Implantable cardioverter-defibrillators and pregnancy: a safe combination?

BACKGROUND: The purpose of this investigation was to evaluate the outcome of pregnancy in women with implantable cardioverter-defibrillators (ICDs). METHODS AND RESULTS: A multicenter retrospective analysis was performed on women with an ICD who became pregnant. Data were collected on 44 patients. The mean age and ejection fraction at the time of the initial ICD implant were 25.6+/-4.9 years and 49.8+/-9.7%, respectively. The mean follow-up after the ICD implant was 4.8+/-2.8 years. Forty-two women had abdominally implanted generators, and 2 had a prepectoral device. Thirty had epicardial lead sensing systems, and 14 had transvenous. Thirty-six (82%) experienced no complications, and 8 (18%) had a medical or device-related complication. The ICD-related problems included tenderness at the ICD pocket scar (2 patients), generator migration (1), and pericarditis secondary to the epicardial patches (1). Medical complications were pulmonary embolism (1), therapeutic abortion (1), worsening hyperthyroidism (1), congestive heart failure (1), and weight loss (1). Thirty-seven women delivered vaginally, and 7 underwent cesarean section. Thirty-nine babies were born healthy, 1 was stillborn, 2 were small for gestational age, 1 had transient hypoglycemia, and 1 woman had a therapeutic abortion unrelated to the ICD. During pregnancy, 33 women received no ICD therapy, 8 had 1 shock, 1 had 5 discharges, 1 had 11 shocks, and 1 had 5 shocks. The total number of shocks during pregnancy ranged from 0 to 11, with an average of 0.66+/-1.9 discharges. Five women had 7 additional pregnancies without an ICD shock. CONCLUSIONS: The mere presence of an ICD should not defer a women from becoming pregnant unless she has an underlying structural cardiac disease that is considered a contraindication. Pregnancy does not increase the risk of major ICD-related complications or result in a high number of ICD discharges.

Adolescent

Defibrillation efficacy of commercially available biphasic impulses in humans. Importance of negative-phase peak voltage.

BACKGROUND: Recent studies have shown that specifically shaped biphasic waveforms can lower energy requirements for ventricular defibrillation. We prospectively compared the defibrillation efficacy of three different biphasic wave shapes incorporated in three commercially available implantable defibrillators. The results led to the development of a second protocol in which the importance of negative-phase peak voltage and duration was investigated. METHODS AND RESULTS: Defibrillation threshold (DFT) testing using different biphasic waveforms was performed randomly on 42 patients undergoing implantation of a cardioverter-defibrillator for ventricular arrhythmias. In 23 patients (group 1), 3 waveforms were tested: a CPI waveform with 60% positive-phase (P1) tilt and 50% negative-phase (P2) tilt, a Medtronic waveform with 65% fixed tilt in both P1 and P2, and a Ventritex waveform with 60% P1 tilt and a P2 leading edge voltage equal to half of the P1 trailing edge voltage. In 19 patients (group 2), 3 biphasic waveforms with equal P1 tilt at 65% but shorter P2 duration or smaller P2 peak voltage were tested. The Endotak C 60 series lead system (CPI) was used in 11 patients in group 1 and 10 patients in group 2. A Transvene lead system (Medtronics) was used in the remaining patients. Stored energy required for defibrillation was significantly lower with the CPI waveform compared with the Ventritex waveform. In group 2, energy requirements were significantly increased for the waveform with a smaller P2 peak voltage, whereas a short P2 duration did not influence defibrillation success. CONCLUSIONS: Our results suggest that specifically shaped biphasic waveforms delivered from commercially available devices can affect energy requirements for defibrillation. More importantly, the amplitude of the P2 peak voltage may be a more critical determinant than the P2 duration for defibrillation success of biphasic waveforms in humans.

Aged

Safety of slow pathway ablation in patients with long PR interval: further evidence of fast and slow pathway interaction.

Whether the presence of abnormal PR before selective slow pathway ablation for AV node reentrant tachycardia increased the risk of complete heart block remains controversial. We report our experience in seven patients with prolonged PR intervals undergoing catheter ablation for AV reentry tachycardia. Their mean age was 66 +/- 12 years; four patients were female and three were male. RF ablation was performed using an anatomically guided stepwise approach. In six patients, common type AV node reentry was induced and uncommon type was observed in the remaining patient. In all seven patients, successful selective slow pathway ablation was associated with no occurrence of complete heart block and was followed by shortening of the AH interval in five patients. In all seven patients, successful ablation was achieved at anterior sites (M1 in two patients and M2 in five patients). Despite AH shortening after ablation, the 1:1 AV conduction was prolonged after elimination of the slow pathway, excluding either sympathetic tone activation or parasympathetic denervation. In conclusion, selective slow pathway ablation can be performed safely in the majority of patients with prolonged PR interval before the procedure. Because successful ablation is achieved at anterior sites in most patients, careful selection and monitoring of catheter position is required.

