PubMed Health⌕ Search

Biomedical subjects

A Nappi

Publications and source records attributed to A Nappi.

At least 19 recordsLinked to original sources

[Relationship between exercise capacity and left ventricular function at rest in patients with heart insufficiency: radionuclide continuous monitoring of left ventricular function].

PURPOSE: To evaluate the relationship of systolic and diastolic function at rest to exercise capacity. MATERIAL AND METHODS: Seventeen patients with ischemic heart failure were included in the study. Ambulatory left ventricular monitoring at rest and during upright exercise with combined analysis of pulmonary gas exchange was performed. Ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, and peak filling rate were measured. RESULTS: Significant positive correlations were found between rest ejection fraction and peak oxygen consumption (r = .60, p < .01), peak cardiac output (r = .77, p < .0001), peak stroke volume (r = .67, p < .005), and peak ejection fraction (r = .69, p < .005). On the other hand, peak filling rate at rest showed a significant inverse correlation with peak end-diastolic (r = -.48, p < .05) and end-systolic (r = -.66, p < .005) volumes. The patients were then subgrouped into two groups according to their rest ejection fraction (lower or higher than 40%). In the group with ejection fraction less than 40% a significant correlation was observed between rest ejection fraction and both peak stroke volume (r = .66, p < .05) and peak ejection fraction (r = .69, p < .05). In the same group of patients an inverse correlation was found between peak filling rate and both end-diastolic (r = -0.65, p < .05) and end-systolic (r = -.82, p < .005) volumes. CONCLUSIONS: The results of the present study suggest that exercise capacity is related to left ventricular function at rest and that rest diastolic function might be a determinant of left ventricular function during exercise in patients with heart failure.

Exercise Tolerance↗

Ambulatory monitoring of left ventricular function: walk and bicycle exercise in congestive heart failure.

UNLABELLED: The aim of this study was to assess changes in left ventricular (LV) function during 6-min walk test and cardiopulmonary exercise by continuous radionuclide monitoring in patients with congestive heart failure (CHF). METHODS: Seventeen patients with CHF and 10 normal subjects underwent monitoring of LV function (Vest) during 6-min walk test and during bicycle exercise with combined analysis of pulmonary gas exchange. During cardiopulmonary exercise, all parameters of LV function were measured at rest, at the anaerobic threshold (AT) and at peak oxygen uptake (peak VO2). RESULTS: In the normal subjects, during the walk test, heart rate (HR), ejection fraction (EF), end-diastolic volume (EDV), cardiac output (CO) and stroke volume (SV) significantly increased from rest to peak (all p < 0.001), while end-systolic volume (ESV) significantly decreased from rest to peak (p < 0.001). In patients with CHF, during the walk test, HR, EDV, ESV and CO significantly increased from rest to peak (p < 0.001), EF significantly decreased from rest to peak (p < 0.001) and SV did not show significant change. During cardiopulmonary exercise, normal subjects showed a significant increase in HR and CO, from rest to AT and from AT to the peak VO2 (p < 0.001). EF, EDV and SV significantly increased from rest to AT (p < 0.001), with no significant change from AT to peak VO2. ESV decreased from rest to AT (p < 0.001), showing no significant change from AT to peak VO2. In patients with CHF, HR, CO, ESV and EDV increased significantly from rest to AT (p < 0.001) and from AT to peak VO2 (p < 0.001). EF and SV did not show significant changes from rest to AT, showing a significant decrease from AT to peak VO2 (p < 0.001). CONCLUSION: Vest can be used to evaluate cardiac responses during 6-min walk test and cardiopulmonary exercise in patients with CHF. In such patients, significant impairment of LV function is already present during submaximal physical exercise becoming more evident during the anaerobic phases of bicycle exercise.

Case-Control Studies↗

Adenosine coronary vasodilation in coronary artery disease: technetium-99m tetrofosmin myocardial tomography versus echocardiography.

