A comparison of three algorithms for chromatograms alignment.

In this paper the performance of three alignment algorithms, correlation optimized warping, parametric time warping and semi-parametric time warping, is compared on real chromatograms. Among these, parametric time warping is the simplest and fastest; generally less than 1s is required to align two chromatograms. It does not require the optimization of input parameters and allows the alignment of peak shifts in only one direction, or non-complex peak shifts in both directions. With correlation optimized warping and semi-parametric time warping complex peak shifts in both directions can be corrected but at the expense of the optimization of two input parameters. Semi-parametric time warping requires the selection of the proper number of B-splines in the warping function and, if necessary, the optimization of the penalty parameter. Often the default values can be used to obtain aligned signals. The optimization of the input parameters for correlation optimized warping (section length, slack) is not easy and time-consuming. Moreover, dependent on the input parameters, the computation time of the correlation optimized warping algorithm can be twice as long as for semi-parametric time warping for which computation times up to 23 s are required. However, the performance of both algorithms is equally good considering the improvement of the precision of the peak retention times and correlation coefficients between the chromatograms, after alignment. For the data aligned in this study, the average retention time precision and the lowest correlation before warping were 14 and 0.17, and were improved to three and 0.83, and six and 0.87 after warping, with correlation optimized warping and semi-parametric time warping, respectively.

Algorithms↗

Chemometric treatment of vanillin fingerprint chromatograms. Effect of different signal alignments on principal component analysis plots.

This study describes the chemometric treatment of vanillin fingerprint chromatograms to distinguish vanillin from different sources. Prior to principal component analysis, which is used to discriminate vanillin from different origins, the fingerprints are aligned. Three alignment algorithms are tested, correlation optimized warping (COW), target peak alignment (TPA) and semi-parametric time warping (STW). The performance of the three algorithms is evaluated and the effect of the different alignments on the PCA score plots is investigated. The alignment obtained with STW differs somewhat from that with COW and TPA. However, equivalent score plots were obtained regarding the different vanillin groups.

Algorithms↗

Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals part I: peak detection.

A series of two papers describing a procedure for automated peak deconvolution is presented. The goal is to develop a package of routines that can be used by non-experienced users. Part I (this paper) concerns peak detection, whereas Part II is dedicated to the deconvolution itself. In this first part, the most interesting features of the peak detection algorithms, which precede the deconvolution step, are outlined. High-order derivatives provide valuable information to assess the number of underlying compounds under a given peak cluster. A smoothing technique was found essential to compute properly the derivatives, since the noise is amplified when differences are calculated. The Savitsky-Golay smoother was applied in combination with the Durbin-Watson criterion to automate the window size selection. This strategy removed the noise without loosing valuable information. In some cases, it was found preferable to split the chromatogram in different elution regions, and apply the Durbin-Watson test and the Savitsky-Golay smoother to each region, separately. The derivatives allowed obtaining estimates of both peak parameters and the corresponding ranges for each eluting compound to be used in the deconvolution. An algorithm oriented to compare peaks from different chromatograms is also presented to perform deconvolution, using information from several related chromatograms.

Algorithms↗

Development of a ginkgo biloba fingerprint chromatogram with UV and evaporative light scattering detection and optimization of the evaporative light scattering detector operating conditions.

A fingerprint chromatogram of a standardized Ginkgo biloba extract is developed on a monolithic silica column using a ternary gradient containing water, iso-propanol and tetrahydrofuran. For the detection, UV and evaporative light scattering (ELS) detectors are used, the latter allowing detection of the poor UV absorbing compounds as ginkgolides (A-C and J) and bilobalide in the extract. The complementary information between the UV and ELS fingerprint is evaluated. The ELS detector used in this study can operate in an impactor 'on' or 'off' mode. For each mode, the operating conditions such as the nebulizing gas flow rate, the drift tube temperature and the gain are optimized by use of three-level screening designs to obtain the best signal-to-noise (S/N) ratio in the final ELS fingerprint chromatogram. In both impactor modes, very similar S/N ratios are obtained for the nominal levels of the design. However, optimization of the operating conditions resulted, for both impactor modes, in a significant increase in S/N ratios compared to the initial evaluated conditions, obtained from the detector software.

Chromatography, High Pressure Liquid↗

Prediction of total green tea antioxidant capacity from chromatograms by multivariate modeling.

In this paper, a fast strategy for determining the total antioxidant capacity of Chinese green tea extracts is developed. This strategy includes the use of experimental techniques, such as fast high-performance liquid chromatography (HPLC) on monolithic columns and a spectrophotometric approach to determine the total antioxidant capacity of the extracts. To extract the chemically relevant information from the obtained data, chemometrical approaches are used. Among them there are correlation optimized warping (COW) to align the chromatograms, robust principal component analysis (robust PCA) to detect outliers, and partial least squares (PLS) and uninformative variable elimination partial least squares (UVE-PLS) to construct a reliable multivariate regression model to predict the total antioxidant capacity from the fast chromatograms.

Antioxidants↗

Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals part II: peak model and deconvolution algorithms.

Several interlinked algorithms for peak deconvolution by non-linear regression are presented. These procedures, together with the peak detection methods outlined in Part I, have allowed the implementation of an automatic method able to process multi-overlapped signals, requiring little user interaction. A criterion based on the evaluation of the multivariate selectivity of the chromatographic signal is used to auto-select the most efficient deconvolution procedure for each chromatographic situation. In this way, non-optimal local solutions are avoided in cases of high overlap, and short computation times are obtained in situations of high resolution. A new algorithm, fitting both the original signal and the second derivatives is proved to avoid local optima in intermediate coelution situations. This allows achieving the global optimum without the need of background knowledge by the user. A previously reported peak model, a Gaussian with a polynomial standard deviation whose complexity can be modulated to enhance the fitting quality, was applied. However, the original formulation was modified to account baseline outside the peak region. Also, the optimal model complexity was auto-selected via error propagation theory. The method is able to process simultaneously several related chromatograms. The software was tested with both simulated and experimental chromatograms obtained with monolithic silica columns.

Algorithms↗

Fast separations on monolithic silica columns: method transfer, robustness and column ageing for some case studies.

Six separation methods, developed on conventional silica high performance liquid chromatography (HPLC) columns were transferred to monolithic silica columns of 5 and 10 cm length. The transferred methods include the separation of an alkylbenzene mixture, the separations of drugs from their impurities (nimesulide, tetracycline, phenoxymethylpenicillin and erythromycin) and the separation of a green tea extract. The transfer of the first three methods was successful while for the latter three it was not. Increasing the flow rate up to 9 ml/min (where possible) inversely decreased the analysis time of the successfully transferred methods to 48 s (alkylbenzene mixture) 1.8 min (nimesulide mixture) and 3 min (tetracycline mixture) while still reasonable well separated peaks were obtained. The robustness and repeatability of the transferred and accelerated separations was found to be acceptable. Despite the use of flow rates up to 9 ml/min and frequent mobile phase changes with pH values varying from 3.5 to 7, the column performance was found to be rather constant and the column ageing to be minimal.

Chromatography, High Pressure Liquid↗