PubMed HealthSearch

Biomedical subjects

A Nicosia

Publications and source records attributed to A Nicosia.

At least 19 recordsLinked to original sources

Bacteriophage lambda display of complex cDNA libraries: a new approach to functional genomics.

We describe the construction and characterization of two lambda surface displayed cDNA expression libraries derived from human brain and mouse embryo. cDNA inserts were obtained by tagged random-priming elongation of commercially available cDNA libraries and cloned into a novel lambda vector at the 3' end of the D capsid protein gene, which produced highly complex repertoires (1x10(8) and 2x10(7) phage). These libraries were affinity selected with a monoclonal antibody against the neural specific factor GAP-43 and with polyclonal antibodies that recognize the EMX1 and EMX2 homeoproteins. In both cases rapid identification of specific clones was achieved, which demonstrates the great potential of the lambda display system for generating affinity selectable cDNA libraries from complex genomes.

Amino Acid Sequence

Hypervariable region 1 variants act as TCR antagonists for hepatitis C virus-specific CD4+ T cells.

In various human viral infections, the appearance of mutated epitopes displaying TCR antagonistic activity has been correlated with the severity and persistence of infection. In hepatitis C virus (HCV) infection, where the virus persistence has been associated with the rapid and substantial Ag modifications occurring during replication, TCR antagonism has been evidenced in CD8+ T cell responses. However, CD4+ T cell antagonism may be another important strategy by which HCV eludes a protective response, because sustained Th responses directed against several HCV Ags are associated with a self-limited course of infection. The data reported here represent the first evidence that variants of the hypervariable region (HVR1) of the putative Envelope 2 protein of HCV can act as powerful TCR antagonists for HVR1-specific CD4+ T cells isolated from HCV-infected individuals. Using classical antagonism assays, we observed strong inhibition of cellular proliferation and cytokine production when the agonist and the antagonist ligands were simultaneously presented by the same APCs. The presence in HVR1 of conserved residues, critical for binding to HLA-DR molecules, supports the function of HVR1 variants as TCR antagonists. In conclusion, our data evidence an antagonism phenomenon, which was achieved by naturally occurring class II-restricted T cell epitopes whose mechanism was addressed in terms of the antagonist capacity to inhibit agonist-mediated TCR down-regulation and early signal transduction.

Amino Acid Sequence

A randomized comparison of trapidil (triazolopyrimidine), a platelet-derived growth factor antagonist, versus aspirin in prevention of angiographic restenosis after coronary artery Palmaz-Schatz stent implantation.

The aim of the study is to assess the safety of trapidil in the setting of coronary stenting and to evaluate its efficacy in reducing angiographic in-stent restenosis. One hundred eighteen patients undergoing Palmaz-Schatz stent implantation were randomly assigned to receive antiplatelet therapy using either aspirin (325 mg/d) or trapidil (400 mg/d), in combination with ticlopidine (500 mg) for the first month. At entry, both groups were comparable with regard to clinical, angiographic, and procedural characteristics. At 6-month angiographic follow-up, >50% restenosis occurred in 15 of 52 lesions (28.8%) of the aspirin group and in 14 of 47 lesions (29.8%) of the trapidil group (P=not significant, NS). At 6-month clinical follow-up, there was no difference in the two groups in the rate of adverse events (2.0% vs. 2.1%, P=NS), medication side effects (4.0% vs. 4.2%, P=NS), and peripheral vascular complications (4.0% vs. 4.2%, P=NS). In conclusion, treatment with trapidil seems to be associated with a similar incidence of stent restenosis and adverse cardiac events as compared to aspirin and could be a valuable alternative to aspirin in the setting of coronary stenting.

Aged

Antibody responses to hepatitis C virus hypervariable region 1: evidence for cross-reactivity and immune-mediated sequence variation.

