PubMed Health⌕ Search

Biomedical subjects

A Olivo

Publications and source records attributed to A Olivo.

At least 19 recordsLinked to original sources

Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any x-ray imaging system.

Phase contrast (PC) imaging is one of the most exciting emerging x-ray imaging techniques, with the potential of removing some of the main limitations of conventional radiology. After extensive experimentation carried out particularly at synchrotron radiation (SR) facilities, the scientific community agrees that it is now time to translate these ideas towards the first clinical implementations. In this framework, a complete model, based on Fresnel/Kirchoff diffraction integrals, was devised. This model accounts for source dimensions, beam spectrum and divergence and detector point spread function (PSF), and can thus be applied to any x-ray imaging system. In particular, by accepting in input the above parameters along with the ones describing the sample, the model can be used to optimize the geometry of the set-up, i.e. to assess the source-to-sample and sample-to-detector distances which maximize feature detection. The model was evaluated by acquiring a range of images of different samples with a laboratory source, and a good agreement was found between simulated and experimental data in all cases. In order to maximize the generality of the results, all acquisitions were carried out using a polychromatic source and an energy-resolving detector; in this way, a range of monochromatic images could be obtained as well as polychromatic images, which can be created by integrating different parts of the acquired spectra. One of the most notable results obtained is that in many practical cases polychromatic PC imaging can provide the same image quality as its monochromatic counterpart. This is an important step in the wider application of PC using conventional sources.

Algorithms↗

High resolution Ca/P maps of bone architecture in 3D synchrotron radiation microtomographic images.

The Ca/P ratio was measured in cortical bone samples from the femoral neck and tibia of different animal species, using synchrotron radiation microtomography. Use of a monoenergetic X-ray beam, as provided by the synchrotron facility, generates accurate 3D maps of the linear attenuation coefficient within the sample and hence gives the ability to map different chemical components. Also, by comparing normal and abnormal bones, i.e. osteoporotic (induced by inflammation), changes in the Ca/P ratio brought about by bone diseases can be detected. MicroCT data sets were collected at 20 and 28 keV for each bone sample and two calibration phantoms. From the 3D data sets, multiple 2D slices were reconstructed with a slice thickness of approximately 30 microm. Regions of interest were defined around suitable sites and were converted to Ca/P ratios using the data collected from the test phantoms. A significant difference (p<0.001) between osteoporotics and age-matched normals at both energies was detected. Differences between different bone sites from the same animal are not significant (p>0.5) while those between the same bone sites from different animals are highly significant (p<0.001). Differences between estimates made at 20 and 28 keV are not significant (p>0.5). An important aspect is the ability to map the spatial distribution of the Ca/P ratio.

Animals↗

The effects of the imaging system on the validity limits of the ray-optical approach to phase contrast imaging.

A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which the x-ray optical approximation can be used to describe the image formation mechanism have been analyzed, taking into account also the effects due to the finite source size and detector resolution. It is possible to demonstrate that the ray-optics results can also be obtained by opportunely developing the diffraction formalism only with some restrictions on the spatial frequencies present in the final image, without any limitation on the maximum phase shift. The conditions allowing the use of the simplified ray-optical approach to describe the phase contrast images have been here defined and their validation has been proved by means of computer simulations and phantom experiments.

Biophysical Phenomena↗

Signal-to-noise ratio evaluation in dual-energy radiography with synchrotron radiation.

Dual-energy radiography is an effective technique that allows removal of contrast between pairs of materials in order to display details of interest on a uniform background. In mammographic images the detection of small nodules is often impeded by obscuring background 'clutter' resulting from the contrast between normal tissues (glandular and adipose) in their neighbourhood. We consider whether it could be possible to apply dual-energy radiography to the breast, which is hypothetically principally composed of three tissues, glandular, adipose and cancerous, in order to remove the contrast due to the distribution of normal tissues and, as a consequence, to enhance the intrinsic contrast of the pathology. The purpose of this work is to test the limitations of dual-energy radiography on a three-component phantom under optimum conditions of the source and detector. We use a synchrotron monochromatic beam, produced at the ELETTRA synchrotron facility (Trieste, Italy), and an imaging plate detector, in order to acquire two images at low and high energies of a phantom composed of polyethylene, plexiglas and water. For evaluation of the potential of this procedure we studied the signal-to-noise ratio (SNR) of polyethylene and water on a set of images obtained by applying the dual-energy procedure. We found that the SNR of polyethylene and water is around the detectability threshold (according to Rose's criteria) at the contrast cancellation angles. Finally we evaluated the air entrance dose required for this double exposure, resulting in 0.81 mGy for the low-energy image and 0.01 mGy for the high-energy image. To obtain the same image quality for a standard breast of 5.5 cm, mean glandular doses of 3.50 mGy and 0.03 mGy at 17 keV and at 34 keV, respectively, are required.