UNLABELLED: This study compared the results of adenosine 99mTc-tetrofosmin cardiac tomography with those of adenosine echocardiography in identifying patients with coronary artery disease (CAD) and in localizing individual stenosed, coronary vessels. METHODS: Twenty-six consecutive patients with suspected or known CAD had simultaneous adenosine (140 micrograms/Kg/min intravenously) 99mTc-tetrofosmin tomography and two-dimensional echocardiography. All patients had coronary angiography within 4 wk from imaging studies. Regional 99mTc-tetrofosmin activity was quantitatively measured in 78 coronary vascular territories and echocardiographic left ventricular function was assessed in corresponding regions. RESULTS: At coronary angiography one patient had normal coronary vessels, 12 patients one-vessel and 13 had multivessel disease (> or = 50% luminal stenosis). Among the 25 patients with CAD, 22 showed perfusion defects at adenosine 99mTc-tetrofosmin tomography (sensitivity 88%) and 17 had abnormal echocardiographic study (sensitivity 68%, p < 0.05 versus 99mTc-tetrofosmin). Agreement for the identification of patients with CAD between adenosine 99mTc-tetrofosmin tomography and echocardiography was observed in 21 (81%) of the total 26 patients, with a kappa value of 0.45. Overall sensitivity, specificity and diagnostic accuracy for detection of individual stenosed vessels were 79%, 88% and 83% for 99mTc tetrofosmin and 57%, 68% and 61% (all p < 0.05 versus 99mTc-tetrofosmin) for echocardiography. Concordance between adenosine 99mTc-tetrofosmin tomography and echocardiography in the detection of individual stenosed coronary vessels was observed in 57 (73%) of the 78 vascular territories, with a kappa value of 0.36. CONCLUSION: Adenosine-induced coronary vasodilation associated with quantitative 99mTc-tetrofosmin tomography is more accurate than adenosine echocardiography in identifying patients with CAD and in detecting individual stenosed coronary vessels.

Adenosine↗

Influence of digitalis on left ventricular functional response to exercise in congestive heart failure.

This was a double-blind, placebo-controlled, crossover study designed to determine the influence of digitalis treatment on left ventricular (LV) response to physical exercise in patients with congestive heart failure (CHF). In 10 patients with CHF (ejection fraction 29 +/- 2%), LV function was assessed during upright bicycle exercise using an ambulatory radionuclide detector for continuous noninvasive monitoring of cardiac function. Exercise was performed during control conditions and after a 3-week treatment with digoxin (0.25 mg/day orally) or placebo. Ten normal volunteers matched for sex and age constituted the control group. In normals, exercise ejection fraction and end-diastolic volume increased (both p <0.001), while end-systolic volume decreased progressively (p <0.001). In control conditions, patients with CHF had a sharp increase in heart rate during exercise, while ejection fraction did not change; both end-diastolic and end-systolic volumes increased significantly (both p <0.001) during exercise. During digoxin treatment, heart rate response to exercise recorded in patients with CHF was comparable to that recorded in normal subjects. In addition, a significant increase in ejection fraction during exercise was detected (P <0.001), and the increase in end-systolic volume was significantly smaller than that observed in control conditions (p <0.05). When patients received placebo, the responses of LV function to exercise were comparable to those observed in control conditions. These findings demonstrate that digitalis has a favorable influence on LV functional adaptation to exercise in CHF.

Adult↗

Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease.

The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99mTc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (>/=50% luminal stenosis) (n=50) had an abnormal 99mTc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall sensitivity, specificity and diagnostic accuracy in the detection of individual stenosed vessels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P<0.05) in patients with single-vessel disease (n=21) than in those with multivessel disease (n=29). Sensitivity, specificity and accuracy for detecting individual diseased vessels were similar in patients without previous myocardial infarction (n=26) and in those with previous myocardial infarction (n=35). In myocardial territories related to non-infarcted areas (n=128), sensitivity and specificity in the detection of stenosed vessels were 70% and 95%, respectively. In infarcted areas (n=55), sensitivity and specificity in the detection of stenosed vessels were 85% (P=NS vs non-infarcted areas) and 75% (P<0.05 vs non-infarcted areas), respectively. Finally, sensitivity was significantly lower (P<0.05) in vascular territories supplied by vessels with moderate stenosis (50%-75%) than in those supplied by vessels with severe stenosis (>75%). The results of this study demonstrate that quantitative 1-day exercise-rest 99mTc-tetrofosmin single-photon emission tomographic imaging is a suitable and accurate technique to identify patients with CAD and to detect individual stenosed coronary vessels.

