PubMed Health⌕ Search

Biomedical subjects

A Nordwall

Publications and source records attributed to A Nordwall.

47 records · Page 3Linked to original sources

A late neurologic complication of scoliosis surgery in connection with syringomyelia.

A case of scoliosis in connection with syringomyelia is described. Theories are proposed to explain the progression of the neurological symptoms after surgical correction and fusion of the deformity. Special points are emphasized that will aid in the recognition of syringomyelia in scoliosis patients. i) Abnormal neurology, in particular a dissociated disturbance of pain and temperature in the upper extremity. ii) Abnormal localization of a scoliosis curve. iii) Rapid progression of the scoliosis. iv) Bony anomalies of the upper cervical spine. v) Increased diameter of the cervical spinal canal.

Adolescent↗

Effectiveness of preoperative Cotrel traction for correction of idiopathic scoliosis.

Of 206 patients less than twenty years old with idiopathic scoliosis of 40 to 90 degrees treated with Harrington distraction rods and fusion, ninety had preoperative Cotrel traction and 116 received no immediate preoperative treatment. There was no significant difference between these two groups in terms of the immediate surgical correction obtained. Cotrel traction therefore did not improve the results of treatment of idiopathic scoliosis of this degree in this age group.

Adolescent↗

Wound strength in a clinical material.

A number of investigations on wound strength have earlier been performed, though mostly in experimental animals and on laboratory tissue; comparisons with human tissue are lacking. In this study, the breaking strength of wounds sutured with two different suture materials, polyglycolic acid (Dexon) and a synthetic polyamid (Supramid) was studied in a human material of 56 patients operated for scoliosis in two stages. Wound thickness and wound length (wound area) were considered in the determination of breaking strength. The breaking strength of a 14-day-old wound was about 57 N/cm2 wound area, a value which is quite comparable to the values obtained in experiments on wound healing in animals, such as rats and rabbits. Those experiments can thus be considered relevant also for human tissue. All wounds healed uneventfully and no difference in strength was noticed in wounds sutured with the two different suture materials.

Adolescent↗

A study of skeletal age and height in girls with idiopathic scoliosis.

The height and skeletal age of girls with idiopathic scoliosis were studied. The skeletal age was evaluated by two independent methods and was compared with the chronological age and the corrected height of the patients. With both methods the same tendency was noticed. Early in the adolescence (ages 11 and 12 years) the skeletal development was more advanced in girls with idiopathic scoliosis than expected. Later (ages 16 and 17 years) the reverse condition was found. The standing height, corrected for the deformity, was significantly greater in idiopathic scoliosis patients than in controls of either the same chronological or skeletal age. These observations indicate that girls with adolescent idiopathic scoliosis have a growth pattern differing from normal, and that growth factors are connected to the disease.

Adolescent↗

Spinal cord monitoring using evoked potentials recorded from feline vertebral bone.

A new recording method for continuous spinal cord monitoring has been developed at Rancho Los Amigo Hospital. Using peripheral nerve stimulation, spinal evoked potentials (SEPs) are recorded from cancellous bone of spinous processes. This neurologically noninvasive technique provides a highly reproducible and consistent signal, unaffected by biologic noise and surgical handling of the spinal column. Moreover, the evoked response is extremely sensitive to changes in functional integrity of the spinal cord. In experimental spinal cord injuries, produced by localized distraction of the spine, changes of the evoked responses were well correlated with the change in spinal cord function.

Animals↗

The role of the anterior longitudinal ligament in Harrington rod fixation of unstable thoracolumbar spinal fractures.

This study was carried out to identify the role of the anterior longitudinal ligament in Harrington distraction rod fixation of the unstable spine, and to suggest clinical means of detecting a ruptured ligament when this is not obvious from a preoperative radiogram. In the unstable thoracolumbar spine, a marked difference in force is required for distraction and stabilization when the ligament is intact compared with when the ligament is disrupted. This can be detected by using a force-indicating distractor during the procedure. Furthermore, when the anterior longitudinal ligament is disrupted, the pattern of vertebral movements during distraction is altered. With the ligament intact, the vertebrae adjacent to the unstable segment will angulate around an axis situated ventral to the vertebral bodies, while the vertebrae will move apart in parallel planes when the ligament is severed. This can easily be detected by studying the movements of Kirschner wires inserted into the spinous processess.

Adult↗

Transverse traction in the treatment of scoliosis. A preliminary report.

Nineteen scoliotic patients were treated with the standard Harrington distraction rod supplemented with transverse traction. The latter consists of a compressive device (either Harrington';s or Cotrel's) applied to the convex side of the curve to correct disc space wedging and then drawn toward the distraction rod with a simple traction apparatus. Intraoperative roentgenograms were taken with the Harrington distraction rod alone after maximal distraction was applied. This was followed by postoperative roentgenograms with the transverse traction added. The 50.3% correction by distraction rod alone is increased to 66% with the addition of transverse traction. Detailed analysis of each curve, segment by segment, showed that the correction was augmented, not only in the center of the curve, where the compression corrected disc space wedging, but in the ends of the curve as well. This series uses each patient as his or her own control in demonstrating increased correction added by transverse traction.

Adolescent↗

Correction of spinal curvatures by transcutaneous electrical muscle stimulation.

Transcutaneous electrical neuromuscular stimulation was used to induce acute scoliosis of up to 56 degrees in straight cat spines. Conversely in humans, surface muscle stimulation was able to acutely correct 35 idiopathic scoliosis curves an average of 44%. The amount of correction obtained increased linearly with the length of the skeletal lever arms (ribs, pelvis) interconnecting the stimulated musculature with the vertebrae of the spinal curve. When the electrodes were placed over the lateral trunk musculature rather than on the paraspinals, the scoliosis reduction improved threefold. Similar results were found in a group of seven neuromuscular scoliotics. Muscle groups stimulated were detected with thermography. In 18 kyphosis patients, an average of 13 degrees correction was accomplished with stimulation of the paraspinal musculature. The foundation for clinical use of surface muscle stimulation in the management of excessive spinal curvatures was established, with guidelines for electrode placement in scoliosis, kyphosis, lordosis, and curvature combinations.

Adolescent↗

Reduction, stability, and strength provided by internal fixation systems for thoracolumbar spinal injuries.

Anterior, posterior, and combined thoracolumbar spinal injuries were simulated in human cadaver specimens and then stressed in flexion, before and after stabilization, with Weiss Springs, Roy-Camille plates, vertebral body plates, and Harrington compression and distraction rods. The reduction, stability, and strength were determined for each implant-injury combination. For posterior ligamentous injuries, the Harrington compression system on the laminae gave reduction in extension, stability to that of the intact spine, and failure at 87.6 Nm bending load with 14.1 J energy absorption. For anterior vertebral body fracture, Harrington distraction rods from three vertebrae above to three below the injury gave a reduction in extension with stability similar to that of the intact spine. Failure occurred at 81.6 Nm load, one-third greater than with rods two levels above to two below, and 14.0 J energy absorption, twice that for the short rod. The more unstable combined anterior and posterior injury was satisfactorily reduced only by the long distraction system, which failed at 44.1 Nm load, twice that for the short rod, and 5.7 J energy absorption. By accurately determining what structures have been injured, and appropriate fixation device can be selected and the strength of the stabilized spine estimated. A thorough understanding of the biomechanics of the spine is essential for successful clinical utilization of these experimental data.

Aged↗