Magnetic resonance elastography of the lung: technical feasibility.

Magnetic resonance elastography (MRE) is a phase-contrast technique that can spatially map shear stiffness within tissue-like materials. To date, however, MRE of the lung has been too technically challenging-primarily because of signal-to-noise ratio (SNR) limitations and phase instability. We describe an approach in which shear wave propagation is not encoded into the phase of the MR signal of a material, but rather from the signal arising from a polarized noble gas encapsulated within. To determine the feasibility of the approach, three experiments were performed. First, to establish whether shear wave propagation within lung parenchyma can be visualized with phase-contrast MR techniques, MRE was performed on excised porcine lungs inflated with room air. Second, a phantom consisting of open-cell foam filled with thermally polarized (3)He gas was imaged with MRE to determine whether shear wave propagation can be encoded by the gas. Third, preliminary evidence of the feasibility of MRE in vivo was obtained by using a longitudinal driver on the chest of a normal volunteer to generate shear waves in the lung. The results suggest that MRE in combination with hyperpolarized noble gases is potentially useful for noninvasively assessing the regional elastic properties of lung parenchyma, and merits further investigation.

Algorithms↗

Semi-automated digital image analysis of joint space width in knee radiographs.

OBJECTIVE: To design a semi-automated program to measure the minimum tibiofemoral joint space width (JSW) of knee radiographs. DESIGN: Bilateral knee radiographs were obtained twice within a 2 week period from 34 asymptomatic research participants. Radiographic images were analyzed to report both the variability of the image analysis program and the reproducibility of JSW measurements within a 2 week period. In addition, the results were compared with minimum JSW measurements read manually by an experienced musculoskeletal radiologist. RESULTS: The variability of the image analysis program was shown to be within one pixel. The results showed that reproducibility was better with the automated method. In addition, the manual method measured a greater minimum JSW than the automated method. There was no significant difference in between-day measurements. There was a significant difference reported between the automated and manual minimum JSW measurements. CONCLUSION: A novel semi-automated method for measurement of JSW has been developed.

Adult↗

Spatio-temporal directional filtering for improved inversion of MR elastography images.

Dynamic magnetic resonance elastography can visualize and measure propagating shear waves in tissue-like materials subjected to harmonic mechanical excitation. This allows the calculation of local values of material parameters such as shear modulus and attenuation. Various inversion algorithms to perform such calculations have been proposed, but they are sensitive to areas of low displacement amplitude (and hence low SNR) that result from interference patterns due to reflection and refraction. A spatio-temporal directional filter applied as a pre-processing step can separate interfering waves so they can be processed separately. Weighted combinations of inversions from such directionally separated data sets can significantly improve reconstructions of shear modulus and attenuation.

Algorithms↗

Magnetic resonance elastography of skeletal muscle.

While the contractile properties of skeletal muscle have been studied extensively, relatively little is known about the elastic properties of muscle in vivo. Magnetic resonance elastography (MRE) is a phase contrast-based method for observing shear waves propagating in a material to determine its stiffness. In this work, MRE is applied to skeletal muscle under load to quantify the change in stiffness with loading. A mathematical model of muscle is developed that predicts a linear relationship between shear stiffness and muscle load. The MRE technique was applied to bovine muscle specimens (N = 10) and human biceps brachii in vivo (N = 5). Muscle stiffness increased linearly for both passive tension (14.5 +/- 1.77 kPa/kg) and active tension, in which the increase in stiffness was dependent upon muscle size, as predicted by the model. A means of noninvasively assessing the viscoelastic pro-perties of skeletal muscle in vivo may provide a useful method for studying muscle biomechanics in health and disease.

Animals↗

Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation.

Noninvasive quantitation of the mechanical properties of tissue could improve early detection of pathology. Previously a method for detecting displacement from propagating shear waves using a phase-contrast MRI technique was developed. In this work it is demonstrated how a collection of data representing the full vector displacement field could be used to potentially estimate the full complex stiffness tensor. An algebraic inversion approach useful for piece-wise homogeneous materials is described in detail for the general isotropic case, which is then specialized to incompressible materials as a model for tissue. Results of the inversion approach are presented for simulated and experimental phantom data that show the technique can be used to obtain shear wave-speed and attenuation in regions where there is sufficient signal-to-noise ratio in the displacement and its second spatial derivatives. The sensitivity to noise is higher in the attenuation estimates than the shear wave-speed estimates. Magn Reson Med 45:299-310, 2001.