Sequence heterogeneity of hepatitis C virus (HCV) is unevenly distributed along the genome, and maximal variation is confined to a short sequence of the HCV second envelope glycoprotein (E2), designated hypervariable region 1 (HVR1), whose biological function is still undefined. We prospectively studied serological responses to synthetic oligopeptides derived from HVR1 sequences of patients with acute and chronic HCV infection obtained at baseline and after a defined follow-up period. Extensive serological cross-reactivity for unrelated HVR1 peptides was observed in the majority of the patients. Antibody response was restricted to the IgG1 isotype and was focused on the carboxyterminal end of the HVR1 region. Cross-reactive antibodies could be readily elicited following immunization of mice with multiple antigenic peptides carrying HVR1 sequences derived from our patients. The vigor and heterogeneity of cross-reactive antibody responses were significantly higher in patients with chronic hepatitis compared with those with acute hepatitis and in patients infected with HCV type 2 compared with patients infected with other viral genotypes (predominantly type 1), which suggest that higher time-related HVR1 sequence diversification previously described for type 2 may result from immune selection. The finding of a statistically significant correlation between HVR1 sequence variation, and intensity, and cross-reactivity of humoral immune responses provided stronger evidence in support of the contention that HCV variant selection is driven by the host's immune pressure.

Adolescent

Usefulness of platelet glycoprotein IIb/IIIa inhibitors in coronary stenting for reconstruction of complex lesions: procedural and 30 day outcome.

BACKGROUND: Intracoronary stent implantation during percutaneous transluminal coronary angioplasty (PTCA) has shown favorable results, reducing acute complications associated with PTCA, such as coronary artery dissection and abrupt or threatened vessel closure. However, treatment of lesions with a complex morphology and diffuse disease, requiring long or multiple coronary stents, is still associated with a poorer outcome. We investigated the hypothesis that abciximab might lead to a different outcome in patients with complex coronary lesions, which require long or multiple stent implantation. METHODS: One hundred and six patients were randomized to receive either a combination of abciximab (bolus and 12 hour infusion) and weight-adjusted low-dose heparin or weight-adjusted heparin alone and followed up to 30 days. RESULTS: The procedural success rate was 100% in both groups of patients. In the control group a composite rate of major adverse events such as any death irrespective of cause, Q wave or non-Q wave myocardial infarction, acute or subacute stent thrombosis and urgent revascularization of 15.3% was shown at 30-day follow-up. The use of abciximab reduced the composite adverse event rate to 3.7% (76% absolute reduction, p < 0.05). CONCLUSIONS: The use of abciximab during high risk stenting is safe and reduces the risk of cardiac events at 30-day follow-up as compared to standard treatment with heparin. A longer follow-up period is warranted to confirm the beneficial effects observed at 30 days with abciximab in this setting.

Abciximab

Efficient display of an HCV cDNA expression library as C-terminal fusion to the capsid protein D of bacteriophage lambda.

We describe the construction and characterization of a hepatitis C virus (HCV) cDNA expression library displayed as a fusion to the carboxy terminus of the capsid protein D of bacteriophage lambda. cDNA inserts were obtained by tagged random-priming of the HCV genome and cloned into a lambda vector from which chimeric phage bearing both wild-type D protein and D fusion products on the capsid surface were produced. The resulting library was affinity-selected with anti-HCV human monoclonal antibodies recognizing linear or conformational epitopes, and human sera from HCV-infected patients. Selection was monitored by immuno-screening experiments, ELISA, and sequence analysis of positive clones. The performance of this library was compared with two additional HCV cDNA display libraries generated as N-terminal fusions to the III and VIII capsid proteins of filamentous phage M13. The results obtained demonstrate the great potential of the lambda display system for constructing complex cDNA libraries for natural ligand discovery.

Antibodies, Monoclonal

Towards a solution for hepatitis C virus hypervariability: mimotopes of the hypervariable region 1 can induce antibodies cross-reacting with a large number of viral variants.