Aged

Evaluation of the safety and efficacy of deep sedation for electrophysiology procedures administered in the absence of an anesthetist.

UNLABELLED: Several procedures performed in the electrophysiology laboratory (EP lab) require surgical manipulation and are lengthy. Patients undergoing such procedures usually receive general anesthesia or deep sedation administered by an anesthesiologist. In 536 consecutive procedures performed in the EP lab, we assessed the safety and efficacy of deep sedation administered under the direction of an electrophysiologist and in the absence of an anesthetist. Patients were monitored with pulse oximetry, noninvasive blood pressure recordings, and continuous ECGs. The level of consciousness and vital signs were evaluated at 5-minute intervals. Deep sedation was induced in 260 patients using midazolam, phenergan, and meperidine, then maintained with intermittent dosing of meperidine at the following mean doses: midazolam 0.031 +/- 0.024 mg/kg; phenergan 0.314 +/- 0.179 mg/kg; and meperidine 0.391 +/- 0.167 mg/kg per hour. In the remaining 276 patients, deep sedation was induced with midazolam and fentanyl and maintained with a continuous infusion of fentanyl at a mean dose of 2.054 +/- 1.43 micrograms/kg per hour. Fourteen patients experienced a transient reduction in oxygen saturation that was readily reversed following administration of naloxone. An additional 11 patients desaturated secondary to partial airway obstruction, which resolved after repositioning the head and neck. Fourteen patients experienced hypotension with fentanyl. All but one returned to baseline blood pressures following an infusion of normal saline. No patient required intubation and no death occurred. Only three patients had recollection of periprocedure events. No patient remembered experiencing pain with the procedure. Hospital stays were not prolonged as a result of the sedation used. IN CONCLUSION: (1) deep sedation during EP procedures can be administered safely under the guidance of the electrophysiologist without an anesthetist present; (2) the drugs used should be readily reversible in case of respiratory depression; and (3) this approach may reduce the overall cost of the procedures in the EP lab, maintaining adequate patient comfort.

Adjuvants, Anesthesia

Right side implant of the unipolar single lead defibrillation system.

The active can defibrillator has been designed for implantation in the left prepectoral region. Whether this system can be successfully implanted on the right side is unknown. We describe six cases in which placement of the unipolar single lead defibrillation system was successfully attempted in the right prepectoral region due to impediments on the left side. The mean age of the patients was 62 +/- 12 years. Five patients had ischemic heart disease and one idiopathic dilated cardiomyopathy. The endocardial defibrillation electrode was placed in the right ventricle through the right subclavian vein and positioned at the apex in two patients and in the septal position in four patients. Defibrillation threshold testing was performed using a step-up/step-down protocol beginning at 12 J with 3-J increments or decrements. Defibrillation threshold was defined as the lowest energy of the first shock able to terminate ventricular fibrillation. The generator models used were the Medtronic 7218C in 1 patient, the Medtronic 7219C in 3 patients, and the Ventritex Cadet 115 AC in 2 patients. The mean defibrillation threshold was 15 +/- 3 J. The defibrillation thresholds were retested at 1, 3, and 6 months, and showed no significant change in five patients but decreased from 15 J to 12 J in one patient. The presence of impediments on the left side should not preclude attempts to place the unipolar active can system in the right prepectoral region.

Aged

Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers.