Case-Control Studies↗

Differential induction of antibacterial transcripts in Drosophila susceptible and resistant to parasitism by Leptopilina boulardi.

Two well-described elements of the immune response of insects include encapsulation of metazoan parasites (blood-cell-mediated) and the production of antibacterial peptides (humoral and/or cellular). However, the possible functional interrelationship between cellular encapsulation and antibacterial responses, and the extent to which the two components may be co-regulated, are poorly understood. We used a novel approach involving strains of Drosophila resistant (R) or susceptible (S) to the wasp parasitoid Leptopilina boulardi to study the expression of three genes involved in the antibacterial response: Dorsal-related immunity factor (Dif), Cecropin (CecA1) and Diptericin (Dip). Both S and R strains produced high levels of all antibacterial transcripts upon bacterial injection. However, when parasitized the R strain showed no induction whilst the S strain did. This lack of antibacterial transcript induction in the parasitized R strain not only clarifies the separation of these two types of immune response but also raises the fascinating possibility of a link in their genetic regulation.

Animals↗

[Tetrofosmin: a new compound labeled with 99mTc for the study of myocardial perfusion. Correlations with coronary anatomy in patients with suspected ischemic cardiopathy].

The aim of this study was to investigate the accuracy of quantitative one-day exercise-rest 99mTc tetrofosmin tomography in the identification of patients with suspected coronary artery disease (CAD) and in the detection of single stenosed coronary vessels. Sixty-one patients with suspected CAD and submitted to coronary angiography were examined. All patients were given 2 i.v. injections of 99mTc tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 hours after exercise (images 15-30 min after injection for both studies). All patients with CAD (> or = 50% luminal stenosis) (n = 50) had abnormal 99mTc tetrofosmin tomogram (100% sensitivity). Only one patient without CAD had abnormal 99mTc tetrofosmin tomogram (91% specificity). Overall sensitivity, specificity, and diagnostic accuracy in the detection of single stenosed vessels were 77%, 93% and 85%, respectively. No significant differences among single vascular areas were observed. Sensitivity and diagnostic accuracy in the identification of single stenosed coronary vessels were significantly higher (p < 0.05) in the patients with single-vessel disease (n = 21) than in those with multivessel disease (n = 29). Sensitivity, specificity and diagnostic accuracy in detecting single diseased vessels were similar in the patients without (n = 26) and in those with previous myocardial infarction (n = 35). The results of this study demonstrate that quantitative one-day exercise-rest 99mTc tetrofosmin SPECT imaging is a suitable and accurate technique to identify patients with suspected CAD and to detect single stenosed coronary vessels.

Adult↗

[Computerized tomography with single photon emission (SPECT) with technetium-99m MIBI (99mTc-MIBI) in the identification of viable myocardium in patients with chronic ischemic cardiopathy and left ventricular dysfunction].

Resting 99mTc-MIBI cardiac imaging may be poorly accurate in identifying the presence of viable myocardium in patients with chronic coronary artery disease (CAD). In this study, we directly compared the results of resting 99mTc-MIBI SPECT with initial (1 hr) and delayed (5 hrs) images with those of 99mTc-MIBI SPECT after nitroglycerine (NTG) administration in 31 patients with chronic CAD. All patients also underwent rest-redistribution thallium-201 (201Tl) SPECT. In 8 patients, echocardiography was performed before and after coronary revascularization (Rev). Of 682 myocardial segments, 197 showed a marked reduction (< 50% of peak) in MIBI uptake on initial images. MIBI uptake (> or = 10%) was increased in 47 (24%) segments on delayed images (from 43 +/- 8% to 60 +/- 8%, p < 0.001) and in 54 (27%) segments after NTG (from 42 +/- 8% to 60 +/- 8%, p < 0.001). The results of delayed and NTG MIBI images were in agreement in most segments (n = 160, 81%). The results of delayed and NTG MIBI images were in disagreement in the remaining 37 (19%) segments. In particular, 15 segments showed reversible defects on delayed, but not on NTG MIBI images, while 22 on NTG, but not on delayed MIBI images. All the segments with reversible MIBI defects on delayed and/or NTG images were identified as viable on TI-201. In the 8 pts examined before and after Rev. 83% of segments with reversible MIBI defects on delayed images and 87% of those with reversible defects after NTG showed functional recovery after Rev; furthermore, in these patients a significant improvement in global left ventricular function was observed after Rev, as shown by ejection fraction values (from 42 +/- 7% to 47 +/- 7%, p < 0.01). These comparative results show that resting delayed and NTG MIBI imaging provide similar information to identify viable myocardium and to predict functional recovery after coronary Rev in chronic CAD.