The hypervariable region 1 (HVR1) of the putative envelope protein E2 of hepatitis C virus (HCV) is the most variable antigenic fragment in the whole viral genome and is mainly responsible for the large inter-and intra-individual heterogeneity of the infecting virus. It contains a principal neutralization epitope and has been proposed as the major player in the mechanism of escape from host immune response. Since anti-HVR1 antibodies are the only species shown to possess protective activity up to date, developing an effective prevention therapy is a very difficult task. We have approached the problem of HVR1 variability by deriving a consensus profile from >200 HVR1 sequences from different viral isolates and used it as a template to generate a vast repertoire of synthetic HVR1 surrogates displayed on M13 bacteriophage. This library was affinity selected using many different sera from infected patients. Phages were identified which react very frequently with patients' sera and bind serum antibodies that cross-react with a large panel of HVR1 peptides derived from natural HCV variants. When injected into experimental animals, the 'mimotopes' with the highest cross-reactivity induced antibodies which recognized the same panel of natural HVR1 variants. In these mimotopes we identified a sequence pattern responsible for the observed cross-reactivity. These data may hold the key for future development of a prophylactic vaccine against HCV.

Amino Acid Sequence

Identification of peptides binding to IgG in the CSF of multiple sclerosis patients.

Phage displayed random peptide libraries were screened in order to identify phagotopes reacting with the IgG present in the cerebrospinal fluid (CSF) of multiple sclerosis (MS) patients. Six families of phagotopes each composed of different isolates were identified. These phagotopes were used as reagents, to characterise IgG present in the CSF of MS patients. The following results were obtained: (a) CSF antibodies from different patients display different specificities; (b) anti-phagotope antibodies are also present in the serum of MS patients; (c) Anti-phagotope antibodies are equally frequent in the serum of MS patients and of healthy individuals; (d) some of the anti-phagotope antibodies are enriched in the CSF of MS patients. These data show that the natural antigen(s) recognised by CSF antibodies is rather common in the general population. By using the selected phagotopes as immunogens in rabbits, we have derived large quantities of anti-phagotope antisera which can provide for useful tools toward the identification of the natural antigen(s) recognised by MS CSF antibodies.

Adult

CSF-enriched antibodies do not share specificities among MS patients.

The specificity of the oligoclonal immunoglobulins found in MS CSF is unknown. We have previously shown that random peptide libraries displayed on phage can be used to identify specific ligands for CSF antibodies. Here we describe the use of this tool in the attempt to identify MS-specific CSF-enriched antibody reactivities with potential pathogenic, diagnostic or prognostic value. Applying different experimental strategies, several ligands reacting with CSF-enriched antibodies were identified. When tested against a panel of 55 MS patients, none of the ligands found were recognized by antibodies shared by any two patients. We used the selected peptides to demonstrate the stability in time of CSF-enriched antibodies notwithstanding disease progression.

Adult

[Dissolution of acute stent thrombosis by abciximab bolus].

Abciximab, REOPRO, a potent inhibitor of platelet aggregation via glycoprotein IIb/IIIa inhibition, has shown to be effective in the prevention of short and long-term complications of percutaneous coronary interventions. Very few reports on the role of this drug in the setting of acute stent thrombosis have been published. We report 1 case of the effectiveness of REOPRO in the complete lysis of stent thrombus with reperfusion of the coronary vessel and its collaterals. This case suggests an important role of platelets in the setting of acute stent thrombosis and a thrombolytic effect of REOPRO.

Abciximab

[Safety, feasibility and efficacy of a new single-wire stent in the treatment of complex coronary lesions: the angiostent].

The angiostent is a single wire, flexible, highly radiopaque, balloon expandable stent. To evaluate the feasibility and safety of the deployment of this new stent, we report the clinical and procedural results of 70 procedures performed in 51 native coronary arteries of 48 patients, with objective evidence of ischemia. The target lesion was located in the left anterior descending artery in 18 (36%) cases, in the circumflex artery in 16 (31%) cases and in the right coronary artery in 17 (33%) cases. Mean reference vessel diameter was 3.2 +/- 0.4 mm and the minimal luminal diameter was 0.4 +/- 0.3 mm, with a mean diameter stenosis of 86 +/- 10%. Type B2 and C lesions were encountered in 56% of the cases. More than one angiostent was implanted in 14 vessels and multiple stenting was accomplished with the use of different stents in 8 coronary arteries. No major complications were reported. The post-procedural minimal luminal diameter was 3.2 +/- 0.4 mm with a mean diameter stenosis of 1.4 +/- 3.7%. In 25 cases (49%) major side branches raised from the stented segment and in all but one remained patent. In conclusion, the implantation of the angiostent is safe, feasible and effective, as it can be easily deployed at the lesion site, used for the treatment of complex lesions and preserves the patency of jailed side-branches.

