PubMed Health⌕ Search

Biomedical subjects

A P Azevedo

Publications and source records attributed to A P Azevedo.

6 recordsLinked to original sources

Haematological and histopathological findings after ovariectomy in Trypanosoma cruzi infected mice.

The aim of this study was to investigate the influences of ovariectomy on histopathological and hematological parameters during the course of Trypanosoma cruzi infection. Hematological and immunological homeostasis is influenced by gonadal steroid hormones. Ovariectomy exerts profound influences on parasitic diseases including T. cruzi infection through modulation of the host's immune response. Three groups of female Mus musculus were infected with 4000 blood trypomastigotes of the Y strain of T. cruzi. One group was subjected to ovariectomy, another to simulated surgery before the infection, and a third group of unoperated animals were used as controls. Marked differences were detected in the responses of blood and tissue parasites. On day 9, post-infection parasitism was significantly higher in ovariectomized animals (P<0.05). These results were confirmed by histopathological studies, in which ovariectomized animals displayed hearts with higher number of amastigote burdens, increased inflammatory infiltrate, enhanced tissue fibers disorganization and decreased lytic antibody percentage, when compared to their counterparts. On day 9 the hematological changes were more apparent, with a decrease in erythrocytes, platelets and leucocytes for ovariectomized infected animals. Simulated surgery, as a stressful agent, did not cause any imbalance in parasitism or in the hemogram profile. The results confirm the importance of the female steroids in resistance against T. cruzi infection.

Analysis of Variance↗

A unified approach to the design of clinical reporting systems.

Computer-based Clinical Reporting Systems (CRS) for diagnostic departments that use structured data entry have a number of functional and structural affinities suggesting that a common software architecture for CRS may be defined. Such an architecture should allow easy expandability and reusability of a CRS. We report the development methodology and the architecture of SISCOPE, a CRS originally designed for gastrointestinal endoscopy that is expandable and reusable. Its main components are a patient database, a knowledge base, a reports base, and screen and reporting engines. The knowledge base contains the description of the controlled vocabulary and all the information necessary to control the menu system, and is easily accessed and modified with a conventional text editor. The structure of the controlled vocabulary is formally presented as an entity-relationship diagram. The screen engine drives a dynamic user interface and the reporting engine automatically creates a medical report; both engines operate by following a set of rules and the information contained in the knowledge base. Clinical experience has shown this architecture to be highly flexible and to allow frequent modifications of both the vocabulary and the menu system. This structure provided increased collaboration among development teams, insulating the domain expert from the details of the database, and enabling him to modify the system as necessary and to test the changes immediately. The system has also been reused in several different domains.

Artificial Intelligence↗

Modification of the OMED nomenclature: a system approach based on the SISCOPE data model.

The OMED nomenclature represented a turning point in endoscopic computer systems by supplying software developers with an internationally recognized scientific document on which prototypes could be based. The main pitfalls of the OMED system are related to its hierarchical structure, probably not the most effective design to represent endoscopic findings. Based on our experience during the development of SISCOPE, an integrated data management system for endoscopy, an alternative scheme is proposed: Endoscopic descriptions are modeled as a set of objects represented by a data structure whose elements are location, morphology, associated lesions and hemorrhage. 72 objects appear to be sufficient for an accurate representation of all endoscopic scenes and a consistent data model could be created with this approach. Efforts should be made to decrease redundancy in the OMED nomenclature, but extension to other endoscopic data types, such as clinical and pathological diagnosis, is more urgently required. Furthermore, if data exchange between systems is desired, the definition of an Endoscopy Metafile is an absolute requirement.

Database Management Systems↗

SISCOPE: a multiuser information system for gastrointestinal endoscopy.

SISCOPE is an integrated data management system for use in gastrointestinal endoscopy units which operates in the multiuser mode on UNIX minicomputers or MS-DOS personal computers and can be used for patient bookings, endoscopic data entry and retrieval, and automatic report generation in upper gastrointestinal endoscopy, proctologic examinations, colonoscopy and peritoneoscopy. The description of endoscopic findings is remarkably detailed and data entry very rapid due to an advanced design of input screens that incorporates several recent concepts, including windows, menu bars and pull-down menus; typing is eliminated as data is entered with a mouse by pointing at options within menus. Endoscopic findings can be described under eight headings: morphology, topography, qualifiers, modifiers, signs of bleeding, endoscopic diagnosis, pathological diagnosis and etiology. Terminology is based strictly 3on the OMED system. SISCOPE also allows recording of details on endoscopic procedures, indications for the examination, preparation, premedication, complications and late entry of pathology reports. After entering all data, a report in natural language is produced automatically, the entire process taking one minute on average. Data retrieval programs give on-line access to previous examinations of a given patient and automatically generate activity reports. A formal language allows direct queries to the database and transfer of data for statistical analysis or other data processing. The system is simple to learn and use because operation is intuitive and all endoscopic techniques share the same basic menu structure and screen design.

Computer Systems↗

[Assessment of quality of obstetric hospital care: use of corticoid in preterm labor].

This study aimed to assess quality of obstetric care for preterm labor patients, using referents, indicators, and standards derived from scientific evidence, focusing on antenatal corticotherapy. Available meta-analyses and randomized controlled trials were examined to establish referents, defining indicators and estimating process and outcome standards for the present study. Data from hospital discharge summaries of seven public maternity hospitals in Rio de Janeiro were analyzed. The standard of process used was 100%. It was not possible to estimate outcome standards, since the necessary adjustment for gestational age was not feasible. Utilization of antenatal corticotherapy in the present study was very low, about 4% and 2%, considering patients up to 33 weeks and 6 days and 36 weeks and 6 days, respectively. Failure to use antenatal corticotherapy when formally indicated deserves attention by health planners and managers, considering: a) the ease in incorporating such a technology, in contrast to the adequate incorporation of special/intensive neonatal care; b) benefits and costs associated with this technology compared to those of delivering neonatal care to premature babies.

Adrenal Cortex Hormones↗

[Structuring a clinical information system for hospital services: BASELINE].

Clinical database systems have been in use since 1972, but they still fail to meet most of the requirements they were aimed at. This includes not only the management of administrative tasks, but particularly the support of medical activities. Our study presents an experimental model of a clinical database system for general hospitals, mainly dedicated to the support of some basic, fundamental clinical activities, namely the management of baseline patient data. This model is based on a modular concept, and its core is represented by a Minimal Data Base Set designed to meet the specific requirements of each Department and of each distinct area within a Department. The system does not interfere with routine clinical work and tries to offer a high level of services to users. A number of utilitary programs simplify user interaction with the system, such as a menu-driven data-entry program, a semi-automatic codification program that follows the OMS/ICD-9-CM coding system, and a menu-driven program for data retrieval. Basically, this system can be helpful for the automatic edition of clinical reports and the retrieval of patient records meeting conditions specified by the clinician.

Hospital Information Systems↗