PubMed HealthSearch

Biomedical subjects

A Montaser

Publications and source records attributed to A Montaser.

4 recordsLinked to original sources

Comparison of copper binding components in dog serum with those in other species.

The copper content of dog serum and its distribution to copper binding proteins was compared with that of rat and mouse. Total serum Cu concentrations of dogs and mice were one third those of the rat. Plasma ceruloplasmin, determined by azide-inhibitable oxidase activity with two substrates, was 8-fold less in the dog and 9- to 20-fold less in the mouse than in the rat, and, in both dogs and mice, there was 70-75% less ceruloplasmin Cu, determined by atomic absorption after gel filtration. In the dog, the largest proportion of total and exchangeable serum Cu was with the transcuprein fraction. Only one third as much Cu was with albumin in the dog (and mouse) versus the rat, and this was released much more readily through dialysis. In dogs and mice, the exchangeable (nonceruloplasmin) serum copper pool was half the size of that in rats and humans. Especially in the mouse (but also in rats and dogs), a small proportion of the exchangeable pool appeared bound to ferroxidase II. We conclude that the dog may rely more on transcuprein and low molecular weight complexes and less on albumin and ceruloplasmin for transport of copper to cells.

Adult

Thimble glass frit nebulizer for atomic spectrometry.

A thimble-shaped glass frit nebulizer has been developed for atomic spectrometry. The thimble glass frit was pressurized internally by gases such as helium (He) or argon (Ar) while the test solution was applied externally to the frit. The pressurized gas exited through the pores of the glass frit and shattered the thin liquid film flowing on the surface of the thimble-shaped device to form small droplets. A small spray chamber surrounded the nebulizer to remove the large droplets. Small droplets were then introduced into inductively coupled plasmas (ICP) sustained in either Ar or He. To reduce the memory effect noted in the frit-type nebulizers, a clean-out system was also devised. Detection limits, signal-to-background ratios (S/B), precision, memory effects, noise power spectra (NPS), and particle size distributions measured with the new nebulizer were compared to those of disk and cylindrical glass frit nebulizers and the commonly used pneumatic nebulizer for Ar ICP atomic emission spectrometry (AES). Analytical performance was also measured for He ICP by using frit-type nebulizers and an ultrasonic nebulizer.

Nebulizers and Vaporizers