PubMed Health⌕ Search

Biomedical subjects

A Mahnken

Publications and source records attributed to A Mahnken.

8 recordsLinked to original sources

[First results with catheter and magnetically guided and detached polymerized ferromagnetic particle filaments and heat-induced particle release using the Stereotaxis Niobe system].

PURPOSE: To develop a new technique for intravascular guidance and the release of magnetized ferromagnetic nanoparticles using a polymerized filament by means of an external magnetic field. MATERIALS AND METHODS: Ferromagnetic nanoscaled beads were embedded in temperature-sensitive gels to form filaments after polymerization. Deflection of the filaments was assessed in a Stereotaxis Niobe magnetic navigation system (MNS) in comparison with dedicated guide wires. The curvature was measured as a surrogate parameter for deflection. In combination with commercially available catheters, the filaments were navigated in a perfused aneurysmatic vessel model and a perfused branched vessel model under the influence of two permanent magnets of the Niobe MNS. The magnetic field vector was varied in all three dimensions. After positioning, the magnetic colloid-containing filaments were exposed to an electromagnetic field of 45 kA/m, 200 kHz for a period of 5 minutes for non-invasive heating. RESULTS: The filaments showed superior deflectability compared to the dedicated guide wires (p = 0.0091). The curvature was 0.54 +/- 0.12 mm(-1) for the filaments and 0.33 +/- 0.21 mm(-1) for the guide wires. In combination with angiography catheters, magnetic guidance and accumulation of specially designed filaments were possible in the perfused vessel model. Inductive heating allowed non-invasive disintegration and releasing of the nanoparticles in all filaments. CONCLUSION: This feasibility study shows that magnetic guidance and targeting of a specially designed magnetic colloid-containing filament and subsequent disintegration are feasible. This technique offers the potential for controlled local drug release.

Aneurysm↗

[Dose-reduced 16-slice multidetector-row spiral computed tomography in children with bronchoscopically suspected vascular tracheal stenosis -- initial results].

PURPOSE: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis. MATERIALS AND METHODS: 12 children (4 days to 3 years, 1.2 - 13.5 kg body weight) were examined using i. v. contrast-enhanced 16-slice MDCT (SOMATOM Sensation 16, Forchheim, Germany) without breath-hold and under sedation (11/12). All MDCTs were performed with a dose reduction. The beam collimation was 16 x 0.75 mm, except in the case of one child. MPRs along the tracheal axis in the x-, y- and z-directions and volume-rendering-reconstructions (VRTs) were calculated based on a secondary raw data set in addition to conventional axial slices. 2 radiologists used a three-point grade scale to evaluate the image quality, motion, and contrast media artifacts as well as the usefulness of the 2D- and 3D-reconstructions for determining the diagnosis. Statistical analysis was performed on the basis of a Kappa test. RESULTS: In all cases the cause of the fiberoptic bronchoscopically suspected tracheal stenosis was revealed: compression due to the brachiocephalic trunk (n = 7), double aortic arch (n = 2), lusorian artery (n = 1), vascular compression of the left main bronchus (n = 2). In 3 patients further thoracic anomalies, such as tracheobronchial (n = 2), and vascular (n = 2) and vertebral (n = 1) anomalies were found. The attenuation in the anomalous vessels was 307 +/- 140 HU. The image noise was 9.8 +/- 1.9 HU. The mean dose reduction was 82.7 +/- 3.2 % compared to a standard adult thoracic CT. All examinations were rated as diagnostically good (median 1, range 1, k = 1). 3D images did not show any stair artifacts (median 2, range 1 - 2, k = 1). The image noise was minor to moderate and hardly any motion artifacts were seen (median 1, range 1 - 2, k = 0.8). Contrast media artifacts were rated zero to minor (median 1.5, range 1 - 2, k = 0.676). MPRs (median 1, range 1, k = 1) and VRTs (median 1, range 1, k = 1) were found to be useful for diagnosis. Subsequent vascular surgery was performed on 8 patients. CONCLUSION: Contrast-enhanced dose-reduced 16-slice MDCT is effective for demonstrating the cause of fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis even in very small and severely ill children despite the small contrast media amount and free breathing.