Anticoagulants

[Endothelin-1 variation in the coronary circulation during angioplasty with a stent implant].

Endothelin-1 (ET-1) is an endothelium-derived mediator with vasoconstrictive and mitogenic activity which stimulates vascular smooth muscle cell proliferation. The aim of this study was to evaluate ET-1 production during percutaneous transluminal coronary angioplasty (PTCA) and elective stent implantation. We hypothesized that the additional vessel wall trauma induced by stent deployment might be associated with a greater production of ET-1. To this end, ET-1 levels were measured in 18 patients undergoing PTCA and stenting (12 with left anterior descending coronary artery stenosis and 6 with circumflex artery lesion). The sampling sites were the coronary ostium and coronary sinus in basal conditions (before the procedure), during first balloon inflation, and 5, 20, 60 min after the end of first balloon inflation. At baseline, ET-1 levels were higher in the coronary sinus than in coronary ostium (1.58 +/- 0.22 vs 1.29 +/- 0.20 pg/ml, p < 0.001). During first balloon inflation, ET-1 coronary sinus levels significantly diminished with respect to the basal levels (1.08 +/- 0.32 vs 1.58 +/- 0.22 pg/ml, p < 0.001). Further significant variations of ET-1 levels were not detected neither following the first balloon inflation nor after stent deployment. In conclusion, the culprit lesion seems to produce most of ET-1 circulating in the coronary tree. This is demonstrated by higher ET-1 levels in the coronary sinus compared to coronary ostium at baseline, and even more by the significant ET-1 reduction in the coronary sinus during first balloon inflation. Despite our expectations, we did not detect any significant ET-1 increase during stent deployment.

Aged

ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans.

BACKGROUND: Automated systems for the quantitative analysis of three-dimensional (3D) sets of intravascular ultrasound (IVUS) images have been developed to reduce the time required to perform volumetric analyses; however, 3D image reconstruction by these nongated systems is frequently hampered by cyclic artifacts. METHODS AND RESULTS: We used an ECG-gated 3D IVUS image acquisition workstation and a dedicated pullback device in atherosclerotic coronary segments of 30 patients to evaluate (1) the feasibility of this approach of image acquisition, (2) the reproducibility of an automated contour detection algorithm in measuring lumen, external elastic membrane, and plaque+media cross-sectional areas (CSAs) and volumes and the cross-sectional and volumetric plaque+media burden, and (3) the agreement between the automated area measurements and the results of manual tracing. The gated image acquisition took 3.9+/-1.5 minutes. The length of the segments analyzed was 9.6 to 40.0 mm, with 2.3+/-1.5 side branches per segment. The minimum lumen CSA measured 6.4+/-1.7 mm2, and the maximum and average CSA plaque+media burden measured 60.5+/-10.2% and 46.5+/-9.9%, respectively. The automated contour-detection required 34.3+/-7.3 minutes per segment. The differences between these measurements and manual tracing did not exceed 1.6% (SD<6.8%). Intraobserver and interobserver differences in area measurements (n=3421; r=.97 to.99) were <1.6% (SD<7.2%); intraobserver and interobserver differences in volumetric measurements (n=30; r=.99) were <0.4% (SD<3.2%). CONCLUSIONS: ECG-gated acquisition of 3D IVUS image sets is feasible and permits the application of automated contour detection to provide reproducible measurements of the lumen and atherosclerotic plaque CSA and volume in a relatively short analysis time.

Adult

Is intravascular ultrasound after coronary stenting a safe procedure? Three cases of stent damage attributable to ICUS in a tantalum coil stent.

The use of coronary stents decreases the morbidity associated with acute closure and restenosis after balloon angioplasty. Intracoronary ultrasound (ICUS) guidance of stent implantation has been advocated to improve stent deployment and thereby to further improve the clinical outcome after stenting, over and above balloon angioplasty. Whereas the merits of intracoronary ultrasound in this respect still remain to be proven, the present paper illustrates that ICUS itself may also entail complications. This paper reports on three cases of stent damage induced or aggravated by the ICUS procedure.

