PubMed HealthSearch

Biomedical subjects

A Mazzucco

Publications and source records attributed to A Mazzucco.

At least 19 recordsLinked to original sources

A new, noninvasive method to monitor the aging of bioprosthetic valves in the mitral position.

Bioprosthetic valves undergo a tissue degeneration of unpredictable onset and amount. This process alters the structure and function of the valve and consequently shortens its lifespan. The echocardiographic technique usually used in the follow-up of these patients does not provide accurate information concerning the amount of prosthesis tissue degeneration. A new technique has been developed based on the spectral analysis of the first heart sound, which enables the evaluation of prosthetic leaflet stiffness. The Young's modulus (E) and stress (s) of the valve leaflets were derived as functions of the inner diameter of the heterograft and its primary vibration frequency, which can be obtained from the frequency spectrum of the first heart sound. Thirty-six patients with a mitral bioprosthetic valve were studied. Fifteen had thickening or calcification, or both, of the valvular leaflets at echocardiographic examination. In patients with a normal valve, E and s showed a good correlation with the duration of implantation (r = 0.909, p < 0.001; and r = 0.828, p < 0.001; respectively). Patients with abnormal leaflets had values of E and s that were greater than the theoretical values expected for their duration of implantation. The procedure is sensitive, accurate and easy to perform, and enables monitoring of the aging of the prosthetic valve and early identification of valve tissue degeneration. Together with echocardiography, this procedure yields a more complete evaluation of prosthetic valves for the follow-up of patients.

Aged

The Meadox-Gabbay pericardial xenograft: failure of the unicusp principle.

Durability of a new bioprosthesis, the Meadox-Gabbay unileaflet pericardial xenograft, was evaluated by reviewing a series of 12 patients who received this device in the mitral position from 1983 to 1985. Bioprosthetic failure necessitated reoperation in 5 patients 21, 22, 53, 66, and 81 months after placement. Three patients died of cardiac failure after 31, 52, and 70 months; no postmortem examinations were done. In 2 of the 3 patients, an echocardiographic study had shown signs of valvular dysfunction. Pathological examination of five available explants revealed the presence of redundancy and stretching of the single pericardial leaflet in all of them; in one, this lesion alone caused severe prosthetic incompetence. Other pathological findings included cusp and commissural calcification and commissural tears with or without calcification. Histologic examination and electron microscopy showed intrinsic calcification involving both collagen bundles and cellular debris and various degrees of collagen disruption. In this limited series of patients, the Meadox-Gabbay pericardial xenograft demonstrated various modes of failure that markedly impair its durability and render it unsuitable as a cardiac valve substitute.

Adult

Annular enlargement during aortic valve replacement: preliminary results with a simplified technique.

A simplified technique has been used to enlarge the aortic annulus in a series of 13 patients undergoing aortic valve replacement. The procedure basically consists of extending the aortotomy incision into the aortic annulus by dividing the commissure between the left and noncoronary sinuses, without involving the anterior mitral leaflet. Wide opening of the commissure is obtained and the resulting defect is closed, preferably using a patch of bovine pericardium sutured to the mitral annulus and aortic wall. This technique is simple, reproducible, avoids opening of the left atrium (reducing the potential bleeding sites), allows insertion of a prosthesis at least two sizes larger than the original annulus, and is also applicable in cases of mitral-aortic valve replacement. Our preliminary results are satisfactory and seem to demonstrate that in many patients, even in the young age group, more complex procedures are often unnecessary when enlargement of the aortic annulus is required.

Adult

Contractile properties and Ca2+ release activity of the sarcoplasmic reticulum in dilated cardiomyopathy.