Algorithms↗

Preliminary study on extremely small angle x-ray scatter imaging with synchrotron radiation.

Among the medical physics community, there is nowadays a great interest in the possible implementation of scatter imaging techniques, especially in the field of breast imaging. It is well known that malignant lesions and normal tissue differ in their scattering signatures, and thus scattered radiation can provide a powerful tool to distinguish between the two cases. Up to now, most of the proposed techniques rely on the detection of radiation scattered at angles of the order of a few degrees, which in most cases results in very high contrast values. On the other hand, at those relatively large angles the scattered flux is relatively low with respect to the primary, which often implies the necessity of increasing the dose delivered to the sample in order to achieve sufficient statistics. Furthermore, most of these techniques are based on pencil beam set-ups, which results in an increase of the overall duration of the examination. We propose here an alternative approach based on the detection of radiation scattered at extremely small angles, of the order of approximately 100-200 microrad. This results in a relatively high scattered flux (5-10% of the primary) and in the possibility of utilizing a fan beam geometry, which reduces the acquisition times with respect to pencil beam set-ups. Images of several samples have been acquired, demonstrating that the proposed technique results in an increased contrast with respect to absorption imaging. Possible in vivo implementations of the technique at no dose expense are finally discussed.

Algorithms↗

An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the medical field. On the other hand, digital radiology is undergoing a wide diffusion, and its benefits are presently very well understood. Up to now, however, the strong pixel size constraints associated with phase contrast pattern detection limited the possibility of exploiting the advantages of phase contrast in digital radiology applications. In this paper, an innovative setup capable of removing the pixel size constraints, and thus opening the way to low dose digital phase contrast imaging, is described. Furthermore, we introduce an imaging technique based on the detection of radiation scattered at small angles: the information extracted from the sample is increased at no dose expense. We believe that several radiological fields, mammography being the first important example, may benefit from the herein described innovative imaging techniques.

Diagnostic Imaging↗

Experimental evaluation of a simple algorithm to enhance the spatial resolution in scanned radiographic systems.

In order to ensure an early diagnosis of breast cancer, an imaging system must fulfil extremely stringent requirements in terms of dynamic range, contrast resolution and spatial resolution. Furthermore, in order to reduce the dose delivered to the patient, a high efficiency of the detector device should be provided. In this paper the SYRMEP/FRONTRAD (SYnchrotron Radiation for MEdical Physics/FRONTier RADiology) mammography project, based on synchroton radiation and a novel solid state pixel detector, is briefly described. Particular relevance is given to the fact that the radiographic image is obtained by means of a scanning technique, which allows the possibility of utilizing a scanning step smaller than the pixel size. With this procedure, a convolution between the real image and the detector point spread function (PSF) is actually acquired: by carefully measuring the detector PSF, it is possible to apply a post-processing procedure (filtered deconvolution), which reconstructs images with enhanced spatial resolution. The image acquisition modality and the deconvolution algorithm are herein described, and some test object images, with spatial resolution enhanced by means of the filtered deconvolution procedure, are presented. As discussed in detail in this paper, this procedure allows us to obtain a spatial resolution determined by the scanning step, rather than by the pixel size.

Algorithms↗

Mammography with synchrotron radiation: phase-detection techniques.

The authors evaluated the effect on mammographic examinations of the use of synchrotron radiation to detect phase-perturbation effects, which are higher than absorption effects for soft tissue in the energy range of 15-25 keV. Detection of phase-perturbation effects was possible because of the high degree of coherence of synchrotron radiation sources. Synchrotron radiation images were obtained of a mammographic phantom and in vitro breast tissue specimens and compared with conventional mammographic studies. On the basis of grades assigned by three reviewers, image quality of the former was considerably higher, and the delivered dose was fully compatible.

Absorption↗

Strong association of HLA class II sequences in Mexicans with Vogt-Koyanagi-Harada's disease.

