PubMed Health⌕ Search

Biomedical subjects

A Nilgun Ozturk

Publications and source records attributed to A Nilgun Ozturk.

6 recordsLinked to original sources

Bond strength between root dentin and three glass-fiber post systems.

STATEMENT OF PROBLEM: Glass-fiber posts were introduced for use after endodontic therapy instead of metal alloy and ceramic posts. There are several new types of glass-fiber post systems available, but little is known about how well these posts bond to the root surface. PURPOSE: The purpose of this in vitro study was to compare the bond strengths of 3 different types of glass-fiber post systems-opaque, translucent, and electrical glass-in 3 different locations of prepared post spaces. MATERIAL AND METHODS: Sixty human intact single-rooted extracted teeth were used. The root canals were prepared using a step-back technique and obturated with gutta-percha using lateral condensation. The roots were divided into 3 experimental groups and further divided into 2 subgroups according to testing time (n=10). Roots were restored with 1 of the following post systems according to the manufacturer's instructions: opaque glass-fiber posts (Snowpost), translucent glass-fiber posts (FiberMaster), and electrical glass-fiber posts (Everstick). A self-etching primer (Clearfil Liner Bond) was applied to the walls of the post spaces, allowed to etch for 30 seconds, and gently air dried. A dual-polymerized bonding agent (Clearfil Liner Bond, Bond A and B) was then applied to the same walls. A dual-polymerizing resin luting agent (Panavia F) was mixed for 20 seconds and then placed in the post spaces using a lentulo spiral instrument. The roots were placed in light-protected cylinders; then the light source was placed directly on the flat cervical tooth surfaces and the cement was polymerized. Specimens were stored in light-proof boxes for 24 hours or 1 week after the polymerization procedure. Each root was cut horizontally, and six 1-mm-thick root segments (2 apical, 2 middle, and 2 cervical) were prepared. Using a push-out test, the bond strength between post and dentin was measured after 24 hours or 1 week using a universal testing machine. Statistical analysis was performed with 3-way ANOVA followed by independent t tests (alpha=.05) to detect differences between groups defined by the specific interacting variables. The different combinations of posts and luting material from the cervical segments were analyzed with SEM. RESULTS: The 3-way ANOVA indicated that push-out test values varied significantly according to the post system used (opaque, electrical, and translucent) (P<.01); the root segments (cervical, middle, and apical) (P<.01), however, did not vary statistically according to the time of testing (24 hours and 1 week). Opaque and electrical glass-fiber posts showed higher bond strength values than translucent posts (P<.01). Push-out bond strength values of cervical segments were significantly higher than the middle and apical segments in translucent and electrical glass-fiber post groups (P<.01). In the opaque glass-fiber post group, there were no significant differences between cervical and middle segments. In SEM analysis, a distinct hybrid zone with long, numerous resin tags located between luting material and dentin was exhibited in all post systems. CONCLUSION: The opaque and electrical glass-fiber posts exhibited similar bond strengths, and translucent posts exhibited the lowest bond strength. The highest bond strength was observed in the cervical third of the post spaces for translucent and electrical glass-fiber post groups.

Dental Bonding↗

The in vitro effect of pulpal pressure and luting agent on tensile bond strength of complete cast crowns.

STATEMENT OF PROBLEM: The degree to which pulpal pressure may affect bond strength of complete cast crowns is unknown. PURPOSE: The aim of this in vitro study was to evaluate the effect of simulated pulpal pressure on the tensile bond strength of complete cast crowns luted with 2 different cements. MATERIAL AND METHODS: Forty-eight human mandibular canine teeth were cleaned and stored in saline solution. The crowns were prepared by 1 investigator, and standardization of the preparation was accomplished by fixing a dental handpiece in a parallelometer. Uniform grooves, 0.5 mm in depth, were prepared with burs with depth guides. The complete crowns were prepared with a 0.5-mm shoulder margin. Teeth were randomly divided into 2 groups of 24 teeth each (Group I and Group II). In Group I, bonding and tensile test procedures of the teeth were carried out under simulated pulpal pressure (15 cm of saline solution). In Group II, simulated pulpal pressure was not used. The roots were removed 1 mm below the cementoenamel junction to create direct communication with the pulp chamber. The remaining pulpal tissues were carefully removed, and crowns were embedded in acrylic resin. The acrylic resin was then penetrated by a stainless steel tube that connected the pulp chamber and the barrel of a disposable plastic 5-ml syringe. The pulp chambers were filled with physiological saline solution under elevated pressure to locate the area of greatest permeability on the dentinal surface. Crowns were cast (Co-Cr alloy) with a 20-mm bar to allow testing of the bond strength. Each of the 2 groups were further divided into 2 luting cement groups of 12 each (Group I, A and B, and Group II, A and B). Group IA/IIA and Group IB/IIB specimens were luted with a polycarboxylate luting cement (Poly-F Plus) and an adhesive luting cement (Superbond C&B), respectively. After storage in distilled water for 24 hours, all specimens were subjected to a tensile bond test in a universal testing machine at a crosshead speed of 0.5 mm/min until failure. The maximum load at fracture (Newton) was recorded. The results were then evaluated with 2-way analysis of variance and Tukey's honestly significant difference tests (alpha=.05). RESULTS: Simulated pulpal pressure increased the bond strength of cast complete crowns cemented with an adhesive luting agent (P=.01). No significant difference was found in the bond strength of complete cast crowns cemented with polycarboxylate cement with or without pulpal pressure. Superbond C&B adhesive luting agent showed significantly higher bond strength values for Group I (388.9+/-32.7) and Group II (300.9+/-66.8), when compared with polycarboxylate cement for Group I (221.3+/-17.3) and Group II (186.8+/-38.5) (P=.001). CONCLUSION: Simulated pulpal pressure had a positive effect on the retention of complete cast crowns when cemented with Superbond C&B adhesive luting agent. Superbond C&B significantly increased the retention of crowns in either the presence or absence of pulpal pressure.

