Continuous veno-venous hemofiltration in critically ill patients with multiple organ failure.

18 critically ill patients, with multiple organ failure (MOF) (from shock either septic, n = 15, or cardiogenic, n = 3), oliguria and increase in BUN and creatinine were treated with pump driven, high flux continuous veno-venous hemofiltration (CVVH). Replacement fluids were administered in predilution mode. All patients were under respiratory support and vasoactive drugs, and received early nutritional support (N input: 0.2-0.3 g/kg/day). Mean duration of treatment was 9.2 days and mean ultrafiltrate production was 21.4 l/day; treatment resulted in a significant reduction of both urea nitrogen and creatinine blood levels (-20 and -40% of initial values respectively) in spite of a very severe catabolism. The total amount of urea nitrogen removed through CVVH ranged from 15 to 73 g/day (mean 33.5), the median value of urea nitrogen clearance was 12.8 ml/min with a median ultrafiltration coefficient of 0.8. The mean duration of hemofilters was 69 hours (38-108); the efficacy of filters remained stable throughout the entire lifespan and changes were made in case of sudden decrease of ultrafiltration (< ml/min). No major complication was observed in over than 4000 hours of treatment. Pump driven, high flux CVVH proved effective in the control of water electrolyte balance and metabolic homeostasis in a group of critically ill, hemodynamically unstable, catabolic patients with MOF and acute renal failure. In no case we had to add intermittent hemodialysis or to use hemodiafiltration. The constant extracorporeal blood flow and the stable efficacy of hemofilters allowed an easy control of the overall effectiveness of this technique.

Adult

[Intensive care of AIDS patients. Clinical experience].

Six patients with AIDS and severe respiratory failure from diffuse interstitial pneumonia, have been treated in one year in ICU. The authors describe diagnostic and therapeutic characteristics and management problems, underlining the good results in the short and medium term.

Acquired Immunodeficiency Syndrome

[Automatic fluid control during high-flow continuous hemofiltration: the Equaline system].

OBJECTIVE: To describe the use of an automatic fluid control system, Equaline, during high flux continuous hemofiltration. DESIGN: Prospective descriptive study. SETTING: General intensive care unit in a general hospital. PATIENTS: 15 consecutive patients suffering from septic shock, hypercatabolic with acute renal failure. INTERVENTION: Pump driven continuous veno-venous hemofiltration (PDCVVH) with high flux was performed. All pts were intubated, under mechanical ventilation and treated with vasoactive agents for hemodynamic instability. Fluid balance was achieved with an automatic fluid control system, Equaline, on daily basis according to clinical needs. MEASURES: Length of treatment, daily amount of ultrafiltrate and urea removal, urea and creatinine blood level before and after the treatment were registered. RESULTS: Age was 59.1 years, SAPS 17.2. Patients were treated for an average period of 9 days obtaining a daily ultrafiltrate production of 21.4 L. In all pts, though the high catabolism (daily nitrogen production > 30 g), there was a significant decrease of urea and creatinine concentration. CONCLUSION: Equaline system was able to maintain intravascular volume in the face of high ultrafiltration rate avoiding clinically important discrepancies between ultrafiltrate formation and fluid replacement. We conclude that PDCVVH management is greatly improved with use of such servo-controlled feedback system.

Acute Kidney Injury