Adult↗

Radionuclide monitoring of cardiac adaptations to volume loading in patients with dilated cardiomyopathy and mild heart failure. Effects of angiotensin-converting enzyme inhibition.

BACKGROUND: Cardiac adaptations to volume overload have been poorly investigated in heart failure. The aim of this study was to assess dynamic left ventricular responses to acute volume loading by continuous radionuclide monitoring in patients with asymptomatic to mildly symptomatic left ventricular dysfunction. METHODS AND RESULTS: Left ventricular end-diastolic (EDV) and end-systolic (ESV) volumes, ejection fraction (EF), and peak filling rate (PFR) were monitored by a radionuclide detector (Vest) before and during volume expansion (sodium chloride, 0.9%, 0.25 mL.kg-1.min-1 for 2 hours) in 10 patients with idiopathic dilated cardiomyopathy (DCM) and mild heart failure (New York Heart Association class I or II, ejection fraction < 50%). The patients were studied off treatment and after 6 to 8 weeks of oral treatment with enalapril (5 mg/d). A control group of 11 age- and sex-matched healthy volunteers (N group) was also studied. In the N group, volume loading caused prompt and sustained increases of EDV, EF, and PFR (all P < .001), whereas ESV was progressively reduced (P < .001), and heart rate and blood pressure did not change. In contrast, in DCM, EDV showed a smaller increase than in the N group (two-way ANOVA: F = 5.98, P < .001), ESV increased (P < .001), and EF and PFR remained unchanged. After enalapril, the cardiac adaptations to volume loading were restored to normal. In particular, EDV, EF, and PFR increased (P < .001), and ESV was reduced (P < .001). In 6 additional DCM patients studied before and after 6 to 8 weeks of placebo treatment, left ventricular responses to volume loading remained unchanged. CONCLUSIONS: Left ventricular dynamic adaptations to acute volume loading are compromised in patients with idiopathic DCM and mild heart failure. These impaired responses are ameliorated by treatment with enalapril.

Adult↗

Assessment of systolic wall thickening using technetium-99m methoxyisobutylisonitrile in patients with coronary artery disease: relation to thallium-201 scintigraphy with re-injection.

The results of resting planar ECG-gated technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) imaging were compared with those of thallium-201 (Tl) re-injection after exercise-redistribution scintigraphy in 20 patients (19 men, 1 woman, mean age 53 +/- 10 years) with angiographically proven coronary artery disease. Eight normal subjects (seven men, one woman, mean age 50 +/- 8 years) constituted the control group. In these subjects, only resting 99mTc-MIBI imaging was performed. The standardized percent count increase from end-diastole to end-systole was calculated as an index of wall thickening in 13 segments for each study. Regional wall thickening index (WTI) and 99mTc-MIBI uptake were significantly different (P < 0.05) among segments classified as normal, reversible defects, irreversible defects with increased tracer uptake after re-injection (Re+) or irreversible defects with unchanged tracer uptake after re-injection (Re-) on Tl imaging. Furthermore, WTI and 99mTc-MIBI uptake were significantly higher (P < 0.05) in Re- segments with moderate reduction of Tl uptake (> or = 50% of peak activity) than in Re- segments with severe reduction of Tl uptake (< 50% of peak activity). A significant relationship between WTI and the results of Tl scintigraphy was observed (rho = 0.71, P < 0.0001). The percentage of Re- segments with severe reduction of WTI was significantly higher compared to Re+ segments (64% vs 3%, P < 0.01). Furthermore, compared with moderate Re- segments, a significantly higher percentage of severe Re- segments showed a severe reduction of WTI (86% vs 48%, P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Case-Control Studies↗

Enhanced detection of viable myocardium by technetium-99m-MIBI imaging after nitrate administration in chronic coronary artery disease.