BACKGROUND: We performed a comparative study on Ca2+ release activity of the sarcoplasmic reticulum and calcium sensitivity of contractile apparatus of chemically skinned myocardial fibers obtained from four nonfailing human hearts and 13 excised hearts from patients with idiopathic dilated cardiomyopathy. METHODS AND RESULTS: Ca2+ sensitivity of contractile apparatus was studied by following the isometric tension developed by chemically skinned myocardial fibers challenged with solutions of decreasing pCa. Ca2+ release from sarcoplasmic reticulum was monitored indirectly by measurement of the isometric tension developed by skinned fibers challenged with caffeine. We observed no significant difference of Ca2+ sensitivity and cooperativity between normal myocardium (pCa50 = 6.00 +/- 0.05; Hill coefficient, nHill = 2.07 +/- 0.10) and dilated cardiomyopathy (pCa50 = 6.03 +/- 0.07; nHill = 2.72 +/- 0.30) when the fibers were stretched to 130% of the resting length. We also found that both in normal myocardium and dilated cardiomyopathy, stretching to 150% of the resting length increased the Ca2+ sensitivity of the contractile system; pCa50 = 6.21 +/- 0.01 and 6.13 +/- 0.04 in normal and dilated cardiomyopathy, respectively, whereas in dilated cardiomyopathy there was a decrease of Hill coefficient with stretching that was not observed in the control group. The caffeine threshold in idiopathic dilated cardiomyopathy was markedly increased compared with the control group, 1.94 +/- 0.27 mmol/l and 0.29 +/- 0.04 mmol/l caffeine, respectively, whereas there were no significant differences in the extent and rate of caffeine-induced Ca2+ release. CONCLUSIONS: These results indicate that in idiopathic dilated cardiomyopathy there is no alteration of contractile and regulatory proteins; on the contrary, the gating mechanism of the Ca2+ release channel of sarcoplasmic reticulum is abnormal, suggesting a possible involvement of the excitation-contraction coupling in the pathogenesis of this disease. It should also be taken into account, however, that the increased caffeine threshold in dilated cardiomyopathy would be a result of the enhanced resistance to the skinning procedure secondary to the modification of lipid species and/or content in sarcoplasmic reticulum membrane.

Adolescent

Original expectations of the Hancock valve and 20 years of clinical reality.

The standard (glutaraldehyde-preserved) Hancock porcine bioprosthesis was introduced into clinical practice in order to provide surgeons with a cardiac valve substitute which would be nonthrombogenic and therefore would not require anticoagulation, and would be durable, anatomically suitable, and noiseless. In the present report we have reviewed our long-term experience with Hancock porcine valve recipients in order to verify the original expectations of this bioprosthesis have been met.

Adolescent

Does Down syndrome affect prognosis of surgically managed atrioventricular canal defects?

The appropriateness of surgical correction of complete atrioventricular canal defect in patients with Down syndrome has been questioned on a cost-benefit basis. Our experience with nonselective correction of all patients with atrioventricular canal defects gave us the opportunity to evaluate the impact of Down syndrome on postoperative survival. Between January 1, 1975, and December 31, 1989, we operated on 94 patients with Down syndrome and on 127 genetically normal patients. One hundred thirty-four patients had partial or intermediate atrioventricular canal defect (28% Down patients) and 87 had complete atrioventricular canal defect (74% Down patients). Thirty-two patients died perioperatively and 10 patients died during the 15-year follow-up. The actuarial survival was 90% in the genetically normal patients and 57% in patients with Down syndrome (p < 0.0001). Nonetheless, when the confounding effects of pulmonary vascular resistance and the prevalence of more severe anatomic forms in patients with Down syndrome were eliminated with a multivariable analysis in the hazard domain, Down syndrome was not a significant independent incremental risk factor. This was verified by fitting parametric survival to actuarial survival graphically and by a testing of fit. Patients with Down syndrome underwent fewer reoperations and fared as well as or even better, on clinical and echocardiographic investigation, than their genetically normal counterparts.

Adolescent

Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.

Actuarial Analysis

Failure of Hancock pericardial xenografts: is prophylactic bioprosthetic replacement justified?