Computer Simulation↗

FLAIR histogram segmentation for measurement of leukoaraiosis volume.

The purposes of this study were to develop a method to measure brain and white matter hyperintensity (leukoaraiosis) volume that is based on the segmentation of the intensity histogram of fluid-attenuated inversion recovery (FLAIR) images and to assess the accuracy and reproducibility of the method. Whole-head synthetic image phantoms with manually introduced leukoaraiosis lesions of varying severity were constructed. These synthetic image phantom sets incorporated image contrast and anatomic features that mimicked leukoaraiosis found in real life. One set of synthetic image phantoms was used to develop the segmentation algorithm (FLAIR-histoseg). A second set was used to measure its accuracy. Test retest reproducibility was assessed in 10 elderly volunteers who were imaged twice. The mean absolute error of the FLAIR-histoseg method was 6.6% for measurement of leukoaraiosis volume and 1.4% for brain volume. The mean test retest coefficient of variation was 1.4% for leukoaraiosis volume and 0.3% for brain volume. We conclude that the FLAIR-histoseg method is an accurate and reproducible method for measuring leukoaraiosis and whole-brain volume in elderly subjects.

Aged↗

Magnetic resonance elastography: non-invasive mapping of tissue elasticity.

Magnetic resonance elastography (MRE) is a phase-contrast-based MRI imaging technique that can directly visualize and quantitatively measure propagating acoustic strain waves in tissue-like materials subjected to harmonic mechanical excitation. The data acquired allows the calculation of local quantitative values of shear modulus and the generation of images that depict tissue elasticity or stiffness. This is significant because palpation, a physical examination that assesses the stiffness of tissue, can be an effective method of detecting tumors, but is restricted to parts of the body that are accessible to the physician's hand. MRE shows promise as a potential technique for 'palpation by imaging', with possible applications in tumor detection (particularly in breast, liver, kidney and prostate), characterization of disease, and assessment of rehabilitation (particularly in muscle). We describe MRE in the context of other recent techniques for imaging elasticity, discuss the processing algorithms for elasticity reconstruction and the issues and assumptions they involve, and present recent ex vivo and in vivo results.

Acoustics↗

Autocorrection of three-dimensional time-of-flight MR angiography of the Circle of Willis.

OBJECTIVE: The purpose of this study was to investigate the efficacy of a retrospective adaptive motion correction technique known as autocorrection for reducing motion-induced artifacts in high-resolution three-dimensional time-of-flight MR angiography of the circle of Willis. MATERIALS AND METHODS: Ten consecutive volunteers were imaged with an unenhanced gradient-recalled echo three-dimensional time-of-flight MR angiography sequence of the circle of Willis. Each volunteer was asked to rotate approximately 2 degrees after completion of one third and one half of the acquisition in the axial, sagittal, and oblique planes (45 degrees to the axial and sagittal planes). A single static data set was also acquired for each volunteer. Unprocessed and autocorrected maximum-intensity-projection images were reviewed as blinded image pairs by six radiologists and were compared on a five-point image quality scale. RESULTS: Mean improvement in image quality after autocorrection was 1.4 (p < 0.0001), 1.1 (p < 0.0001), and 0.2 (p = 0.003) observer points (maximum value, 2.0), respectively, for examinations corrupted by motion in the axial, oblique, and sagittal planes. All three axes had statistically significant improvement in image quality compared with the uncorrected images. Changes in image quality after the application of the autocorrection algorithm to static angiogram data were not statistically significant (mean change in score = -0.13 points; p = 0.29). CONCLUSION: Autocorrection can reduce artifacts in motion-corrupted MR angiography of the circle of Willis without distorting motion-free examinations.

Artifacts↗

Image metric-based correction (autocorrection) of motion effects: analysis of image metrics.

