Esophagitis and anticonvulsant hypersensitivity syndrome.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Milano.
Explore the source record for details and available documents.
Gastroenteric bleeding due to angiodysplasia (AD) is a relatively common occurrence in patients with end-stage renal failure. Gastric and colon angiodysplasic lesions can be easily revealed by endoscopic procedures, whereas lesions of the small intestine are more difficult to detect. Imaging modalities used in the diagnostic imaging algorithm for the detection of small-bowel AD, include non-invasive methods like enema-helical computer tomography,(99m)Tc-labelled red blood cell scintigraphy, and angiography, and invasive methods such as intraoperative enteroscopy. We report the cases of 3 hemodialysis patients with recurrent episodes of gastrointestinal bleeding, caused by small-bowel AD diagnosed by means of wireless-capsule endoscopy. In all cases, previous gastroscopy and colonoscopy were unrevealing. Wireless-capsule endoscopy consists in swallowing a capsule endoscope (11 mmx27 mm) which contains a miniature video camera, a light source, batteries, and a radio transmitter. Video images are transmitted by means of radio telemetry to aerials taped to the body that allow images to be captured. Moving images from a period as long as 6 h are stored on a portable recorder. Wireless-capsule endoscopy may prove valuable in the assessment of gastrointestinal bleeding in uremic patients with unrevealing results at gastroscopy and colonoscopy.
BACKGROUND: The resistance of Helicobacter pylori to antibiotics has been advocated as a major cause of treatment failure, and antimicrobial sensitivity testing has been proposed to improve efficacy; however, its role before first-line therapy has not been investigated in detail. AIM: To assess whether antimicrobial sensitivity testing improves the eradication rate of first-line anti-Helicobacter treatments and to compare the effectiveness of ranitidine bismuth citrate and omeprazole in the presence of H. pylori resistance to antibiotics. METHODS: Two hundred and forty-two patients were assigned to either empirical or antimicrobial sensitivity testing-based treatment; within each group, subjects were further randomized to receive ranitidine bismuth citrate, 400 mg b.d., tinidazole, 500 mg b.d., and clarithromycin, 500 mg b.d., or omeprazole, 20 mg b.d., clarithromycin, 500 mg b.d., and amoxicillin, 1 g b.d., for 1 week, with substitution of the resistant antibiotic in the antimicrobial sensitivity testing-based treatment group. RESULTS: Eradication rates were 67% [confidence interval (CI), 55-79%] in the empirical treatment group and 76% (CI, 65-87%) in the antimicrobial sensitivity testing-based group (P=N.S.). The overall success rate was 60% (CI, 51-69%) with omeprazole and 82% (CI, 73-91%) with ranitidine bismuth citrate (P<0.03); the latter overcame antibiotic resistance in 12 of 15 strains vs. zero of eight strains by omeprazole. CONCLUSIONS: Antimicrobial sensitivity testing before first-line treatment does not improve the eradication rate, which is greater when ranitidine bismuth citrate is included in the treatment.
The TB Structural Genomics Consortium is an organization devoted to encouraging, coordinating, and facilitating the determination and analysis of structures of proteins from Mycobacterium tuberculosis. The Consortium members hope to work together with other M. tuberculosis researchers to identify M. tuberculosis proteins for which structural information could provide important biological information, to analyze and interpret structures of M. tuberculosis proteins, and to work collaboratively to test ideas about M. tuberculosis protein function that are suggested by structure or related to structural information. This review describes the TB Structural Genomics Consortium and some of the proteins for which the Consortium is in the progress of determining three-dimensional structures.