The incidence of major valve-related complications was evaluated in a series of patients in whom the Hancock pericardial xenograft was used for aortic (AVR; n = 84), mitral (MVR; n = 17) and mitral-aortic (MAVR; n = 13) valve replacement. At 7 years actuarial survival is 66% +/- 8% after AVR, 64% +/- 13% after MVR, and 41% +/- 15% after MAVR, whereas actuarial freedom from valve-related death is 79% +/- 7% after AVR, 78% +/- 13% after MVR, and 81% +/- 12% after MAVR. Actuarial freedom from thromboemboli and anticoagulant-related hemorrhage at 7 years is 93% +/- 4% and 98% +/- 2% after AVR and 83% +/- 10% and 88% +/- 11% after MVR; no such complications occurred after MAVR. Structural valve deterioration determined at reoperation, at autopsy, or by clinical investigation was observed in 34 patients with AVR (10.0 +/- 0.2%/patient-year), in 10 with MVR (10.6 +/- 3.3%/patient-year), and in 9 with MAVR (16.6 +/- 5.5%/patient-year). After AVR, 19 patients underwent reoperation and 2 died before reoperation; 4 patients with MVR underwent reoperation, and 7 patients with MAVR underwent reoperation and 1 died before reoperation. Seventy-eight percent of the current survivors (13 patients with AVR, 7 with MVR, and 1 with MAVR) have clinical evidence of valve failure. At 7 years actuarial freedom from structural deterioration of the Hancock pericardial xenograft is 25% +/- 7% after AVR, 29% +/- 14% after MVR, and 0% after MAVR.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Influence of type of prosthesis on late results after combined mitral-aortic valve replacement.

The influence of type of prosthesis on the late outcome of patients with combined mitral-aortic valve replacement was analyzed by comparing, at a 14-year follow-up, patients receiving two biological prostheses (group 1; n = 135), two mechanical prostheses (group 2; n = 221), or a mechanical prosthesis in the aortic position and a bioprosthesis in the mitral position (group 3; n = 97). No difference was found among the three groups in terms of actuarial survival and incidence of and freedom from valve-related deaths, thromboemboli, and hemorrhages. Patients with biological prostheses had a significantly greater incidence of structural valve deterioration, reoperations, and overall complications when compared with patients with only mechanical prostheses. The results of an extended follow-up of patients with combined mitral-aortic valve replacement indicate that mechanical prostheses perform better in the long-term owing to their superior durability when compared with biological valves. The use of bioprostheses should be confined to old patients with limited life expectancy because of their cardiac disease, provided that anticoagulants are not used. Combination of mechanical and biological prostheses in the same patient should be avoided because the advantages of each type of prosthesis are lost.

Adult

Electrical instability in patients undergoing surgery for atrioventricular septal defect.

Postoperative 24-hour Holter monitoring was performed in 106 patients with atrioventricular septal defect in order to identify the incidence of atrial and ventricular arrhythmias. Of the patients, 72 had separate atrioventricular orifices, including 13 with a small ventricular component to the defect, and 34 patients had a common atrioventricular orifice. Two groups of abnormal patients were found. First, patients with good electrical stability characterized by isolated atrial (9 patients) and ventricular (25 patients) extrasystoles falling in classes I and II of Lown. Second, patients with marked electrical instability characterized in one patient by repetitive atrial extrasystoles, in another by atrial flutter, in 2 by polymorphic ventricular extrasystole and in 8 by couplets or triplets. Electrical instability in individual patients was then compared, by means of logistic regression analysis, with operative, surgical and postoperative variables. There was no incidence of sudden death in our series. After surgical repair, ventricular arrhythmias were more frequent than atrial arrhythmias (33% vs. 10%) and were unrelated to the type of atrioventricular septal defect. Cardiac electrical instability after operation was significantly related to larger operative body size, higher postoperative end diastolic diameter of the right ventricle, larger size of the ventricular septal defect, coexistence of postoperative right bundle branch block and left anterior hemiblock. Conversely, the risk of arrhythmias was reduced by more recent operative data and by greater shortening fraction of the left ventricle.

