PubMed Health⌕ Search

Biomedical subjects

A Osiecki

Publications and source records attributed to A Osiecki.

4 recordsLinked to original sources

Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Meaningful comparison of single-photon emission tomographic (SPET) reconstructions for data acquired over 180 degrees or 360 degrees can only be performed if both attenuation and scatter correction are applied. Convolution subtraction has appeal as a practical method for scatter correction; however, it is limited to data acquired over 360 degrees. A new algorithm is proposed which can be applied equally well to data acquired over 180 degrees or 360 degrees. The method involves estimating scatter based on knowledge of reconstructed transmission data in combination with a reconstructed estimate of the activity distribution, obtained using attenuation correction with broad beam attenuation coefficients. Processing is implemented for planes of activity parallel to the projection images for which a simplified model for the scatter distribution may be applied, based on the measured attenuation. The appropriate broad beam (effective) attenuation coefficients were determined by considering the scatter buildup equation. It was demonstrated that narrow beam attenuation coefficients should be scaled by 0.75 and 0.65 to provide broad beam attenuation coefficients for technetium-99m and thallium-201 respectively. Using a thorax phantom, quantitative accuracy of the new algorithm was compared with conventional transmission-based convolution subtraction (TDCS) for 360 degrees data. Similar heart to lung contrasts were achieved and correction of 180 degrees data yielded a 10.4% error for cardiac activity compared to 5.2% for TDCS. Contrast for myocardium to ventricular cavity was similarly good for scatter-corrected 180 degrees and 360 degrees data, in contrast to attenuation-corrected data, where contrast was significantly reduced. The new algorithm provides a practical method for correction of scatter applicable to 180 degrees myocardial SPET.

Algorithms↗

Correction of partial volume effects in myocardial SPECT.

BACKGROUND: Marked partial volume effects occur in myocardial single photon emission computed tomographic (SPECT) studies because of limited resolution in imaging the myocardial wall and contractile motion of the heart. Little work has been undertaken to develop correction techniques for SPECT except for efforts to improve the reconstructed resolution. Our purpose was to examine the extent of the problem and propose a correction method. METHODS AND RESULTS: A potential correction method, developed initially for positron emission tomography, involved estimation of extravascular density by means of subtracting vascular density derived in a blood pool study from total density derived from a transmission study. Provided partial volume errors are the same for transmission and emission data, activity per gram of extravascular tissue can be obtained by means of dividing the perfusion regional data by extravascular density for the same region. Simulations were designed to assess the importance of partial volume errors and the use of extravascular density to correct the errors. Recovery coefficients for the myocardium were estimated by means of simulation of the beating heart on the basis of published values for ventricular dimensions. Resolution for transmission with a scanning line source system was compared with emission resolution. The effect of spillover on measured partial volume losses was assessed, and a method for matching spillover for emission and extravascular density was demonstrated. Correction for partial volume effects was demonstrated for a phantom with variable wall thickness. Significant variation in recovery coefficient was demonstrated between posterior and septal walls for individual patients independent of heart size. Filtering was necessary to account for the difference in transmission resolution measured in the axial direction. Spillover effects had a significant influence on the measured recovery for small objects; however, for a specific reconstruction algorithm and defined region size, correction was implemented to match the spillover effects for emission and extravascular density. Use of extravascular density for correction of partial volume loss, for ordered subsets expectation maximization reconstruction with compensation for resolution, was demonstrated to be accurate to within 10%. CONCLUSIONS: The feasibility of correcting partial volume effects with extravascular density was demonstrated. Correction is effective provided care is taken to match both resolution and spillover for emission and extravascular density.

Algorithms↗