UNLABELLED: The aim of this study was to assess whether nitrate administration improves the imaging capabilities of 99mTc-MIBI tomography in detecting viable myocardium in coronary artery disease (CAD). METHODS: Thirty-one patients with angiographically proven CAD and chronic LV dysfunction (ejection fraction 39% +/- 9%) underwent two 99mTc-MIBI studies on separate days: one under rest conditions and the other after nitroglycerine (0.005 mg/kg per os) administration. Within 1 wk, all patients also underwent rest-redistribution 201Tl imaging. Eight patients were also studied by echocardiography before and 5 +/- 3 mo after coronary revascularization. RESULTS: On resting 99mTc-MIBI images, 302 segments had normal uptake, 183 segments had moderately reduced uptake and 197 had severely reduced uptake. Of the segments with severely reduced uptake, 54 (27%) had increased uptake after nitroglycerine and were viable on 201Tl images. Of the 143 (73%) segments with severely reduced 99mTc-MIBI uptake and no change after nitroglycerine, 81% were nonviable on 201Tl images. In the eight patients studied before and after revascularization, 87% of segments with reversible 99mTc-MIBI defects and abnormal LV function demonstrated functional recovery after revascularization, whereas 89% of segments with irreversible 99mTc-MIBI defects did not. CONCLUSION: In patients with chronic ischemic LV dysfunction, nitrate administration improved the detection of severely hypoperfused but still viable myocardium on 99mTc-MIBI images.

Coronary Circulation↗

[Morpho-functional diagnostic imaging in the assessment of viable myocardium in patients with ischemic heart disease. Correlations between myocardial perfusion and regional function of the left ventricle].

Forty patients (38 men and 2 women, mean age 56 +/- 9 years) with angiographic evidence of coronary artery disease underwent 201Thallium myocardial scintigraphy and two-dimensional echocardiography. 201Thallium uptake and echocardiographic regional ventricular function were studied in corresponding myocardial segments. On exercise-redistribution 201Thallium imaging, 308 segments (51% of the total) had normal Thallium uptake, 48 (8%) exhibited reversible defects and 244 (41%) irreversible defects. Of the latter 244 segments with irreversible defects, 114 (47%) exhibited increased tracer uptake (Re+) and 130 (53%) remained unchanged (Re-) after 201Thallium reinjection at rest. Regional ventricular function was significantly better in the segments with normal Thallium uptake than in the segments with reversible or irreversible defects (p < 0.001). Furthermore, the segments with irreversible defects Re- had impaired regional function compared to the segments with irreversible defects Re+ (p < 0.001). Coronary artery stenosis was significantly more severe in the segments with irreversible defects Re- (93 +/- 16%) than in those with reversible defects (81 +/- 20%) and with irreversible Re+ defects (80 +/- 20%) (both p < 0.001). In conclusion, in coronary artery disease patients, exercise-redistribution 201Thallium cardiac imaging with reinjection at rest can identify severely ischemic but still viable myocardium and may be particularly useful in the prognosis of such patients.

Adult↗

Ambulatory monitoring of left ventricular function during cardiopulmonary exercise tests in normal sedentary subjects.

UNLABELLED: Ambulatory monitoring (VEST) of left ventricular (LV) function is a useful and accurate method to measure cardiac function during exercise and rest. The aim of this study was to evaluate LV response to exercise in normal sedentary subjects. METHODS: Ten normal sedentary subjects underwent continuous ambulatory monitoring of LV function by VEST during upright bicycle exercise associated with combined analysis of pulmonary gas exchange. All parameters of LV function were measured in control conditions at rest, at the anaerobic threshold (point of nonlinear increase in ventilation relative to oxygen uptake) and at peak oxygen uptake (peak VO2). RESULTS: Heart rate and cardiac output significantly increased from control conditions to anaerobic threshold (p < 0.001) and from anaerobic threshold to peak VO2 (p < 0.001). Ejection fraction, end diastolic volume and stroke volume significantly increased from control conditions to anaerobic threshold (p < 0.001), showing no significant change from anaerobic threshold to peak VO2. Finally, end-systolic volume significantly decreased from control conditions to anaerobic threshold (p < 0.001), showing no significant change from anaerobic threshold to peak VO2. CONCLUSION: VEST is particularly useful in the evaluation of cardiac response to exercise in normal sedentary subjects, providing a better understanding of the spectrum of the normal LVEF response to exercise. Our data demonstrate that ejection fraction response to exercise is variable after anaerobic threshold, and a uniform increase is not necessarily expected in normal sedentary subjects.

