PubMed Health⌕ Search

Biomedical subjects

A Merkoçi

Publications and source records attributed to A Merkoçi.

6 recordsLinked to original sources

Electrochemical genosensors for biomedical applications based on gold nanoparticles.

Two gold nanoparticles-based genomagnetic sensors designs for detection of DNA hybridization are described. Both assays are based on a magnetically induced direct electrochemical detection of gold tags on magnetic graphite-epoxy composite electrodes. The first design is a two strands assay format that consists of the hybridization between a capture DNA strand which is linked with paramagnetic beads and another DNA strand related to BRCA1 breast cancer gene used as a target which is coupled with streptavidin-gold nanoparticles. The second genomagnetic sensor design is a sandwich assay format with more application possibilities. A cystic fibrosis related DNA strand is used as a target and sandwiched between two complementary DNA probes: the first one linked with paramagnetic beads and a second one modified with gold nanoparticles via biotin-streptavidin complexation reactions. The electrochemical detection of gold nanoparticles by differential pulse voltammetry was performed in both cases. The developed genomagnetic sensors provide a reliable discrimination against noncomplementary DNA as well against one and three-base mismatches. Optimization parameters affecting the hybridization and analytical performance of the developed genosensors are shown for genomagnetic assays of DNA sequences related with the breast cancer and cystic fibrosis genes.

Biosensing Techniques↗

Sensitive stripping voltammetry of heavy metals by using a composite sensor based on a built-in bismuth precursor.

A new graphite-epoxy composite electrode (GECE) containing Bi(NO(3))(3) as a built-in bismuth precursor for simultaneous and individual anodic stripping analysis of heavy trace metals like lead and cadmium is reported. The developed Bi(NO(3))(3)-GECE is compatible with bismuth film electrodes reported previously including the composite electrodes (Bi-GECE) recently reported by our group. Bi(NO(3))(3)-GECE displays the ability for the detection of both individual and simultaneous determination of heavy trace metals and exhibits well defined, reproducible and sharp stripping signals. The sensitive response is combined with the minimal toxicity of Bi(NO(3))(3). This novel sensor would be an appropriate alternative tool to sensors using bismuth in solution during their utilization in environmental quality monitoring as well as other applications.

Bismuth↗

Rapid electrochemical genosensor assay using a streptavidin carbon-polymer biocomposite electrode.

A sensor capable of detecting a specific DNA sequence was designed by bulk modification of a graphite epoxy composite electrode with streptavidin (2% w/w). Streptavidin is used to immobilise a biotinylated capture DNA probe to the surface of the electrode. Simultaneous hybridisation occurs between the biotin DNA capture probe and the target-DNA and between the target-DNA and a digoxigenin modified probe. The rapid binding kinetic of streptavidin-biotin allows a one step immobilisation/hybridisation procedure. Secondly, enzyme labelling of the DNA duplex occurs via an antigen-antibody reaction between the Dig-dsDNA and an anti-Dig-HRP. Finally, electrochemical detection is achieved through a suitable substrate (H2O2) for the enzyme-labelled duplex. Optimisation of the sensor design, the modifier content and the immobilisation and hybridisation times was attained using a simple nucleotide sequence. Regeneration of the surface is achieved with a simple polishing procedure that shows good reproducibility. The generic use of a modified streptavidin carbon-polymer biocomposite electrode capable of surface regeneration and a one step hybridisation/immobilisation procedure are the main advantages of this approach. In DNA analysis, this procedure, if combined with the polymerase chain reaction, would represent certain advantages with respect to classical techniques, which prove to be time consuming in situations where a simple and rapid detection is required. This innovative developed material may be used for the detection of any analyte that can be coupled to the biotin-streptavidin reaction, as is the case of immunoassays.

Biosensing Techniques↗

Classical dot-blot format implemented as an amperometric hybridisation genosensor.

A new electrochemical hybridisation genosensor has been designed. This genosensor is based on a concept adapted from classical dot-blot DNA analysis, but implemented in an electrochemical biosensor configuration. The use of amperometric transduction and the enzyme label method--that increases the genosensor sensitivity--are the main features of this new approach. The analytical procedure consists of five steps: DNA target immobilisation by adsorption onto a nylon membrane, hybridisation between DNA target and biotin-DNA probe, complexation reaction between biotin-DNA probe and an enzyme (horseradish peroxidase) streptavidin conjugate; integration of the modified membrane onto an electrochemical transducer; and finally, amperometric detection using a suitable substrate for the enzyme labelled duplex. Besides the adapted dot-blot format, a competitive assay in which the target is in solution is reported as well. This procedure, based on amperometric transduction, represents certain advantages with respect to dot-blot analysis: labelled hybrid detection is far simpler, quicker and requires more ordinary or simple reactives; the response obtained is a direct analytical signal via low-cost instrumentation, a nonisotopic labelling is used, and the membranes can be reused. These characteristics are ideal in implementing the procedure developed in kit form.

Adsorption↗

Dot-blot amperometric genosensor for detecting a novel determinant of beta-lactamase resistance in Staphylococcus aureus.

A new electrochemical hybridisation genosensor for the detection of resistant bacteria has been developed. This device relies on the immobilisation of a 50-mer oligonucleotide target, unique to a novel determinant of beta-lactamase resistance in Staphylococcus aureus, onto an electrochemical transducer. This genosensor is based on a concept adapted from classical dot-blot DNA analysis, but implemented in an electrochemical biosensor configuration. Amperometric transduction and an enzyme label method, that increases the genosensor sensitivity, are the main features of this new approach. In addition to the adapted dot-blot format, a double hybridisation assay, in which two different labelled probes were used, is reported. This procedure, if combined with polymerase chain reaction (PCR), allows determination of the genotype of an antibiotic-resistant organism in a shorter time than that required to perform traditional phenotypic susceptibility testing. Its characteristics are ideal for implementation in a kit form.

Biosensing Techniques↗

Electrochemical genosensor design: immobilisation of oligonucleotides onto transducer surfaces and detection methods.

The present report reviews immobilisation techniques of purified oligonucleotides on electrochemical transducers and their corresponding detection techniques. Most of the literature reviewed was published in the 1990s. The immobilisation techniques of a DNA probe to the surface of an electrochemical transducer made from carbon, gold, platinum or polypyrrole, ranged from simple adsorption to covalent bonding. Recent efforts to couple the recognition layer containing the immobilised nucleic acid recognition layer with the electrochemical signal transducer are discussed. Special attention is given to hybridisation biosensing based on electroactive indicators.

Adsorption↗