Vogt-Koyanagi-Harada's syndrome (VKH) is an autoimmune disease prevalent in Mongoloids with evident participation of HLA. The aim of this study was to identify the class II DNA sequences involved in the etiopathogenesis of VKH in Mexican Mestizos. This study included 46 VKH patients and 170 controls. 75% were females (mean age at onset of 33.5 years). The disease evolved to chronicity (68%) and 25% of the patients were unresponsive to corticotherapy. DNA typing of HLA-DRB1, DQA1 and DQB1 was done following the 12th International Histocompatibility protocols. VKH was strongly dependent of DRB1 gene; DRB1*04 was found in 78.2% of the patients vs. 50.6% of the controls (p = 0.001). No particular DRB*04 subtype was significantly increased, suggesting that residues E-9 V-11; H-13; H-33 and Y-37 shared by all DR4s are implicated in susceptibility to VKH. However DRB1*0101 (p = 0.009, OR = 4.2) was clearly associated. This allele shares the motif LLEQRRAAG located at position 67-74 and 86 of DRB1 with *0405 associated in Japanese. Two HLA associated mechanisms may be triggering the autoimmune phenomena. One involving critical polymorphic residues expressed in different alleles. Secondly, some peptides may anchor to the conserved residues leaving other sequences to bind to the T cell receptor.

Adult↗

Molecular analysis of HLA class I alleles in the Mexican Seri Indians: implications for their origin.

The molecular analysis of HLA class I loci has demonstrated that, although, the genetic profile is restricted in Amerindians, several micropolymorphisms may be important in conferring a biological advantage. We analyzed the HLA-A and B genetic profile of Seris, a Mexican Indian tribe living in northwestern Mexico in the state of Sonora. There are presently only 619 individuals. Our study included 100 Seris belonging to nine families. HLA-A and -B loci typing was performed by polymerase chain reaction using an amplification refractory mutation system (PCR-ARMS) on a select group of samples; all of them were typed by polymerase chain reaction using sequence-specific oliogonuoleotide probes (PCR-SSOP) at a low-intermediate resolution level. The correlation between the techniques was 100%. Only five HLA-A alleles and seven HLA-B alleles were found. A*0201, A*68, A*31, A*24, B*3501, B*40, B*51, B*3512 and B*15 were present in over 5% of the individuals. B*27052 was detected in 2%. B27 is absent in any other Mexican Indian groups previously studied. The presence of B27 may be the result of a founder effect due to different waves of southward migrations. The B-locus is more diverse and the prevalent haplotypes were: A*0201-B*3501, A*0201-B*40, A*0201-B*3512, A*31-B*51, A*68-B*3501 and A*68-B*40. This genetic profile is different from the pattern of other Mexicans. The phylogenetic tree suggests that Seris are more closely related to the Warao Indians from Venezuela, who live in a similar ecosystem, and to some groups of Argentina, than they are to the Mexican Lacandones who live in the jungle. These data emphasize the relevance of the interaction between genes and environment.

Genetics, Population↗

HLA DOA1 and DOB1 loci in Honduran women with cervical dysplasia and invasive cervical carcinoma and their relationship to human papillomavirus infection.

Molecular and epidemiological studies have demonstrated that certain types of human papillomavirus (HPV), mainly HPV-16 and HPV-18, are the primary causes of cervical cancer and its precursor lesions; there is now evidence for a clear association with specific HLA class I and class II loci contributing independently to the expression of cervical cancer. Among Honduran women carcinoma of the cervix is the most common type of cancer, and infections with high-risk HPV types are highly prevalent. To study the interactive role of viral-host genetics, we performed PCR amplification of DNA and sequence-specific oligonucleotide probe typing on cervical scrapes from 49 women [24 with cervical intraepithelial neoplasia stage III or cervical cancer (severe cases) and 25 with stage I or II cervical intraepithelial neoplasia (mild cases)] and 75 control subjects to look for possible associations between HPV and HLA class II DQA1 and DQB1 alleles in the development of dysplasias and invasive cancer. This analysis revealed a predominance of HLA-DQA1*0301 among severe-case patients [relative risk (RR) = 3.45, p = 0.008), whereas DQA1*0501 was negatively associated (RR = 0.30, p = 0.03), suggesting a protective effect of this allele. HPV typing showed a decreased relative risk among the HPV-16 or HPV-18 carrying patients and other HPV-related positive patients in the presence of DQB1*0602 compared with positive control subjects (p = 0.04). No statistically significant allele frequency difference was observed between mild dysplasia cases and control subjects. The results suggest that DQA1*03011, which is in linkage desequilibrium with all HLA-DR4 alleles, confers an increased risk for severe cervical dysplasia and invasive cancer, whereas DQA1*0501, which is in several DR52 haplotypes, has a protective effect. Furthermore, specific HLA-DQB1 sequences may be important in determining the immune response to HPV peptides and may affect the risk for cervical cancer after HPV infection in mestizo Honduran women.