Limited information is available regarding potential adverse interactions between transvenous nonthoracotomy cardioverter defibrillators and pacemakers. We describe our experience with 37 patients who have undergone successful implantation of both a transvenous defibrillator and pacemaker. The patients' mean age was 64 +/- 12.9 years. Thirty-three were male and four were female. The mean LVEF was 30.8% +/- 11.8%. The indications for pacemaker implantation included sick sinus syndrome in 13 patients, complete heart block in 15 patients, sinus bradycardia secondary to medications in 8 patients, and neurocardiogenic syncope in 1 patient. The indications for insertion of a defibrillator included medically refractory VT in 27 patients and sudden cardiac death in 10 patients. Twenty-three patients received an Endotak lead and 14 patients received a Transvene lead. Eighteen patients had a pacemaker prior to an ICD, 14 patients had an ICD prior to a pacemaker, and 4 patients had both devices placed simultaneously. Interaction was evaluated at implant of the second device and 1-3 days after both devices were placed. Detection of VF/VT was analyzed during asynchronous pacing (DOO/VOO) with maximum pacing output. In addition, in six patients, DFT was determined before and after pacemaker implantation. In 14 patients (38%), device interactions that could not always be optimally corrected were observed. In five patients, the pacemaker was reset to the "noise reversion" mode after high energy ICD discharge. Oversensing of atrial pacemaker stimuli resulted in inappropriate ICD firings in four patients. This was observed only with a specific device and could not be prevented by atrial lead repositioning in two of them, but required reprogramming of the pacemaker to the VVI mode. An increase in DFT was observed in five patients who had a pacemaker implanted after an ICD. Compared with previously published studies, a greater frequency of transvenous ICD and pacemaker interactions were observed. Considering that almost 50% of the patients already have a pacemaker at the time of ICD implant, the availability of defibrillators with dual chamber pacing capability will not eliminate the potential for this problem.

Aged

Ventricular tachycardia: pathophysiology and radiofrequency catheter ablation.

Limitations of pharmacological therapy for VT have led to great interest in alternative nonpharmacological therapies. The appeal of a curative therapy for VT initially led to the search for operative techniques to identify and destroy the underlying substrate, and more recently, has resulted in the development of catheter techniques to achieve the same goal in the electrophysiology laboratory. Investigations into the pathophysiology of VT have resulted in the recognition that this arrhythmia reflects a mechanistically and anatomically heterogeneous set of disorders. Recent growth in our understanding of these distinctions has both led to, and resulted from, simultaneous advances in catheter ablation techniques. The clinical electrophysiology laboratory has served as a testing ground for theories derived from in vitro and animal experiments while also providing its own set of human experimental data regarding the pathophysiology and treatment of VT. As a result of this process, several distinct forms of VT that are amenable to catheter ablation have been characterized. This article will summarize current knowledge of the pathophysiology of various VT subtypes and of techniques for catheter mapping and ablation.

Arrhythmias, Cardiac

Opposite feedback control of renin and aldosterone biosynthesis in the adrenal cortex by angiotensin II AT1-subtype receptors.

The aims of this study were to identify whether tissue renin is regulated by a negative-feedback mechanism produced by locally generated angiotensin (Ang II) in the adrenal cortex and to detect the pathway of Ang II modulation. For this purpose, in 36 12-week old, salt-restricted, nephrectomized Sprague-Dawley rats, we studied the effects of the Ang II AT1-subtype receptor antagonist losartan and of the Ang II AT2-subtype receptor antagonist PD123319 on renin mRNA and activity, aldosterone synthase mRNA, and AT1a-, AT1b-, and AT2-subtype receptor expression in the adrenal cortex. Ten additional rats, kept on a regular diet and then nephrectomized, were also studied. In salt-restricted, nephrectomized rats, losartan administration caused increases of adrenal renin mRNA (P<.05) and activity (P<.05) and a concomitant reduction of aldosterone synthase mRNA (P<.05). In addition, after losartan AT1b, receptor mRNA was reduced (P<.05), AT1a receptor mRNA was unchanged, and AT2 mRNA was increased (P<.05). PD123319 did not significantly modify any of these parameters. In conclusion, in salt-restricted, nephrectomized rats, selective antagonism of AT1-subtype receptors stimulates the expression and the activity of renin in the adrenal cortex. This observation demonstrates that Ang II locally formed in the adrenal cortex exerts a modulatory negative-feedback action on adrenal renin biosynthesis independent of the influence of the circulating renin-Ang system; this action is largely mediated through the AT1b-subtype receptors.

Adrenal Cortex

Impact on ventricular function and quality of life of transcatheter ablation of the atrioventricular junction in chronic atrial fibrillation with a normal ventricular response.

We assessed left ventricular function and quality of life after atrioventricular junction ablation and pacemaker implant in 14 patients with chronic atrial fibrillation and normal ventricular response. A significant improvement in left ventricular ejection fraction, fractional shortening, and functional capacity were observed at follow-up, suggesting that in patients with chronic atrial fibrillation a regular heart beat may be preferable over rate control.

Aged

Evaluation of the effect of transthoracic cardioversion from ventricular tachycardia to sinus rhythm on left atrial mechanical function.