Adult↗

Technetium-99m-tetrofosmin regional myocardial uptake at rest: relation to severity of coronary artery stenosis in previous myocardial infarction.

UNLABELLED: The aim of this study was to assess the potential role of 99mTc-tetrofosmin cardiac tomography in detecting totally occluded or severely stenosed coronary arteries. METHODS: Thirty-three patients (32 men, 1 woman; mean age, 52 +/- 9 yr) with chronic coronary artery disease (CAD) and left ventricular dysfunction (ejection fraction 40% +/- 12%) underwent resting 99mTc-tetrofosmin SPECT and coronary arteriography within 2 wk. Regional distribution of 99mTc-tetrofosmin activity was compared with the coronary anatomy. Tracer uptake was quantitatively analyzed in 22 segments for each patient. The activity in each segment was expressed as a percent of the peak activity. RESULTS: A significant relationship between the degree of coronary artery stenosis and 99mTc-tetrofosmin uptake was observed (p = -0.64, p < 0.001). Technetium-99m-tetrofosmin uptake was lower (p < 0.001) in segments with 100% coronary occlusion with poor collateral flow (53% +/- 17%) compared to segments supplied by a vessel with 50%-99% coronary stenosis (75% +/- 20%) or a normal noncritically stenosed artery (85% +/- 10%). Furthermore, 99mTc-tetrofosmin uptake was lower (p < 0.01) in segments with 100% coronary occlusion with poor (53% +/- 17%) compared to those with good collateral flow (70% +/- 20%). CONCLUSION: These results demonstrate that quantitative analysis of resting 99mTc-tetrofosmin regional uptake detects the majority of segments supplied by occluded coronary arteries with poor collateral flow and suggest that this tracer may be helpful in the diagnosis of acute myocardial infarction.

Adult↗

[The short- and medium-term ambulatory radionuclide study of left ventricular function (VEST) after aortocoronary bypass].

The aim of the present study was to evaluate the variation in left ventricular function at 15 and 120 days after bypass surgery. Ten male patients (mean age 59.6 +/- 7 years) with previous myocardial infarction and coronary stenosis of at least two main vessels, underwent a radionuclide ambulatory monitoring of left ventricular function (VEST) during: handgrip test, mental stress test, walking, climbing stairs. These tests were carried out 8 +/- 2 days before (T0), 15 +/- 3 days (T1) and 120 +/- 11 days after coronary bypass; heart rate (HR), ejection fraction (EF), stroke volume (SV), and cardiac output (CO) were evaluated beat by beat before and during the test until the maximal HR was reached. Handgrip and mental stress tests did not induce significant variations in cardiac indices both before and after cardiac surgery. No variation in HR was observed before and after the test. During walking, at T0, HR increased from rest to maximal effort (p < 0.01) with a significant decrease in EF (p < 0.05); at T1 HR, EF, SV and CO increased with respect to rest (p < 0.01); AT T2 HR, EF (p < 0.05) and CO (p < 0.01) increased with respect to rest. Climbing stairs, at T0, HR increased (p < 0.01) and EF decreased (p < 0.05); at T1 HR, EF, CO (p < 0.05) and SV (p < 0.01) increased with respect to rest. At T2 an increase in HR (p < 0.01) and CO (p < 0.05) was observed at maximal effort with respect to rest. The statistical analysis on the percentage variations between baseline and maximal effort (climbing stairs) showed a significant increase in SV at T2 compared to T0 (p < 0.01). In conclusion, VEST during daily normal activities 15 days and 4 months after bypass surgery showed a significant increase in cardiac function indices. The best results obtained at T1 can be explained with the transient increase in adrenergic tone at the time of early postoperative period.

Aged↗