BACKGROUND AND AIM: In vitro, methotrexate (MTX) is the best modulator for bolus 5-fluorouracil (5FU), whereas folinic acid (FA) is the best for continuous infusion. We evaluated the effect of 5FU modulated by both MTX (bolus administration) and FA (continuous infusion) as second-line treatment of patients with metastatic colorectal cancer. PATIENTS AND METHODS: Entry criteria were: at least one 5FU-based chemotherapy regimen as first-line treatment for metastatic disease, or progression within twelve months after 5FU-containing adjuvant therapy. Treatment schedule: MTX 200 mg/m2 i.v. days 1 and 15; 5FU 600 mg/m2 i.v. bolus, days 2 and 16; 5FU 200 mg/m2 i.v. continuous infusion for 21 days, starting on day 29; FA 20 mg/m2 i.v. bolus weekly during the three weeks of 5FU infusion. Cycles were repeated every 56 days. The primary end-point was tumour control rate, including partial responses and stabilizations. RESULTS: 34/35 patients enrolled were evaluable for response. Five (14.7%) had a partial response, 13 (38.2%) disease stabilization, and 16 (47.1%) progressed; tumour control rate was 52.9%. Median TTP was 5.8 months (95% CI 4.03-7.83); 29 patients had died. Median OAS was 15.9 months (95% CI 8.8-21.9). Toxicity was mild. CONCLUSIONS: The regimen constituted by 5FU modulated by MTX (bolus administration) and FA (continuous infusion) is active as second-line treatment of metastatic colorectal cancer.
We report a patient who presented with paraprosthetic leak complicated by dissection of the interatrial septum after mitral valve replacement. A review of the literature provides confirmation that only 3 cases have been previously reported of this potential, albeit extremely rare, complication of prosthetic mitral valve replacement. Prosthesis oversizing and improper mitral annular handling appeared to be the predisposing factors of this complication.
The DNA region upstream of katG in Mycobacterium smegmatis was cloned and sequenced. The furA gene, highly homologous to Mycobacterium tuberculosis furA, mapped in this region. The furA-katG organization appears to be conserved among several mycobacteria. The transcription pattern of furA and katG in M. smegmatis upon oxidative stress was analyzed by Northern blotting and primer extension. Although transcription of both furA and katG was induced upon oxidative stress, transcripts covering both genes could not be identified either by Northern blotting or by reverse transcriptase PCR. Specific transcripts and 5' ends were identified for furA and katG, respectively. By cloning M. smegmatis and M. tuberculosis DNA regions upstream of a reporter gene, we demonstrated the presence of two promoters, pfurA, located immediately upstream of the furA gene, and pkatG, located within the terminal part of the furA coding sequence. Transcription from pfurA was induced upon oxidative stress. A 23-bp sequence overlapping the pfurA -35 region is highly conserved among mycobacteria and streptomycetes and might be involved in controlling pfurA activity. Transcription from a cloned pkatG, lacking the upstream pfurA region, was not induced upon oxidative stress, suggesting a cis-acting regulatory role of this region.
The effect of different bowel preparations on residual fluid during computed tomographic (CT) colonography was evaluated. Forty-two patients received either a polyethylene glycol electrolyte solution preparation or a phospho-soda preparation the day prior to CT colonography. The amount of residual fluid was calculated for each patient. On average, a phospho-soda preparation provided significantly less residual fluid than a polyethylene glycol electrolyte solution preparation.
Explore the source record for details and available documents.
BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the medium-term results of aortic valve replacement (AVR), mitral valve replacement (MVR) and double valve replacement (DVR) with the Sorin Bicarbon prosthesis. METHODS: A total of 990 patients (568 men, 422 women; mean age 60+/-10 years; range: 20-86 years) was reviewed who received 1,108 Sorin Bicarbon prostheses between 1992 and 1998 at three institutions. AVR was performed in 541 patients (55%), MVR in 330 (33%) and DVR in 119 (12%). Concomitant procedures, mainly coronary artery grafting, were performed in 222 patients (22%). Follow up was 98% complete; total cumulative follow up was 3,091 patient-years. RESULTS: Hospital mortality was 3.7% (n = 37). There were 49 late deaths; actuarial survival at seven years was 88+/-2% after AVR, 86+/-5% after MVR, and 78+/-8% after DVR. At last follow up, 915 survivors were in NYHA functional class I or II. At seven years, actuarial freedom from valve-related deaths, valve thrombosis, embolism and bleeding respectively was 96+/-1%, 99+/-1%, 93+/-2% and 91+/-3% after AVR; 97+/-2%, 97+/-3%, 90+/-3% and 86+/-7% after MVR; and 92+/-6%, 98+/-1%, 64+/-2% and 82+/-2% after DVR. Reoperation was required in 20 patients (due to valve thrombosis in six, endocarditis in five and periprosthetic leak in nine). At seven years, actuarial freedom from reoperation was 97+/-1%, 96+/-2% and 84+/-9% after AVR, MVR and DVR, respectively; actuarial freedom from endocarditis was 99+/-1%, 99+/-1% and 95+/-5%. Nine patients experienced a nonstructural valve dysfunction (all periprosthetic leak), while no cases of structural failure were observed. CONCLUSION: The Sorin Bicarbon prosthesis has shown good medium-term results with regard to clinical improvement, and low incidence of valve-related complications. Thus, it appears to be a reliable valve substitute when the use of a mechanical prosthesis is indicated.