Arrhythmias, Cardiac

Value and limitations of transesophageal echocardiographic monitoring during percutaneous balloon mitral valvotomy.

To determine the utility of transesophageal echocardiographic monitoring during percutaneous balloon mitral valvotomy, we analyzed data from 40 consecutive patients who had been randomly assigned to undergo balloon mitral valvotomy under transesophageal echocardiographic guidance or without echo. All procedures were carried out under general anaesthesia. The completion rate (100% vs 73%), the procedure time (108 +/- 28 min vs 65 +/- 18 min), the X-ray exposure time (62 +/- 13 vs 33 +/- 12 min), resulted significantly (P less than 0.001) more favorable in the echo-monitored patients. Moreover, a lower rate of major complications (cardiac tamponade, large residual atrial shunting, and severe mitral regurgitation) was noted in the echo-monitored patients. The achieved final area of the mitral valve did not differ significantly between the two groups. From an evaluation of results as a whole, 96% of the echo-monitored procedures were successful, whereas only 40% of the procedures conducted without echocardiographic control achieved a satisfactory final result in absence of major complications. We conclude that transesophageal echocardiography is a safe, effective, and valuable tool to monitor each step of balloon mitral valvotomy in order to shorten the time of the procedure, and to improve the results of this complex interventional catheterization technique.

Adult

Is lung biopsy useful for surgical decision making in congenital heart disease?

Sixty patients with congenital heart disease (CHD), age range 3 months-45 years (median 2 years), underwent lung biopsy to exclude pulmonary vascular disease (PVD): 25 had an atrioventricular (AV) septal defect, 14 a ventricular septal defect (VSD), 7 a complete transposition of the great arteries (TGA) + VSD, 3 an atrial septal defect, and 2 a patent ductus arteriosus; 9 had other malformations. Scoring of histological section (0-4) according to a modified Heath-Edwards classification disclosed that 30 patients had severe "irreversible" PVD (greater than or equal to grade 3) (11 AV septal defect, 8 VSD, 6 TGA + VSD and 5 others); 8 patients were younger than 1 year. Pulmonary vascular resistance (PVR) was calculated in 51 patients and exceeded 7 U/m2 in 1 of 2 patients with grade 0, in 9 of 18 with grade 1, in 1 of 4 with grade 2, in 11 of 18 with grade 3, and in 8 of 9 with grade 4. PVR was also calculated after 100% oxygen administration in 19 patients, 14 of whom had a resting PVR greater than or equal to 7 U/m2. PVR persisted greater than or equal to 7 U/m2 in 5 patients: 4 had PVD greater than or equal to grade 3 and died after surgery. PVR fell to under 7 U/m2 in 14 patients, 3 of whom had PVD greater than or equal to grade 3:1 patient with grade 4 was not operated upon and 2 with grade 3 were operated upon: all are alive. Follow-up in discharged living patients was 100%, with a mean of 50 months. Fifty-five patients underwent surgery with 10 early and 2 late deaths. Among the 12 subjects with a fatal outcome, 10 had irreversible lesions. The 5 non-operated patients all had irreversible lesions at biopsy, and are still alive.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Extended follow-up of the standard Hancock porcine bioprosthesis.