Airway Obstruction↗

[16-Row multidetector CT of the pelvis after iliosacrally inserted osteosynthetic screws: experimental study of dose adjustment on preserved human cadaver specimens].

PURPOSE: The study was performed to assess the necessity of dose adjustment (kV or mAs (eff.)) in 16-slice CT (MDCT) in postoperative controls of iliosacrally inserted osteosynthetic screws (OS) on preserved human cadaver specimens. The minimal tube settings for diagnostic imaging of the pelvic bone were analyzed and the effective doses and important organ doses were calculated. MATERIALS AND METHODS: 16 preserved human cadaver specimens with transiliac osteosynthetic screws were scanned on a 16-slice CT (collimation 16 x 0.75 mm, pitch 0.7) with 10 different tube settings (35, 50, 75, 100, 150 mAs (eff.) and 120 and 140 kV). 32 datasets (blinded for name and scan parameters) with and without OS were independently evaluated by four observers. The 10 series were sorted by subjective image quality (image noise, contours, artifacts), and the series with the lowest but still diagnostic quality was selected. The statistical analysis included multi-rater-kappa-test and Wilcoxon test for paired samples. RESULTS: The multi-reader agreements for sorting the series were fair (kappa = 0.38). The agreements in comparing the lowest diagnostic image qualities were slight to fair (kappa = 0.08-0.23). The paired sample test comparing the lowest diagnostic image quality with and without OS showed no statistical significance (p = 0.29). 87.5 % of the readouts (n = 64 [16 examinations, 4 readers]) with OS and 78.1 % of those without OS could be adequately diagnosed using the three series with the lowest effective doses (0.9-1.4 mSv for men, 1.4-2.0 mSv for women; 120 kV-35 mAs (eff.), 120-50, 140-35). CONCLUSION: MSCT scans of the pelvic bone can be performed with very low effective doses. It is not necessary to adjust tube settings when imaging bones with osteosynthetic screws. If the concept for the control of the pelvic osteosynthetic screw position includes more than 2 conventional films (for example anterioposterior view with additional inlet and outlet views), a low dose CT is preferable to conventional radiography.

Animals↗

Multipolar radiofrequency ablation: first clinical results.

Common systems of radiofrequency ablation (RFA) are monopolar devices which require grounding pads on the thighs in order to close the electrical circuit. Bipolar RFA does not require grounding pads, because both electrodes are located on one probe and alternating current circuit is confined within the target tissue. In this paper we report on the first clinical application of a new ablation device which enables both, bipolar (1 probe) and multipolar (up to 3 internally cooled probes simultaneously) radiofrequency ablation. We report on bi- and multipolar applications in liver tumors (9 patients), osteoid osteoma (2 patients) and renal cell cancer (1 patient).

Adult↗

[Left ventricular functional parameters using ECG-gated multidetector spiral CT in comparison with invasive ventriculography].