BACKGROUND: Aortic valve replacement in elderly patients with a small aortic annulus may pose difficult problems in terms of prosthesis selection. We have evaluated the hemodynamic performance of the 21-mm Carpentier-Edwards Perimount bioprosthesis implanted in elderly patients. METHODS: From July 1996 to June 1998, 19 patients (17 women and 2 men, mean age 76+/-4 years and mean body surface area 1.73+/-0.13 m2), had aortic valve replacement with a 21-mm Carpentier-Edwards Perimount bioprosthesis. The hemodynamic performance of the valve was evaluated in 16 patients, who completed at least a 6-month follow-up interval, with transthoracic color-Doppler echocardiography with particular reference to peak and mean transprosthetic gradients, effective orifice area index, and regression of left ventricular mass index. RESULTS: There were no late deaths and no major postoperative complications. At a mean follow-up of 12+/-7 months, compared to discharge, all patients showed clinical improvement with a significant reduction of peak gradient (from 23+/-4 to 21+/-6 mm Hg, p = 0.04) and left ventricular mass index (from 181+/-23 to 153+/-20 g/m2; p<0.001), whereas mean gradient (from 13+/-3 to 13+/-4 mm Hg, p = not significant) and effective orifice area index (from 1.12+/-0.34 to 1.13+/-0.28 cm2/m2, p = not significant) remained substantially unchanged. CONCLUSIONS: The use of a 21-mm Carpentier-Edwards Perimount bioprosthesis is associated with low transprosthetic gradients and significant reduction in left ventricular hypertrophy after aortic valve replacement. The results of our study suggest that a 21-m Carpentier-Edwards Perimount bioprosthesis should be considered a valid option in elderly patients with aortic valve disease and a small aortic annulus.
Explore the source record for details and available documents.
The association of calcific aortic valve disease and isolated coronary ostial stenosis is rare. A 80-year-old woman was found to have severe aortic stenosis with critical narrowing of the ostium of the left main coronary artery. She was successfully managed by simultaneous aortic valve replacement and patch angioplasty of the left main coronary artery, using a patch of autologous pericardium fixed in glutaraldehyde. Angiographic control at 1 month coupled with intravascular echographic imaging showed adequate relief of the ostial stenosis and patency of the left main trunk.
OBJECTIVE: We compared the findings of time-efficient CT colonography with complete two-dimensional (2D) and three-dimensional (3D) CT colonography and conventional colonoscopy in detecting colorectal polyps. SUBJECTS AND METHODS: Forty-two patients undergoing colonoscopy screening were examined with CT colonography before endoscopy. Data were examined following one of two methods. In method 1, axial 2D data sets were examined in a cine mode. If findings were suggestive of abnormality, focal areas were examined with 3D CT colonography. In method 2, data sets were examined exactly as in method 1, and subsequent to that review, data sets were examined with simultaneous 3D "fly-through" CT colonography (surface-rendered images) and multiplanar reformatted images. The time required to examine CT colonography using each technique was recorded and abnormal findings were documented. Results of methods 1 and 2 were compared with findings on colonoscopy. RESULTS: Colonoscopy detected 16 polyps in 13 patients (polyp size, 2-10 mm). Ten polyps measured 5 mm or less, five measured between 6 and 9 mm, and one measured 10 mm or more. Using method 1, two of 10 polyps measuring less than 5 mm, three of five polyps measuring between 6 and 9 mm, and one polyp measuring 10 mm were detected. We noted no false-positive polyps. Average evaluation time was 16 min. With method 2, the same polyps were seen as with method 1. No additional polyps were detected, and the average evaluation time was 40 min. CONCLUSION: Axial 2D CT colonography can be performed quickly and is comparable with complete 2D and 3D CT colonography in detecting colorectal polyps.
