Near-infrared Raman spectroscopy for in vitro detection of cervical precancers.

In this study, we investigate the potential of near-infrared Raman spectroscopy to differentiate cervical precancers from normal tissues, inflammation and metaplasia and to differentially diagnose low-grade and high-grade precancers. Near infrared Raman spectra were measured from 36 biopsies from 18 patients in vitro. Detection algorithms were developed and evaluated relative to histopathologic examination. Algorithms based on empirically selected peak intensities, ratios of peak intensities and a combination of principal component analysis for data reduction and Fisher discriminant analysis for classification were investigated. Spectral peaks were tentatively identified from measured spectra of potential chromophores. Empirically selected normalized intensities can differentiate precancers from other tissues with an average sensitivity and specificity of 88 +/- 4% and 92 +/- 4%. Ratios of unnormalized intensities can differentiate precancers from other tissues with a sensitivity and specificity of 82% and 88% and high-grade from low-grade lesions with a sensitivity and specificity of 100%. Using multivariate methods, intensities at eight frequencies can be used to differentiate precancers from all other tissues with a sensitivity and specificity of 82% and 92% in an unbiased test. Raman algorithms can potentially separate benign abnormalities such as inflammation and metaplasia from precancers. Comparison of tissue spectra to published and measured chromophore spectra indicate that the most likely primary contributors to the tissue spectra are collagen, nucleic acids, phospholipids and glucose 1-phosphate. These results suggest that near-infrared Raman spectroscopy can be used for cervical precancer diagnosis and may be able to accurately separate samples with inflammation and metaplasia from precancer.

Cervix Uteri

Development of a fiber optic probe to measure NIR Raman spectra of cervical tissue in vivo.

The goal of this study was to develop a compact fiber optic probe to measure near infrared Raman spectra of human cervical tissue in vivo for the clinical diagnosis of cervical precancers. A Raman spectrometer and fiber optic probe were designed, constructed and tested. The probe was first tested using standards with known Raman spectra, and then the probe was used to acquire Raman spectra from normal and precancerous cervical tissue in vivo. Raman spectra of cervical tissue could be acquired in vivo in 90 s using incident powers comparable to the threshold limit values for laser exposure of the skin. Although some silica signal obscured tissue Raman bands below 900 cm-1, Raman features from cervical tissue could clearly be discerned with an acceptable signal-to-noise ratio above 900 cm-1. The success of the Raman probe described here indicates that near infrared Raman spectra can be measured in vivo from cervical tissues. Increasing the power of the excitation source could reduce the integration time to below 20 s.

Biopsy

Cervical precancer detection using a multivariate statistical algorithm based on laser-induced fluorescence spectra at multiple excitation wavelengths.

A portable fluorimeter was developed and utilized to acquire fluorescence spectra from 381 cervical sites in 95 patients at 337, 380 and 460 nm excitation immediately prior to colposcopy. A multivariate statistical algorithm was used to extract clinically useful information from tissue spectra acquired in vivo. Two full-parameter algorithms were developed using tissue fluorescence emission spectra at all three excitation wavelengths (161 excitation-emission wavelength pairs) for cervical precancer (squamous intraepithelial lesion [SIL]) detection: a screening algorithm that discriminates between SIL and non-SIL with a sensitivity of 82 +/- 1.4% and specificity of 68 +/- 0.0%, and a diagnostic algorithm that differentiates high-grade SIL from non-high-grade SIL with a sensitivity and specificity of 79 +/- 2% and 78 +/- 6%, respectively. Multivariate statistical analysis was also employed to reduce the number of fluorescence excitation-emission wavelength pairs needed to redevelop algorithms that demonstrate a minimum decrease in classification accuracy. Two reduced-parameter algorithms that employ fluorescence intensities at only 15 excitation-emission wavelength pairs were developed: the screening algorithm differentiates SIL from non-SIL with a sensitivity of 84 +/- 1.5% and specificity of 65 +/- 2% and the diagnostic algorithm discriminates high-grade SIL from non-high-grade SIL with a sensitivity and specificity of 78 +/- 0.7% and 74 +/- 2%, respectively. Both the full-parameter and reduced-parameter screening algorithms discriminate between SIL and non-SIL with a similar specificity (+/-5%) and a substantially improved sensitivity relative to Pap smear screening. A comparison of the full-parameter and reduced-parameter diagnostic algorithms to colposcopy in expert hands indicates that all three have a very similar sensitivity and specificity for differentiating high-grade SIL from non-high-grade SIL.

Algorithms