Measured and modelled concentrations and vertical profiles of airborne particulate matter within the boundary layer of a street canyon.

Concentrations and vertical profiles of various fractions of airborne particulate matter (suspended particulate matter (SPM), PM10 and PM2.5) have been measured over the first three metres from ground in a street canyon. Measurements were carried out using automated near real-time apparatus called the Kinetic Sequential Sampling (KSS) system. KSS system is essentially an electronically-controlled lift carrying a real-time particle monitor for sampling air sequentially, at different heights within the breathing zone, which includes all heights within the surface layer of a street canyon at which people may breathe. Data is automatically logged at the different receptor levels, for the determination of the average vertical concentration profile of airborne particulate matter. For measuring the airborne particle concentration, a Grimm Dust Monitor 1.104/5 was used. The recorded data also allows for time series analysis of airborne particulate matter concentration at different heights. Time series data and hourly-average vertical concentration profiles in the boundary layer of the confines of a street are thought to be mainly determined by traffic emissions and traffic associated processes. Hence the measured data were compared with results of a street canyon emission-dispersion model in time and space. This Street Level Air Quality (SLAQ) model employs the plume-box technique and includes modules for simulating vehicle-generated effects such as thermally- and mechanically-generated turbulence and resuspension of road dust. Environmental processes, such as turbulence resulting from surface sensible heat and the formation of sulphate aerosol from sulphur dioxide exhaust emissions, are taken into account. The paper presents an outline description of the measuring technique and model used, and a comparison of the measured and modelled data.

Air Pollutants↗

Measuring and modelling the airborne particulate matter mass concentration field in the street environment: model overview and evaluation.

This paper discusses the outline structure and preliminary evaluation of an emission-dispersion model for predicting the temporal and spatial distribution of vehicle-derived airborne particulate matter mass concentration in street canyons. The model is called Street Level Air Quality (SLAQ). SLAQ is semi-empirical, in that it uses not only results from field and wind tunnel experiments but also theory and models derived from multiple runs of numerical routines in order to simulate the basic physical processes within the street canyon. A combination of a plume model, for the direct contribution of vehicle exhaust, and a box model for the recirculating part of the pollutants in the street, is used to predict concentration for receptors within the canyon. Emission rates of vehicle-derived particulate matter are calculated within SLAQ, which serve as input to the dispersion module. Exhaust emission rates are scaled element by element along the street for each of the lanes according to the direction of traffic flow to account for modal operation of vehicles near signalised intersections. This refinement allows SLAQ to account for non-uniformity in along-canyon emission rates and to model a street that has several intersections along its length. Thermal turbulence due to environmental surface sensible heat and vehicle-generated heat is accounted for in the model. Other features of SLAQ include correction for the urban heat island effect, dry deposition, wet deposition, particle settling and estimation of wind direction standard deviation, when this latter data is not available. SLAQ has been evaluated in a street in Loughborough, Leicestershire, United Kingdom and correlation coefficient of 0.8 between the modelled and measured concentrations has been obtained.

Aerosols↗

Indoor and outdoor measurements of vertical concentration profiles of airborne particulate matter.

Vertical concentration profiles of various particle size ranges of airborne particulate matter were measured from ground level up to 3 m, in outdoor and indoor environments. Indoor measurements were carried out in an electronics workshop, while two outdoor environments were chosen: a street canyon cutting across a town and an open field situated in a semi-rural environment. The novel measurement technique employed in this experimental work, which can also be used to determine vertical concentration gradients of pollutants other than airborne particles in different environments, is given particular attention. Analyses of the collected data for the environments considered are presented and some conclusions and plausible explanations of the profiles are discussed. The workshop and street canyon environments exhibited larger concentrations and vertical concentration gradients as compared to the sports field. This indicates that people breathing at different heights are subjected to different concentrations of airborne particulate matter, which has implications for sitting air pollution monitors intended for protection of public health and estimation of human exposure.

Air Pollution↗

Kinetic sequential sampling (KSS) system: an automated sampling system for measuring vertical concentration profiles of airborne particles.

An electronically controlled lift system carrying a real-time particle monitor has been developed for sampling air sequentially, at different heights within the breathing zone. Data are automatically logged at the different receptor levels, for the determination of average vertical concentration profiles of airborne particulate matter. The system is easy to operate, portable, and easily extended to different heights or modified for use with other types of monitors (e.g., a portable CO analyzer). For measuring airborne particle concentrations, a Grimm Dust Monitor 1.104/5 was used. The results of trial runs, which were carried out indoors and in a relatively open semi-rural area, are presented, and applications of the kinetic sequential sampling (KSS) system are discussed.

Air Pollutants, Occupational↗