Magnetic resonance (MR) imaging of the shoulder necessitates high spatial and contrast resolution resulting in long acquisition times, predisposing these images to degradation due to motion. Autocorrection is a new motion correction algorithm that attempts to deduce motion during imaging by calculating a metric that reflects image quality and searching for motion values that optimize this metric. The purpose of this work is to report on the evaluation of 24 metrics for use in autocorrection of MR images of the rotator cuff. Raw data from 164 clinical coronal rotator cuff exams acquired with interleaved navigator echoes were used. Four observers then scored the original and corrected images based on the presence of any motion-induced artifacts. Changes in metric values before and after navigator-based adaptive motion correction were correlated with changes in observer score using a least-squares linear regression model. Based on this analysis, the metric that exhibited the strongest relationship with observer ratings of MR shoulder images was the entropy of the one-dimensional gradient along the phase-encoding direction. We speculate (and show preliminary evidence) that this metric will be useful not only for autocorrection of shoulder MR images but also for autocorrection of other MR exams.

Algorithms↗

Rapid autocorrection using prescan navigator echoes.

Autocorrection is an adaptive motion correction algorithm that does not require an in vivo measurement of the motion record. A novel method for ensuring convergence of this algorithm when motion is severe is presented. A limited number of navigator echoes are acquired before the imaging sequence to obtain a "snapshot" of the object. Phase differences between the navigator and image k-space data are used as an estimate of motion-induced phase shifts in the image, followed by autocorrection. In phantom data a six-fold reduction in computation time compared to autocorrection alone was realized. These results indicate that this navigator/autocorrection combination may be useful for reducing motion artifacts and computation time for MR exams when motion along the image phase encoding axis is severe.

Algorithms↗

An investigation of the effects of mammographic acquisition parameters on a semiautomated quantitative measure of breast cancer risk.

The aim of this work was to investigate the effect of mammographic acquisition parameter variations on the estimation of percent density (PD) produced by a particular semiautomated algorithm. The PD algorithm requires the user to specify a threshold pixel value segmenting breast tissue of greater and lesser density. A whole breast specimen was imaged using a variety of acquisition techniques, and the image data were processed as prescribed by the PD algorithm. PD estimates for all possible values of the user threshold were calculated for all the images. The image data were normalized so that PD varied between 30% and 80% over a fixed threshold range of 23, and a PD value of 50% was obtained for a threshold value of 195. PD differences between all the images and a baseline standard mammographic acquisition technique were calculated. We also estimated PD differences caused by small (3%) variations in operator selection of the threshold value. We found that the largest differences in PD involved changes in the density control of the mammography unit, and changes in the detector (either film type or computed radiography). The maximum PD differences due to technique were all less than 10%, with root-mean-square (RMS) variations less than 4%. PD differences due to operator variation were 24% (maximum) and 6.1% (RMS). These findings suggest that PD differences due to mammographic technique will be considerably less than those inherent to the technique, due to operator variation. All of these estimates are likely larger than differences seen in practice since optimization of the threshold by the operator was not considered in this analysis.

Algorithms↗

Ultrasound grayscale image compression with JPEG and wavelet techniques.

The purpose of the study was to evaluate the effects of lossy compression on grayscale ultrasound images to determine how much compression can be applied while still maintaining images that are acceptable for diagnostic purposes. The study considered how the acquisition technique (video frame-grabber versus directly acquired in digital form) influences how much compression can be applied. For directly acquired digital images, the study considered how text (that is burned into the image) affects the compressibility of the image. The lossy compression techniques that were considered include JPEG and a Wavelet algorithm using set partitioning in hierarchical trees (SPIHT).

Image Processing, Computer-Assisted↗

Tissue characterization using magnetic resonance elastography: preliminary results.

