Correlation between cidofovir-associated uveitis and failing immunorestoration during HAART.

In order to elucidate the factors related to the development of cidofovir-associated uveitis in AIDS patients receiving highly active antiretroviral therapy, the characteristics of 17 AIDS patients with Cytomegalovirus retinitis ( n=10) or progressive multifocal leukoencephalopathy ( n=7) treated with intravenous cidofovir were evaluated. Six cases of cidofovir-associated uveitis occurred among the patients with retinitis. No cases were detected among the patients with progressive multifocal leukoencephalopathy. Stepwise linear regression analysis revealed a significantly higher HIV-viremia level ( P=0.01) and a significantly lower CD4+ cell count ( P=0.009) among cases at the time of uveitis onset in comparison with patients who did not develop uveitis. Thus, cidofovir-associated uveitis seems to occur more frequently in AIDS patients with retinitis in whom highly active antiretroviral therapy fails to restore immunity.

Acquired Immunodeficiency Syndrome↗

Retinal sensitivity to flicker modulation: reduced by early age-related maculopathy.

PURPOSE: To evaluate retinal, cone-mediated flicker sensitivity (CFS) in age-related maculopathy (ARM) by quantifying response gain and threshold of the focal electroretinogram (FERG) to flicker modulation. METHODS: Nineteen patients with ARM (visual acuity > or =20/30) and 11 age-matched control subjects were examined. Twelve patients had less than 20 soft drusen in the macular region and no hyper-/hypopigmentation (early lesion), whereas seven had more than 20 soft drusen and/or focal hyper-/hypopigmentation (advanced lesion). Macular (18 degree ) FERGs were elicited by a sinusoidally flickering (41 Hz) uniform field (on a light-adapting background) whose modulation depth was varied between 16.5% and 94%. Amplitude and phase of the response's fundamental harmonic were measured. RESULTS: In both control subjects and patients with ARM, log FERG amplitude increased with log stimulus modulation depth with a straight line (power law) relation. However, the slope (or gain) of the function was, on average, steeper in control subjects than in patients with either early or advanced lesions. Mean FERG threshold, estimated from the value of the log modulation depth that yielded a criterion response, did not differ between control subjects and patients with early lesions but was increased (0.35 log units) compared with control subjects in those with advanced lesions. In both patient groups, but not in control subjects, mean FERG phase tended to delay with decreasing stimulus modulation depth. CONCLUSIONS: Retinal CFS losses can be detected in ARM by evaluating the FERG as a function of flicker modulation depth. Reduced response gain and phase delays, with normal thresholds, are associated with early lesions. Increased response thresholds, in addition to gain and phase abnormalities, may reflect more advanced lesions. Evaluating CFS by FERG may directly document different stages of macular dysfunction in ARM.

Aged↗

Macular flicker electroretinograms in Best vitelliform dystrophy.

PURPOSE: The aim of this study was to evaluate the function of the neurosensory retina in Best vitelliform macular dystrophy (BMD) by recording the focal electroretinogram (ERG) fundamental and 2nd harmonic components, which are known to be dominated by receptoral and postreceptoral activity, respectively. METHODS: FERGs were recorded in response to a uniform field (9 x 9 deg) flickered sinusoidally at either 8 Hz or 32 Hz (peak frequencies for the 2nd and fundamental harmonic, respectively). The fundamental component of the response to the 32-Hz stimulus and the 2nd harmonic of the response to the 8-Hz stimulus were measured in their amplitudes and phases. The fundamental-2nd harmonic amplitude ratio was taken as an index of the relative changes in the FERG components. Eleven patients with BMD and vitelliform stage macular lesions were evaluated. Results were compared with those obtained from 13 patients with Type 2 Stargardt macular dystrophy (STD) according to the Noble and Carr Classification, and 29 normal control subjects. Four BMD and four STD patients were also followed electrophysiologically over a 48 month period. RESULTS: Compared to controls, BMD patients showed losses of both FERG fundamental and 2nd harmonic amplitudes, and an increase in the fundamental and increase in the fundamental-2nd harmonic ratio. STD patients also showed losses of both fundamental and 2nd harmonic, but the fundamental-2nd harmonic ratio was normal. In BMD patients, but not in those with STD, the fundamental amplitude tended to decrease over the follow-up period. CONCLUSIONS: The results indicate that BMD involves neurosensory abnormalities early in the disease process. The increased fundamental-2nd harmonic ratio suggests that a postreceptoral dysfunction may be present in addition to that of photoreceptors. This differs from STD, where losses appear to affect primarily the receptoral retina. Receptoral losses in BMD may progress throughout the medium-term follow up.

Adult↗

Macular electroretinograms to flicker and pattern stimulation in lamellar macular holes.