Adult↗

MHC class II sequences of susceptibility and protection in Mexicans with autoimmune hepatitis.

BACKGROUND/AIMS: Autoimmune hepatitis has a genetic background associated with different HLA DRB1 alleles depending on the ethnic group. The aim of this study was to analyse the immunogenetics of type I autoimmune hepatitis in Mexicans. METHODS: Thirty Mexican Mestizo patients and 175 healthy controls were HLA typed as follows: class I antigens were determined by microlymphocytotoxicity and class II typing was done on DNA samples using PCR-SSO and PCR-SSP for DRB1, DQA1 and DQB1 loci. RESULTS: A significant association of autoimmune hepatitis with DRB1*0404 was found, (chi2Y=19.95, pc=0.002, RR=7.71), suggesting the presence of a susceptibility gene located at the DRB1 locus. Resistance was at least partially due to a DQB1 gene, since a significant decrease in DQB1*0301 was also detected (chi2Y=8.21, pc=0.04). Analysis of subgroups according to age at onset showed an association with DRB1*0404 (chi2Y=4.31, p=0.04) in patients with late onset (after 30 years), while DQA1*0501 (chi2Y=5.12, p=0.02) was increased in the early onset group. CONCLUSIONS: The possible mechanism of HLA association is due to "shared epitopes", since DRB1*0404, and those found in other populations namely, DRB1*0401, *0405 and *0301 share almost the same sequence at position 67-72 (LLEQRR, R or K at 71). Valine-86 is also relevant to the age at onset because DRB1*0404 is increased in the patients with an average age at onset of 32. These findings are relevant in determining which peptides in the liver are targets for T cells.

Adult↗

Relevant residues of DRbeta1 third hypervariable region contributing to the expression and to severity of rheumatoid arthritis (RA) in Mexicans.

Rheumatoid arthritis (RA) is a chronic autoimmune disease leading to destruction of the joints. Residues at positions 67-74 of the DRB1 third hypervariable region are involved in susceptibility (S) and resistance (P) to RA. DNA from 83 patients and 175 controls, all of them Mexican Mestizos were oligotyped using PCR-SSOP and PCR-SSP. The (S) alleles are DRB*0404 (p = 0.000004), *0401 (p = 0.007) and *1001 (p = 0.008). Those associated with P are DRB1*0701 (p = 0.0001); *1101 (p = 0.01); *1503 (p = 0.02); *0801 (p = 0.04); *1401 (p = 0.04). Susceptibility/protection are recessive traits; SS genotypes are increased in the patients (p = 0.0003) while PP genotypes are decreased in them (p = 0.00004). The motif at 67-74 and the valine or glycine at position 86 are relevant in the development and severity of RA in Mexicans. The associations suggest that residues 67, 70, 71 are central for susceptibility. The P alleles have D-70 or carry V-86 in the absence of D-70. Thus, susceptibility/protection depends on the combination of basic residues at these positions and a non-polar aa at 86 contributes to resistance. Severity is also HLA influenced. DQA1*03011-DQB1*0302 are associated to severe lesions in the presence of any DR4 subtype. Analyzing different ethnic groups is essential to elucidate the etiopathogenesis of RA.

Adult↗

Low-dose phase contrast x-ray medical imaging.

Phase contrast x-ray imaging is a powerful technique for the detection of low-contrast details in weakly absorbing objects. This method is of possible relevance in the field of diagnostic radiology. In fact, imaging low-contrast details within soft tissue does not give satisfactory results in conventional x-ray absorption radiology, mammography being a typical example. Nevertheless, up to now all applications of the phase contrast technique, carried out on thin samples, have required radiation doses substantially higher than those delivered in conventional radiological examinations. To demonstrate the applicability of the method to mammography we produced phase contrast images of objects a few centimetres thick while delivering radiation doses lower than or comparable to doses needed in standard mammographic examinations (typically approximately 1 mGy mean glandular dose (MGD)). We show images of a custom mammographic phantom and of two specimens of human breast tissue obtained at the SYRMEP bending magnet beamline at Elettra, the Trieste synchrotron radiation facility. The introduction of an intensifier screen enabled us to obtain phase contrast images of these thick samples with radiation doses comparable to those used in mammography. Low absorbing details such as 50 microm thick nylon wires or thin calcium deposits (approximately 50 microm) within breast tissue, invisible with conventional techniques, are detected by means of the proposed method. We also find that the use of a bending magnet radiation source relaxes the previously reported requirements on source size for phase contrast imaging. Finally, the consistency of the results has been checked by theoretical simulations carried out for the purposes of this experiment.