Analysis of Variance↗

Influence of different light sources on microleakage of class V composite resin restorations.

UNLABELLED: The aim of this study was to evaluate the effect of three different curing units on microleakage of class V composite restorations. Class V cavities were prepared on the buccal surfaces of 45 extracted premolar teeth. The teeth were randomly divided into three groups of 15 each. A conventional halogen curing unit (Hilux 350), a high intensity halogen curing unit (Optilux 501) and plasma arc curing unit (Power Pac) were used to polymerize composite resin (Vitalesence). After restoration, the teeth were thermocycled for 100 cycles between 5 degrees and 55 degrees C using a dwell time of 30 s and exposed to a dye. Results showed that there was no significant difference among three different curing units (P > 0.05), however the microleakage at the dentin margins was greater than the enamel margins (P < 0.05). CLINICAL RELEVANCE: Plasma arc curing or fast halogen units cure composite materials at a faster rate than conventional curing units because of the high light intensity. High intensity halogen curing units and plasma arc curing units might be useful alternatives in composite polymerization. Therefore, these units are suggested for clinical use to save chair side time.

Composite Resins↗

Nasal prosthesis rehabilitation: a case report.

A nasal prosthesis can reestablish esthetic form and anatomic contours for midfacial defects often more effectively than can surgical reconstruction. This case report describes the clinical and laboratory procedures for fabricating a nasal prosthesis.

Aged↗

Dimensional changes and water sorption of two acrylic polymer materials reinforced with glass fibres.

The purpose of this study was to examine the effect of glass fibre reinforcement on the dimensional changes and water sorption of a heat-polymerising denture acrylic polymer and a microwave-polymerising denture acrylic polymer. Fifteen specimens from each group were prepared with 2% by weight (18 mg) E-glass fibre and 15 without glass fibre. The dimensional change measurements were made at three different stages on the 60 specimens. The water sorption calculations were made on specimens immersed in distilled water at 37 degrees C +/- 1 degree C for 0, 1 and 7 days. Glass fibre reinforcement and processing method do not affect the dimensional change of test specimens, but as the time increased the dimensional change decreased. The glass fibre reinforcement decreased water sorption, but the two processing methods failed to show a significant difference.

Absorption↗

Temperature rise during adhesive and resin composite polymerization with various light curing sources.

This study evaluated the temperature rise in two different adhesive (Clearfil SE Bond [CSEB] and EBS-Multi [EBSM]) and composite systems (Clearfil AP-X [CAPX,] Pertac II [PII]) by the same manufacturer when illuminated by four different light sources: Light-emitting diode (LED), Plasma arc curing (PAC), high intensity quartz tungsten halogen (HQTH) and quartz tungsten halogen (QTH). Forty dentin disks were prepared from extracted premolars. These dentin disks were placed in apparatus developed to measure temperature rise. Temperature rise during photopolymerization of adhesive resin and resin composite was then measured. The mean values of temperature increases for adhesive and resin composites did not differ significantly (p=0.769). The highest temperature rise was observed during photopolymerization of EBSM with PAC (5.16 degrees C) and HQTH (4.28 degrees C), respectively. Temperature rise values produced by QTH (1.27 degrees C - 2.83 degrees C for adhesive resin; 1.86 degrees C - 2.85 degrees C for resin composite) for both adhesive and resin composites were significantly lower than those induced by PAC and HQTH (p<0.05). However, these values were significantly higher than those produced by LED (1.16 degrees C - 2.08 degrees C for adhesive resin; 1.13 degrees C - 2.59 degrees C for resin composite). Light sources with high energy output (PAC and HQTH) caused significantly higher temperature rise than sources with low energy output (QTH and LED). However, in this study, no temperature rises beneath 1-mm dentin disk exceed the critical 5.6 degrees C value for pulpal health.

Analysis of Variance↗