthesis or post-operative loosening). Case A achieved an optimal solution at a stem diameter 11-23 percent of the cortex inner diameter, a stem length to diameter ratio of 12-40, shell diameter 22-53 percent and thickness 0.2-7.2 percent of the cortex inner diameter and thickness, respectively. Case B achieved an optimal solution at a stem diameter 67-92 percent of the cortex inner diameter, length to diameter ratio of 4-6, and no shell. In case A the collar support makes the type of internal fixation unimportant, while in the more realistic case B, the shell is not recommended.

Elasticity↗