Biopsy↗

Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector.

A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined with a synchrotron radiation beam allows acquisition of high-contrast, low-dose images of soft tissues.

Breast↗

A linear array silicon pixel detector: images of a mammographic test object and evaluation of delivered doses.

We present images of a mammographic test object obtained using a linear array silicon pixel detector capable of single-photon counting. The detector pixel size was 200 x 300 microns2 and images were acquired by scanning the test object between the laminar detector and the x-ray source with a scanning step of 100 microns. A molybdenum anode tube was used with two different filtrations: 2 mm aluminium and 25 microns molybdenum. Conventional film-screen images were also obtained in order to compare spatial and contrast resolution. In our digital images it is possible to recognize low-contrast details having dimensions smaller than or equal to the dimensions of details visible by means of a clinical mammographic unit. The detection of microcalcifications smaller than 150 microns was possible only when using the Mo filtration. However a copper wire of 50 microns diameter was detectable when embedded in a simulated tissue. We discuss in detail the mean glandular doses (MGDs) delivered during the image acquisition. The MGDs necessary to obtain good-quality images are always smaller than at a conventional mammographic unit. Since MGDs depend on the x-ray spectrum, the dose reduction becomes larger when the applied spectrum is harder than in film-screen acquisition (Al filtration and 35 kVp).

Female↗

HLA-DRB1*08 influences the development of disease in Mexican Mestizo with spondyloarthropathy.

OBJECTIVE: HLA class II encoded factors may influence the phenotype of ankylosing spondylitis (AS). These include HLA DRB1*07 for peripheral arthritis, and polymorphism of the HLA-linked LMP2 locus and HLA DRB1*08 for acute anterior uveitis (AAU). We studied the relationship between DRB1*08 and disease phenotype in additional populations of individuals with AS. METHODS: The patient population included 385 unrelated HLA-B27 positive individuals with AS. These included 204 Caucasians and 2 populations of Mexican Mestizo with AS: 106 with predominately adult onset disease from Guadalajara and 75 with predominately juvenile onset disease from Mexico City. The control population of 428 individuals included 210 random and 36 HLA-B27 positive unrelated Canadian Caucasians and 173 random and 9 HLA-B27 positive Mexican Mestizo from Mexico City. DRB1*08 typing was by sequence specific polymerase chain reaction. RESULTS: A significantly higher prevalence of DRB1*08 was observed in Mexican patients with juvenile onset disease (44.9%) and especially those with undifferentiated spondyloarthropathy (55.6%) compared to normal unrelated Mexican Mestizo (25.4%) (p < 0.01 for both) and in patients with undifferentiated spondyloarthropathy versus B27 controls (11.1%) (p = 0.03), although no significant differences were observed in within patient group comparisons based on phenotypic features of disease such as AAU and age at onset. No significant relationship between DRB1*08 and disease phenotype was evident in Caucasian individuals. CONCLUSION: Our data suggest DRB1*08 may influence the phenotype of spondyloarthritis in Mexican Mestizo, but do not support the view that DRB1*08 influences the development of AAU, as reported in a Japanese population.

Adolescent↗

[High- and low-risk molecular sequences in autoimmune diseases. An analysis of type I diabetes in Latin America].

Type I diabetes is an autoimmune and a polygenic disease, in which MHC-class II genes contribute to 48% of the disease. The aim of the present study, is to provide a guideline to understanding the molecular association of these genes, through the immunogenetic analysis of 3 Latin american mestizo populations. We included 606 individuals, 349 patients with DMDI and 257 healthy controls coming from 3 geographical areas: Mexico City, Mexico; Caracas, Venezuela and Medellin, Colombia. The results clearly indicate that in mestizo groups, the diabetogenic haplotypes are from mediterranean ancestry, while protection is due to Amerindian genes. It was demonstrated that the relevant sequences for IDDM expression are located to DRB1 and DQB1 loci with a minimal contribution of DQA1 residues. The sequences determining peptide recognition and the induction of TH1 cells mediating the cellular autoimmune response are in positions DRB1-57 and 74 (an aspartic acid and a glutamic acid respectively, confer protection), modulated by D-57 in the DQ, 8 chain. These data show that DRB1-DQB1 haplotypes are central for IDDM expression and open new pathways for the disease management.

Adolescent↗