PURPOSE: To evaluate the accuracy of left ventricular function using a multidetector CT (MDCT) with retrospective ECG-gating and to compare the results with conventional ventriculography. MATERIALS AND METHODS: In 26 patients, retrospectively ECG-gated MDCT of the heart (Volume Zoom, Siemens, Germany) as well as conventional coronary angiography including ventriculography was performed to exclude or follow coronary artery disease. CT examination (120 KV, 400 mAs) was carried out with 4 x 1 mm collimation (500 ms gantry rotation time). For CT angiography, 150 ml of contrast media was injected intravenously at a flow rate of 4 ml/s. All data sets of the functional cardiac parameters were reconstructed in end-systolic and end-diastolic phase. End-systolic volume (ESV), end-diastolic volume (EDV) and ejection fraction (EF) were determined from multiplanar reformations orthogonally through the cardiac short axis and analyzed using special evaluation software (ARGUS, Siemens). The results were compared with ESV, EDV and EF obtained from invasive ventriculography. RESULTS: In all cases, a sufficient quality of the MDCT images was achieved. EDV (150.1 +/- 16.2 ml MDCT vs. 138.7 +/- 16.9 ml ventriculography; mean difference 11.4 +/- 12.7 ml; r = 0.51) had an acceptable correlation to conventional ventriculography, and ESV (58.1 +/- 14.6 ml vs. 50.2 +/- 13.4 ml; mean difference 7.9 +/- 8.8 ml; r = 0.81) and EF (60.9 +/- 13.6 % vs. 64.9 +/- 12.7 %; mean difference 4.0 +/- 6.2 %; r = 0.79) showed a good correlation. In comparison with invasive ventriculography, MDCT tended to overestimate significantly EDV (p = 0.008) and ESV (p = 0.003) and to underestimate EF (p = 0.001). CONCLUSION: MDCT of the heart with retrospective ECG-gating enables efficient estimation of left ventricular function, providing important additional information of non-invasive cardiac imaging using MDCT. However, EDV and EVS were significantly overestimated and EF was underestimated in MDCT compared to ventriculography.

Aged↗

US-guided nephrostomy with the aid of a magnetic field-based navigation device in the porcine pelvicaliceal system.

PURPOSE: To assess the technique and feasibility of ultrasound (US)-guided nephrostomy performed with the aid of a magnetic field-based navigation device. MATERIALS AND METHODS: Twelve percutaneous nephrostomy procedures were performed in seven domestic pigs under real-time US guidance employing a navigation system. Two magnetic field sensors registered the actual position of the puncture needle and the US transducer. The actual needle position and the aimed puncture tract were graphically projected into the real-time US images, allowing exact navigation of the needle. After placement of the needle into the renal pelvis, the nephrostomy tube was inserted by means of the Seldinger technique. RESULTS: The puncture procedure was successfully performed in each case. The renal pelvis was punctured in a single attempt in 10 of 12 cases. In two cases, multiple attempts were necessary because bending of the puncture needle led to inaccuracies of the navigation system. With exception of two small perirenal urinomas, no complications were seen. CONCLUSIONS: The magnetic field-based navigation device allows easy and accurate performance of nephrostomy guided solely by US.

Animals↗

[Panorama ultrasonography of the abdominal wall for delineation of the anatomy and diagnosis of pathological findings].

PURPOSE: To assess extended field-of-view sonography for delineation of the anatomic structures of the abdominal wall and for the diagnosis of hernia. MATERIAL AND METHODS: In 34 cases (24 probands, 10 patients with abdominal wall defects) extended field-of-view sonography of the abdominal wall was performed with a 7.5 MHz transducer. Dynamic alignment of real-time images allows for depiction of regions of up to 60 cm in a single extended field-of-view image. A standardized axial image was obtained above and below the arcuate line and at the level of the defect, respectively. All images were evaluated by two blinded readers regarding the visibility of the anatomic structures and the delineation and extent of pathological changes. RESULTS: The abdominal wall was delineated with extended field-of-view sonography in all patients with a good image quality. The linea alba, the rectus muscle and the three lateral abdominal muscles, the rectus sheath, the peritoneum, and the subcutaneous fatty tissue were visible. In the patients with abdominal wall defects, the hernial sac with its contents, the extension of the defect, and the surrounding structures were clearly delineated. CONCLUSION: Extended field-of-view sonography allows for easily surveyed and reproducible documentation of the ultrasound examination of the abdominal wall. It is especially useful for the preoperative planning in patients with abdominal wall defects.

Abdominal Muscles↗

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation.

PURPOSE: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. MATERIALS AND METHODS: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 microm) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7 F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. RESULTS: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency intervention revealed no signs of residual tumor growth. CONCLUSION: The combined transcatheter embolization and percutaneous radiofrequency ablation of renal cell carcinoma has proved technically feasible, effective, and safe in this patient. It may be offered as an alternative treatment to partial or radical nephrectomy under certain circumstances.

Adult↗