The well-documented effectiveness of palpation as a diagnostic technique for detecting cancer and other diseases has provided motivation for developing imaging techniques for noninvasively evaluating the mechanical properties of tissue. A recently described approach for elasticity imaging, using propagating acoustic shear waves and phase-contrast MRI, has been called magnetic resonance elastography (MRE). The purpose of this work was to conduct preliminary studies to define methods for using MRE as a tool for addressing the paucity of quantitative tissue mechanical property data in the literature. Fresh animal liver and kidney tissue specimens were evaluated with MRE at multiple shear wave frequencies. The influence of specimen temperature and orientation on measurements of stiffness was studied in skeletal muscle. The results demonstrated that all of the materials tested (liver, kidney, muscle and tissue-simulating gel) exhibit systematic dependence of shear stiffness on shear rate. These data are consistent with a viscoelastic model of tissue mechanical properties, allowing calculation of two independent tissue properties from multiple-frequency MRE data: shear modulus and shear viscosity. The shear stiffness of tissue can be substantially affected by specimen temperature. The results also demonstrated evidence of shear anisotropy in skeletal muscle but not liver tissue. The measured shear stiffness in skeletal muscle was found to depend on both the direction of propagation and polarization of the shear waves.

Animals↗

Autocorrection in MR imaging: adaptive motion correction without navigator echoes.

A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those achieved with navigator echoes. The results demonstrate that autocorrection can significantly reduce motion artifacts in a technically demanding MR imaging application.

Algorithms↗

A prospective approach to correct for inter-image head rotation in fMRI.

Global head motion occurring between successive image acquisitions during a functional MRI time series can corrupt the signal of physiologic brain activation, potentially invalidating interpretation of the final activation map from that particular fMRI time series. By approximating the head as a rigid body, multiaxial global head motion can be decomposed into orthogonal linear and rotational components. This paper describes a method using orbital navigator echoes to provide prospective correction for both through-plane and in-plane inter-image head rotation in functional MRI. The dynamic detection and correction of rotation can be performed in <100 ms. Phantom experiments demonstrate accurate correction of rotational motion over a range of +/-0.36 degrees to +/-12 degrees. Imaging studies in volunteers document the feasibility of real-time prospective correction of rotational motion in vivo. Using a modified receiver operating characteristic method, motion-corrected functional MRI sensorimotor studies incorporating deliberate head rotations are shown to be superior to functional MRI time series acquired under similar conditions but without motion correction.

Artifacts↗

Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction.

Grayscale inhomogeneities in magnetic resonance (MR) images confound quantitative analysis of these images. Homomorphic unsharp masking and its variations have been commonly used as a post-processing method to remove inhomogeneities in MR images. However, little data is available in the literature assessing the relative effectiveness of these algorithms to remove inhomogeneities, or describing how these algorithms can affect image data. In this study, we address these questions quantitatively using simulated images with artificially constructed and empirically measured bias fields. Our results show that mean-based filtering is consistently more effective than median-based algorithms for removing inhomogeneities in MR images, and that artifacts are frequently introduced into images at the most commonly used window sizes. Our results demonstrate dramatic improvement in the effectiveness of the algorithms with significantly larger windows than are commonly used.

Algorithms↗

Detection of subtle abnormalities on chest radiographs after irreversible compression.

PURPOSE: To assess the effect of wavelet-based compression of posteroanterior chest radiographs on detection of small uncalcified pulmonary nodules and fibrosis. MATERIALS AND METHODS: Computed tomography (CT) of the chest was used to identify 20 patients with normal posteroanterior chest radiographs, 20 with a solitary uncalcified pulmonary nodule 1-2 cm in diameter, and 20 with fibrotic disease. A double-blind protocol for readings of original images and images compressed at 40:1 and 80:1 was analyzed by using the nonparametric receiver operating characteristic to measure differences in diagnostic accuracy and their statistical significance. RESULTS: There was no substantial difference in the overall diagnostic accuracy (measured by the area under the curve index) for both nodules and fibrosis between images compressed at 40:1 and 80:1 and uncompressed images. Readers tended to perform better on images compressed at 40:1 compared with uncompressed images. The "high-sensitivity" portion of the 80:1 compression curve for nodules was below that for the uncompressed curve, although this was not statistically significant. CONCLUSION: Lossy compression of chest radiographs at 40:1 can be used without decreased diagnostic accuracy for detection of pulmonary nodules and fibrosis. There is no statistically significant difference in diagnostic accuracy at 80:1 compression, but detection ability is decreased.

Algorithms↗