Steady-state macular (9 degrees x 9 degrees) electroretinograms in response to either sinusoidal flicker (focal electroretinogram) or counterphased sinusoidal gratings (pattern electroretinogram) were recorded in 14 patients with inner lamellar macular holes, in 4 patients with full-thickness macular holes and in 14 age-matched controls. Fourier analysis of focal and pattern electroretinograms yielded three main components: a first and a second harmonic to flicker, and a second harmonic to pattern. Recent evidence indicates that the first harmonic to flicker is of receptoral origin, whereas the flicker and pattern second harmonics represent, at least in part, the activity of different generators in the inner retina. When compared to controls, patients with inner lamellar holes showed significant amplitude reduction and phase delay for both flicker and pattern second harmonics, but not for the flicker first harmonic. Patients with full-thickness holes showed significant amplitude reduction also for the flicker first harmonic. These results indicate a prevalent functional involvement of the inner retina in lamellar macular holes, which can be clinically detected by evaluating focal and pattern electroretinogram second harmonics.

Adult↗

Nonselective loss of contrast sensitivity in visual system testing in early type I diabetes.

OBJECTIVE: Psychophysical methods in patients with diabetes mellitus reveal deficits of central or foveal vision. Our aim was to evaluate the contrast-sensitivity thresholds in 24 insulin-dependent (type I) diabetic patients with a short disease duration and without retinopathy, taking into account metabolic control. RESEARCH DESIGN AND METHODS: The control group consisted of age-matched nondiabetic subjects. None had visual or systemic symptoms. Contrast sensitivity measured at eight different spatial frequencies to sinusoidal bar patterns of 0.6-12.2 cycles/deg can detect functional defects in the spatially sensitive retinal ganglion cells or in higher visual pathways. We performed two different temporal types of contrast-sensitivity testing, dynamic (8 Hz) and static (0 Hz). RESULTS: Significant losses with dynamic contrast-sensitivity test at all but the highest spatial frequencies (i.e., 12.2 cycles/deg) were shown, whereas there was significant attenuation of contrast sensitivity at five spatial frequencies (1.0, 1.4, 2.2, 7.1, and 9.6 cycles/deg) in the static mode. Grating losses (less than 2SD of control means) of contrast sensitivity were found in 33.3% (dynamic) and in 72.9% (static) of eyes of diabetic patients. HbA1c values were positively correlated at variable spatial frequencies (1.0, 1.4, and 2.2 cycles/deg for dynamic test and 0.6, 1.0, 1.4, 2.2, 4.8, and 7.1 cycles/deg for static test). CONCLUSIONS: Our results suggest an early, generally nonselective neuronal damage of visual pathways that occurs before the onset of clinically detectable retinopathy. The visual deficit may be related directly to the effects of diabetes; repetitive minor hypoglycemic insults may contribute more than a marked hyperglycemic condition to the mechanisms underlying physiological changes along the optic nerve.

Adult↗

Steady-state pattern electroretinogram in insulin-dependent diabetics with no or minimal retinopathy.

Steady-state pattern electroretinogram (PERG) in response to sinusoidal gratings (1.7 c/deg spatial frequency; 9 x 9 deg field size) temporally modulated (sinusoidally) at 8 Hz were recorded in 40 insulin-dependent diabetics and 28 age-matched normal subjects. Visual acuity was greater than or equal to 20/20 in all 40 patients; 31 (62 eyes) showed no sign of retinopathy and nine (18 eyes) showed a few microaneurysms on fluorescein angiography. Insulin-dependent diabetics showed a significant reduction in the PERG mean amplitude as compared with age-matched control subjects (one-way analysis of variance: p less than 0.0001). Significant differences were observed between normals and diabetics without retinopathy (Scheffé test: p less than 0.0001), normals and diabetics with early retinopathy (Scheffé test: p less than 0.0001), no retinopathy and early retinopathy patients (Scheffé test: p less than 0.05). In diabetics without retinopathy multifactorial analysis of variance revealed a significant effect of age of onset of the disease (p less than 0.01) and an interaction effect between age of onset and duration (p less than 0.001) on PERG amplitude. These results suggest a possible use of the steady-state PERG to detect early macular dysfunction in insulin-dependent diabetics.

Adult↗

Changes in spatial tuning of the pattern electroretinogram with age.

Experimental and clinical studies have demonstrated that the electroretinogram in response to periodical patterns alternating in contrast at constant mean luminance (pattern reversal ERG, P-ERG), is correlated with ganglion cell activity. Senile functional changes of these neurons might be therefore investigated by the P-ERG technique. Steady-state P-ERGs (8 Hz) in response to sinusoidal gratings of different spatial frequencies (0.6-6.8 c/d) were recorded in normal subjects ranging over 50 year age span. The P-ERG amplitude as a function of stimulus spatial frequency shows a maximum between 1.2-1.7 c/d and attenuation at higher and lower spatial frequencies (spatial tuning). The P-ERGs of the older subjects are reduced in amplitute, as compared to those of the younger ones, over the whole range of spatial frequency. This reduction is more marked at intermediate spatial frequencies resulting in a shallower tuning.

Adult↗