Physical bone changes in carragheenin-induced arthritis evaluated by quantitative computed tomography.

Repeated non-invasive measurements were performed in dogs of trabecular bone density (TBD), low density bone area (LDBA), and high density bone area (HDBA) in chronic arthritis using quantitative computed tomography (QCT). Unilateral chronic arthritis of the knee had been induced by weekly instillation of 2 ml carragheenin into the right knee joint for 12 weeks with the left knee serving as a control. CT scanning of the distal femoral condyles was performed in 12 mature dogs with chronic arthritis. Another 6 dogs underwent a longitudinal CT study starting immediately prior to induction of arthritis. During induction of arthritis TBD decreased (P less than 0.01), LDBA increased (P less than 0.05) and HDBA decreased (P less than 0.01) in the arthritic bone. Opposite changes were found on the control side, i.e. TBD increased (P less than 0.01), LDBA decreased (P less than 0.01) and HDBA increased (P less than 0.01). The chronic arthropathic bone showed 20% lower TBD (P less than 0.0001), greater LDBA (P less than 0.0001) and lower HDBA (P less than 0.0001) as compared with the control bone. Reproducibility tests of TBD showed a coefficient of variation of 0.8%. Indentation tests and histomorphometric analyses confirmed the bone density changes as measured by CT.

Animals

Tensile and compressive properties of cancellous bone.

The relationship between the mechanical properties of trabecular bone in tension and compression was investigated by non-destructive testing of the same specimens in tension and compression, followed by random allocation to a destructive test in either tension or compression. There was no difference between Young's modulus in tension and compression, and there was a strong positive correlation between the values (R = 0.97). Strength, ultimate strain and work to failure was significantly higher in tensile testing than in compressive testing.

Adult

Mechanical properties of trabecular bone. Dependency on strain rate.

The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma u), and ultimate strain (epsilon u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a rho b epsilon c, Y = rho b(a + c epsilon; Y = (a + b rho)epsilon c, Y = a rho 2 epsilon c, E = a rho 3 epsilon c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.

Aged

The underestimation of Young's modulus in compressive testing of cancellous bone specimens.

In order to determine the accuracy of measurements of Young's modulus of cancellous bone by conventional compression testing, two independent strain measurements were made simultaneously during non-destructive uniaxial compression to 0.8% strain of rectangular specimens (n = 18). Strain was measured by an extensometer attached to the compression anvils close to the specimen and by an optical system covering the central half of the specimens. Mean Young's modulus determined by the extensometer technique was 689 MPa, but was 871 MPa when determined by the optical technique (mean difference = 182 MPa, SED = 50 MPa, p less than 0.002). Uneven strain distribution due to lack of support of cut vertical trabeculae at the anvil-specimen interface is believed to be causing the underestimation of Young's modulus measured by the extensometer technique. The influence of friction at the specimen-anvil interface was studied by performing a finite element analysis. It is concluded that Young's modulus of specimens of the chosen geometry on average is underestimated by about 20% by conventional compressing testing. The underestimation seems not to be dependent upon specimen density.

Biomedical Engineering

Estimation of structural anisotropy based on volume orientation. A new concept.

The quantification of anisotropy--its main direction and the degree of dispersion around it--is desirable in numerous research fields dealing with physical structures. Conventional methods are based on the orientation of interface elements. The results of these methods do not always agree with perceived anisotropy, and anisotropic structures do not necessarily turn out to be 'anisotropic' using these methods. In the present paper, we propose an alternative to curve and surface orientation, namely volume orientation. Using trabecular bone as an example of a two-phase anisotropic structure, the new concept is studied in some detail. In particular, a parametric method of estimating volume orientation from sections is presented and discussed.

Adult

A direct method for fast three-dimensional serial reconstruction.

A method for accurate three-dimensional reconstruction of openly connected porous structures is described. The method is based on embedding of a specimen in a contrast coloured epoxy resin and serial sectioning in a standard hard tissue microtome. A PC-based image processing system is used for direct digitization of the cut surface, and by thresholding two-phase images are obtained. The process is fully automated, and about 170 sections can be produced, digitized, dichotomized, and stored per hour. As an example of its applications, the method is used on trabecular bone, which is an anisotropic porous structure.

Bone and Bones

Density changes at the proximal tibia after medial meniscectomy.

Trabecular bone density changes at the proximal tibia were studied after total and partial meniscectomy using quantitative computerized tomography. Thirty-seven medially meniscectomized patients (5- and 10-year follow-up) and 10 control persons were included. In the partially and the totally meniscectomized knees, the area of maximal density in the medial tibial condyle was displaced approximately 4 mm in a posteromedial direction relative to the position in the intact knees. In both partially and totally meniscectomized knees, the density in the region of tibiofemoral contact in the medial tibial condyle was higher compared with the density in the same region in the contralateral intact knees. This difference was of the same order in the 5- and 10-year follow-up groups. The density difference between the meniscectomized and the intact knees in the region of tibiofemoral contact in the medial condyle was significantly higher in totally than in partially meniscectomized patients. It is concluded that not only total but also partial medial meniscectomy is followed by density changes, occurring within the first 5 years after meniscectomy. The results emphasize the importance of the utmost conservatism in surgery on the meniscus.

Adult

Compressive axial strain distributions in cancellous bone specimens.

The compressive axial strain distribution in cylindrical trabecular bone specimens was studied using digitized images of the specimen surface. Specimens were tested with strain rate 0.00015 s-1. Images were taken at 0, 1, 2, 3, 4, 6, 8 and 10% strain. Using an optical illusion of movement by rapidly changing succeeding images, failures were classified as transverse (33%) or oblique collapses (67%). The location of failure was not determined by the specimen density gradient. Local axial strain in the distal, intermediate and proximal third was measured throughout the compression in the transversely failing specimens, whereas local strain in the obliquely failing specimens was measured in the pre-failure phase only. Axial strain inhomogeneity was observed in the pre-failure as well as in the post-failure phase. In the pre-failure phase the intermediate third was strained significantly less than the thirds near the ends. In the post-failure phase specimen strain occurred solely in the collapsed part. Ultimate strain of the transversely failing specimens was 2.5% and ultimate strain of the failing third was 3.7%. At failure less than 1% strain was observed in the intermediate third and at 10% specimen strain 1.5% local strain was found in the intermediate third. The results indicate unreliability of conventional stiffness and strain measurements in trabecular bone specimens probably due to lack of trabecular constraint at the end surfaces. Conventional measurements tend to underestimate stiffness and, by giving an average value of strain in spite of considerable strain inhomogeneity, to underestimate failure strain.

Bone Density