We have reviewed 665 patients in whom the standard Hancock porcine bioprosthesis (HPB) was used for aortic (AVR = 173), mitral (MVR = 437), and mitral and aortic (MAVR = 55) valve replacement in the time interval from 1970 to 1983. After AVR, HPB-related deaths occurred in 24 patients (1.7% +/- 0.4% per patient-year); 11 had thromboembolic episodes (0.8% +/- 0.2% per patient-year), 6 hemorrhages related to anticoagulants (0.4% +/- 0.2% per patient-year), 9 endocarditis (0.7% +/- 0.2% per patient-year), 7 prosthetic leak (0.5% +/- 0.1% per patient-year), and 59 structural deterioration (4.3% +/- 0.6% per patient-year). At 16 years, actuarial survival is 40% +/- 6%, freedom from thromboembolic episodes 89% +/- 4%, from hemorrhages 90% +/- 5%, from endocarditis 94% +/- 2%, from prosthetic leak 95% +/- 2%, and from structural deterioration 36% +/- 6%. After MVR, HPB-related deaths occurred in 64 patients (1.6% +/- 0.2% per patient-year); 68 had thromboembolic episodes (1.7% +/- 0.2% per patient-year), 28 hemorrhages (0.7% +/- 0.1% per patient-year), 12 endocarditis (0.3% +/- 0.1% per patient-year), 9 prosthetic leak (0.2% +/- 0.1% per patient-year), and 158 structural deterioration (4.0% +/- 0.3% per patient-year). At 18 years, actuarial survival is 33% +/- 4%, freedom from thromboembolic episodes 57% +/- 13%, from hemorrhages 81% +/- 6%, from endocarditis 91% +/- 4%, from prosthetic leak 98% +/- 1%, and from structural deterioration 18% +/- 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis

The risk of reoperation in patients with bioprosthetic valves.

The risk of operative mortality in patients undergoing a first reoperation for bioprosthetic failure was assessed in a series of patients reoperated upon during the last two decades (1970-1990). A total of 330 such patients underwent replacement of 351 bioprostheses: 88 had aortic; 221 mitral; and 21 mitral and aortic bioprosthetic replacement. Indication for reoperation was in most cases structural valve deterioration (87%), followed by periprosthetic leak (7%) and endocarditis (6%). The operative mortality was significantly higher in patients who preoperatively were in New York Heart Association Functional Class IV or had a lower left ventricular function, in those reoperated because of prosthetic infection, and in those reoperated on an emergency basis. Structural valve deterioration was associated to a substantially low risk; operative mortality has improved in recent years, regardless of the indication for reoperation, partly due to the increasing experience and improved surgical techniques. Our results indicate that in recipients of bioprosthetic valves, careful follow-up with closer surveillance of valve and cardiac function and earlier prosthetic replacement might contribute to reducing the risk of reoperation.

Adolescent

[Follow-up using echocardiography and ambulatory electrocardiography of patients after excision of intracardiac myxoma].

From November 1968 to May 1990, 56 patients, 19 male and 37 female (mean age 49 +/- 14 years) underwent excision of an intracardiac myxoma (M). M was located into the left atrium in 48 (86%), the right atrium in 6 (11%), and the right ventricle in 2 (3.5%). Operation consisted of excision of the tumor together with its base of attachment. There were 2 early (3.5%) and 2 late (3.7%) deaths. Actuarial survival at 20 years is 91 +/- 4%. Non-invasive reevaluation has been carried out in 44 patients (84%), 39 with left atrial M, 4 with right atrial M, and 1 with right ventricular M. 2-D echocardiography ruled out tumor recurrence in all patients and showed, in those with left atrial M, a reduction in the size of the atrial chamber; on the contrary, left ventricular systolic diameter, diastolic diameter and ejection fraction were unmodified. In 7 patients (15.9%) a residual mild mitral insufficiency was disclosed. In 34 patients 24-hour electrocardiographic monitoring reevaluation showed a low incidence of major supraventricular arrhythmias, late postoperatively (short runs of paroxysmal supraventricular tachycardia in 3 patients, and atrial ectopic rhythm in 1). All these patients had undergone tumor excision by biatrial approach. Based on our results, we conclude that excision of intracardiac myxomas is curative and long-term survival is excellent. Non-invasive reevaluation of patients by 2-D echocardiography and 24-hour electrocardiographic monitoring is mandatory in order to promptly disclose possible complications, particularly tumor recurrence and arrhythmias.

Adolescent