We measured left atrial function during sinus rhythm before and after ventricular tachycardia was induced in an electrophysiology laboratory, using peak transmitral A-wave velocity from pulsed-Doppler transthoracic echocardiography as a marker of left atrial mechanical function. The results of this prospective study do not support the hypothesis that a transthoracic shock of mild to moderate energy diminishes atrial mechanical function.

Adolescent

Incidence and clinical relevance of the occurrence of bundle-branch block in patients treated with thrombolytic therapy.

BACKGROUND: Whether thrombolytic therapy alters the incidence and clinical outcome of bundle-branch block is unclear. METHODS AND RESULTS: We examined the occurrence of new-onset bundle-branch block, both transient and persistent, in 681 patients with acute myocardial infarction enrolled in the Thrombolysis and Angioplasty in Myocardial Infarction 9 and Global Utilization of Streptokinase and t-PA for Occluded Arteries 1 protocols. Each patient underwent continuous 12-lead ECG monitoring for 36 to 72 hours with the Mortara ST monitoring system. Bundle-branch block was characterized as right, left, alternating, transient, or persistent. The overall incidence of bundle-branch block was 23.6% (n = 161), with transient block in 18.4% (n = 125) and persistent block in 5.3% (n = 36). Right bundle-branch block was found in 13% (n = 89) of the population; left bundle-branch block was found in 7% (n = 48). Alternating bundle-branch block was seen in 3.5% (n = 24) of patients. Left anterior descending artery infarcts accounted for most bundles (54%, n = 79). Patients with bundle-branch block had lower ejection fractions, higher peak creatine phosphokinase levels (P < .0001), and more diseased vessels (P < .019). Mortality rates in patients with and without bundle-branch block were 8.7% and 3.5%, respectively (P < .007). A higher mortality rate was observed in the presence of persistent (19.4%) versus transient (5.6%) or no (3.5%) bundle-branch block (P < .001). CONCLUSIONS: Thrombolytic therapy reduces the overall mortality rate associated with persistent bundle-branch block. However, persistent bundle-branch block remains predictive of a higher mortality rate than either transient or no bundle-branch block. Continuous 12-lead ECG monitoring provides an accurate characterization of the incidence and type of conduction disturbances after acute myocardial infarction.

Aged

Recurrence of neurocardiogenic syncope without pharmacologic interventions.

In 54 patients with positive tilt and who refused medical therapy, we observed a significant decrease in the frequency of syncopal spells after diagnosis and counseling. However, symptoms were reported at follow-up by 64.8% of the patients and were predicted by the frequency and total number of syncope episodes before upright tilt.

Adult

Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators. Prospective comparison of different lead system-device combinations.

BACKGROUND: The purpose of this study was to prospectively analyze redetection problems after unsuccessful shock with different lead systems and devices. METHODS AND RESULTS: We prospectively analyzed detection and redetection characteristics among transvenous implantable cardioverter-defibrillators (ICDs) using standard bipolar and integrated bipolar sensing. Monophasic and biphasic ICDs were included. Subthreshold shocks were intentionally delivered, and redetection of ventricular fibrillation (VF) was assessed before discharge and at 1, 3, 6, and 12 months later. Sensing of VF resulting from antitachycardia pacing and low-energy cardioversion ( < or = 2 J) also was analyzed. Before inclusion in the study, each patient underwent subthreshold shock testing at three different time intervals. Among the 160 ICDs with standard bipolar sensing, 530 VF inductions were analyzed. After the failed shocks, undersensing was more frequent (3% versus 20%, P<.01) but did not remarkably prolong redetection (3.1 +/- 0.8 versus 3.3 +/- 1.1 seconds). Among the 201 ICDs with integrated bipolar sensing, 80 were connected to a CPI device (60 Ventak 1600-Endotak 60 series and 20 PRx II 1715-Endotak 70 series) and 121 to the Ventritex defibrillator (91 Endotak 60 series, 14 TVL systems, and 16 Endotak 70 series). After 252 failed shocks, redetection was prolonged with the CPI system (3.1 +/- 1.4 versus 4.6 +/- 3.6 seconds, P<.05) but did not change after 396 failed shocks with the Ventritex ICD (5.4 +/- 1.9 versus 4.9 +/- 2.2 seconds). This may reflect different nominal settings for detection and redetection. In 9 of 121 patients with Ventritex and 1 of 80 with the CPI ICDs, the devices failed to redetect VF. However, redetection malfunction was never observed in patients with integrated bipolar systems with >6-mm electrode separation. After antitachycardia pacing in 1 patient and a 2-J shock in 1 patient, ventricular tachycardia turned into VF, which was undetected. Both patients used the Endotak 60 series-Cadence combination. None of the patients showing VF undersensing had sudden death at follow-up. Only 3 of the 12 patients with sensing malfunction were on antiarrhythmia drugs at the time of testing. Analysis of endocardial electrograms showed that failure to redetect VF is not associated with a uniform reduction but with a rapid and repetitive change of electrogram amplitude. CONCLUSIONS: Standard bipolar sensing redetects VF more effectively than integrated bipolar sensing. Endocardial electrogram analysis provides insights into the understanding of the mechanism of undersensing, and certain lead-device combinations result in a higher occurrence of VF undersensing. The clinical relevance of this phenomenon remains unknown.