BACKGROUND AND AIM OF THE STUDY: Mitral valve repair (MVR) is the treatment of choice in patients with degenerative valve disease. However, controversy persists as to whether mitral valve annuloplasty should always be included as part of the reconstructive procedure. METHODS: The records of 62 consecutive patients undergoing MVR for degenerative disease between January 1994 and December 1996 were reviewed. Four different annuloplasty techniques were associated with various MVR procedures: local posterior annuloplasty (group 1, n = 10), rigid Carpentier ring (group 2, n = 20), Duran ring (group 3, n = 17), and posterior annular plication with autologous pericardium (group 4, n = 15). The four patient groups were similar in terms of preoperative clinical and echocardiographic characteristics. Serial clinical and echocardiographic follow up was performed to assess functional status and stability of repair. RESULTS: There were no early or late deaths. Mean follow up in the entire patient series was 31 +/- 12 months. One patient in group 2 required reoperation 14 months after MVR. In all groups there was a significant improvement in NYHA functional class (from 2.7 +/- 0.6 to 0.9 +/- 0.5, p <0.001), with a reduction of left ventricular end-diastolic and end-systolic volumes (154 +/- 50 ml to 105 +/- 33 ml, p <0.001; and 64 +/- 23 ml to 52 +/- 22 ml, p <0.001). In patients of groups 2, 3 and 4, residual mitral incompetence at follow up (0.8 +/- 0.9 in group 2, 0.8 +/- 0.7 in group 3, and 0.2 +/- 0.6 in group 4) was not significantly different from discharge. However, in group 1, a higher degree of residual mitral regurgitation was present at discharge (0.9 +/- 0.6) with a trend to progress at follow up (1.6 +/- 0.5). CONCLUSION: In patients with degenerative mitral valve disease, MVR provides clinical and functional improvement. Techniques of stabilization of the entire posterior mitral annulus achieve better early and medium-term results, and should be always considered as part of MVR. Autologous pericardium appears to be an excellent annuloplasty material, though its apparent superiority over synthetic rings must be confirmed at longer follow up.
The use of a composite graft is an established treatment for patients with aortic valve disease and ascending aortic aneurysms. Since bleeding from suture lines is a potential complication of this procedure, we modified the technique and evaluated the effect on hemostasis. From January 1994 through December 1998, 35 patients underwent composite aortic graft replacement for chronic aortic disease. In the first 16 patients (Group 1), we used the standard open technique, with excision of the aortic aneurysm and anastomosis of aortic buttons containing the coronary ostia to the vascular graft. In the next 19 patients (Group 2), we modified the technique by placing an additional suture at the proximal graft anastomosis and harvesting large coronary buttons that were then attached to the graft by an "endo-button" buttress method. There were no operative deaths; the actuarial survival rate at 36 months was 92% +/- 5%. Between groups 1 and 2, a significant difference was found in postoperative bleeding (1,052 + 433 mL vs 806 +/- 257 mL, respectively; p = 0.02) and in number of blood transfusions required (2.1 +/- 2.0 units vs 0.4 +/- 0.7 units, respectively; p = 0.002). Multivariate analysis showed that the surgical technique used in Group 1 was the only independent risk factor for postoperative bleeding of 1,000 mL or more (p = 0.01) and for transfusion requirements of 3 or more units of blood (p = 0.004). Composite aortic valve and root replacement can be accomplished with excellent results. Technical modifications may reduce bleeding complications and related morbidity significantly
Explore the source record for details and available documents.
A 34-year-old man had development of an aortobronchial fistula 17 years after patch aortoplasty for correction of aortic coarctation and 5 years after blunt chest trauma, an unusual combination of predisposing factors. The clinical presentation, characterized by dysphonia and recurrent hemoptysis, and the surgical findings suggested the posttraumatic origin of the fistula, which was successfully managed by aortic resection and graft interposition under simple aortic cross-clamping, associated with partial pulmonary lobectomy. When hemoptysis occurs in a patient with a history of an aortic thoracic procedure, the presence of an aortobronchial fistula should be suspected. Early diagnosis offers the only possibility of recovery through a lifesaving surgical procedure.