Aged

Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification.

OBJECTIVE: This study evaluates the feasibility, reliability and reproducibility of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) image acquisition during automated transducer withdrawal and automated three-dimensional (3D) boundary detection for assessing on-line the result of coronary stenting. BACKGROUND: Systolic-diastolic image artifacts frequently limit the clinical applicability of such automated analysis systems. METHODS: In 30 patients, after successful angiography-guided implantation of 34 stents in 30 target lesions, we carried out IVUS examinations on-line with the use of ECG-gated automated 3D analyses and conventional manual analyses of two-dimensional images from continuous pullbacks. These on-line measurements were compared with off-line 3D reanalyses. The adequacy of stent deployment was determined by using ultrasound criteria for stent apposition, symmetry and expansion. RESULTS: Gated image acquisition was successfully performed in all patients to allow on-line 3D analysis within 8.7 +/- 0.6 min (mean +/- SD). Measurements by on-line and off-line 3D analyses correlated closely (r > or = 0.95), and the minimal stent lumen differed only minimally (8.6 +/- 2.8 mm2 vs. 8.5 +/- 2.8 mm2, p = NS). The conventional analysis significantly overestimated the minimal stent lumen (9.0 +/- 2.7 mm2, p < 0.005) in comparison with results of both 3D analyses. Fourteen stents (41%) failed to meet the criteria by both 3D analyses, all of these not reaching optimal expansion, but only 7 (21%) were detected by conventional analysis (p < 0.02). Intraobserver and interobserver comparison of stent lumen measurements by the automated approach revealed minimal differences (0.0 +/- 0.2 mm2 and 0.0 +/- 0.3 mm2) and excellent correlations (r = 0.99 and 0.98, respectively). CONCLUSIONS: ECG-gated image acquisition after coronary stent deployment is feasible, permits on-line automated 3D reconstruction and analysis and provides reliable and reproducible measurements; these factors facilitate detection of the minimal lumen site.

Coronary Angiography

Simpson's rule for the volumetric ultrasound assessment of atherosclerotic coronary arteries: a study with ECG-gated three-dimensional intravascular ultrasound.

BACKGROUND: Volumetric intravascular ultrasound (IVUS) assessment provides complementary information on atherosclerotic plaques. The volumes can be calculated by applying Simpson's rule to cross-sectional area data of multiple IVUS images, acquired with a fixed sample spacing, which is the distance (along the vessel's axis) between two images. OBJECTIVE: To evaluate the effect of different sample spacings on the results of volumetric IVUS measurements. METHODS: A stepwise electrocardiographically gated IVUS image-acquisition and automated three-dimensional analysis approach was applied to 26 patients. Twenty-eight coronary segments with mild-to-moderate coronary atherosclerosis were examined. Volumetric measurements of five images per mm (i.e. sample spacing 0.2 mm), representing a complete scanning of the coronary segment, were considered the optimal standard, against which volumetric measurements of three, one, and one-half images per mm (i.e. larger sample spacings) were compared. RESULTS: The lumen, total vessel, and plaque volumes obtained with five images per mm were 183.3 +/- 2.8, 350.6 +/- 141.6, and 167.3 +/- 89.2 mm3. There was an excellent correlation (r = 0.99, P < 0.001) between these data and volumetric measurements with larger sample spacings. The volumetric measurements with larger sample spacings differed on average only by a little (< 0.7%) from the optimal standard measurements. However, a relatively small, but significant, increase in SD of these differences was associated with the wider sample spacings (< 3.6%, P < 0.05). CONCLUSIONS: The width of the sample spacing has a relatively small but significant impact on the variability of volumetric intravascular ultrasound measurements. This should be considered when designing future volumetric studies. The electrocardiographically gated acquisition of five IVUS images per mm axial length during a stepwise transducer pull-back is an ideal approach, particularly when addressing with IVUS volumetric changes that are assumed small, such as those expected in studies of the progression and regression of atherosclerosis.

Coronary Artery Disease