Adult

Testing different biphasic waveforms and capacitances: effect on atrial defibrillation threshold and pain perception.

OBJECTIVES: The goal of this study was to compare the effect of different tilts and capacitances for biphasic shocks on atrial defibrillation efficacy and pain threshold. BACKGROUND: Although biphasic shocks have been shown to be superior to monophasic shocks, the effect of tilt and capacitance on atrial defibrillation success and pain perception has not been studied in patients. METHODS: Atrial defibrillation threshold (DFT) testing was performed using a right atrial appendage/coronary sinus lead configuration in 38 patients with a history of paroxysmal atrial fibrillation undergoing an invasive electrophysiologic study. Biphasic waveforms with 40%, 50%, 65%, 80%, 30%/50% and 40%/50% were tested randomly in 22 patients (Group 1). In 16 patients (Group 2), a 65% tilt waveform with 50- and 120-microF capacitance was tested. Before sedation, pain sensation was graded by 15 patients in Group 1 after delivery of a 0.5-J shock and by 10 patients in Group 2 after two 1.5-J shocks with 50- and 120-microF capacitance were delivered. RESULTS: The DFT energy for the 50% tilt waveform was significantly lower than the 65%, 80% and 30%/50% tilt waveforms. The 40%/50% tilt waveform provided slightly lower energy requirements than the 50% tilt waveform. Nine patients (60%) described the 0.5-J shock as very painful, and four (26.6%) complained of slight pain. The 50-microF capacitor lowered energy requirements compared with the 120-microF capacitor. Six patients (60%) perceived the 1.5-J 50-microF capacitor shock as more painful, whereas three (30%) perceived both shocks as equally painful. CONCLUSIONS: Biphasic waveforms with 50% tilt in both phases and a smaller tilt in the positive phase than that in the negative phase (40%/50%) provided a decrease in energy requirements at atrial DFT. In addition, stored energy was reduced by biphasic shocks with 50-microF capacitance compared with 120-microF capacitance. Despite the reduction in energy requirements, shocks < 1 J continued to be perceived as painful in the majority of patients.

Aged

Impact of defibrillator-can size on defibrillation success with a single-lead unipolar system.

In a study of 11 dogs, we assessed whether the defibrillation energy requirements of a single transvenous right ventricular electrode/defibrillator can system depended on the can size. We compared the defibrillation threshold obtained with 65% fixed-tilt biphasic shocks with 20, 40, and 80 ml surface area defibrillator cans. The energy was delivered between a right ventricular coil inserted through the jugular vein and the can placed in the subcutaneous tissue of the left superior chest wall. The testing order of each can size was randomly determined. Triplicate defibrillation thresholds were obtained with each can. Despite a higher impedance (20 ml 85 +/- 22 ohms vs 80 ml 71 +/- 16 ohms, p < 0.01), the 20 ml can resulted in a similar defibrillation threshold compared with the 80 ml (20 ml 7.6 +/- 2.8 J vs 80 ml 7.5 +/- 3.4 J) and the 40 ml cans (20 ml 7.6 +/- 2.8 J vs 7.5 +/- 3.4 J). In conclusion, with the unipolar lead system the can size does not appear to be a factor limiting defibrillation success. Even a can the size of a pacemaker does not appear to significantly affect the defibrillation efficacy of this lead system.

Animals

Bicervical uterus and septate vagina: report of a previously undescribed Müllerian anomaly.

A case of non-septate uterus with double cervix and complete longitudinally septate vagina is described. This previously undescribed Müllerian anomaly has been detected by complete clinical and instrumental investigations (transvaginal ultrasonography, urography, hysterosalpingography, hysteroscopy and laparoscopy). Aetiological hypotheses are discussed and we suggest adding the uterovaginal malformation described in this report to the embryological classification recently proposed by Acien et al. (1991, 1992) which postulates isolated Müllerian anomalies as a consequence of a minor mesonephric defect.

Adult