Extrinsic compression of an anomalous right coronary artery causing cardiac arrest.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A P Banning.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Acute coronary, cerebrovascular, and peripheral vascular events have common underlying arterial pathology, risk factors, and preventive treatments, but they are rarely studied concurrently. In the Oxford Vascular Study, we determined the comparative epidemiology of different acute vascular syndromes, their current burdens, and the potential effect of the ageing population on future rates. METHODS: We prospectively assessed all individuals presenting with an acute vascular event of any type in any arterial territory irrespective of age in a population of 91 106 in Oxfordshire, UK, in 2002-05. FINDINGS: 2024 acute vascular events occurred in 1657 individuals: 918 (45%) cerebrovascular (618 stroke, 300 transient ischaemic attacks [TIA]); 856 (42%) coronary vascular (159 ST-elevation myocardial infarction, 316 non-ST-elevation myocardial infarction, 218 unstable angina, 163 sudden cardiac death); 188 (9%) peripheral vascular (43 aortic, 53 embolic visceral or limb ischaemia, 92 critical limb ischaemia); and 62 unclassifiable deaths. Relative incidence of cerebrovascular events compared with coronary events was 1.19 (95% CI 1.06-1.33) overall; 1.40 (1.23-1.59) for non-fatal events; and 1.21 (1.04-1.41) if TIA and unstable angina were further excluded. Event and incidence rates rose steeply with age in all arterial territories, with 735 (80%) cerebrovascular, 623 (73%) coronary, and 147 (78%) peripheral vascular events in 12 886 (14%) individuals aged 65 years or older; and 503 (54%), 402 (47%), and 105 (56%), respectively, in the 5919 (6%) aged 75 years or older. Although case-fatality rates increased with age, 736 (47%) of 1561 non-fatal events occurred at age 75 years or older. INTERPRETATION: The high rates of acute vascular events outside the coronary arterial territory and the steep rise in event rates with age in all territories have implications for prevention strategies, clinical trial design, and the targeting of funds for service provision and research.
BACKGROUND: Distal protection devices are increasingly used to prevent embolization during percutaneous coronary interventions (PCI) in saphenous vein grafts (SVG) and native coronary arteries (NV). During interventions with the Filterwire device we have observed reduced flow that is reversible following removal of the filter (filter no reflow, FNR), which might be erroneously interpreted as true no reflow and might be associated with reduced capture efficiency of the basket. METHODS: We analyzed the incidence of FNR in 58 patients (60 lesions) at high risk of embolization undergoing PCI of either a SVG or a NV using the Filterwire (Boston Scientific, Natick, MA). Qualitative and quantitative angiographic analysis was performed, and the volume of collected debris was estimated using a photographic technique. RESULTS: In our population, about 1/3 of the cases showed FNR, which was associated with angiographically visible filling defects within the basket, indicating macroembolism. However some patients (especially those undergoing vein graft interventions) showed filling defects without FNR, and some others FNR without filling defects. Thus we tried to understand the predictors of FNR: FNR was associated with higher amount of collected debris (36.97 +/- 42.98 mm(3) vs. 11.31 +/- 18.47 mm(3), p = 0.005), was neither prevented by abciximab, nor predicted by high thrombotic burden, increasing stent volume or need for predilatation. When patient with and without angiographically evident macroembolisation were separately analyzed, a linear correlation of FNR with the quantity of debris was only apparent in the macroembolization group. CONCLUSIONS: Interventionalists should be aware of the "Filter No Reflow", a common but reversible angiographic complication when the Filterwire device is used. Reduced flow seen during these procedures should be treated conservatively. Mechanical obstruction of the filter, but also other mechanisms (pharmacologically active debris? platelet aggregates?) play a role in this phenomenon.
AIMS: To assess transthoracic echocardiography (TTE) using second harmonic imaging with Valsalva manoeuvre compared to transesophageal echocardiography (TEE) for the diagnosis of right to left cardiac and pulmonary shunts. METHODS AND RESULTS: One hundred and ten patients referred for TEE underwent TTE with bubble contrast. Bubbles in the left atrium within three cardiac cycles were considered diagnostic for a patent foramen ovale (PFO) and later as a pulmonary shunt. Greater than 20 bubbles in the left atrium was considered a large shunt and less than 20 a small shunt. TEE was performed immediately afterwards and read blinded to the TTE results. Pick-up rates were similar with 19 TEE positive (13 PFO) and 18 TTE positive (14 PFO) patients. There were five TEE positive/TTE negative cases who had significantly poorer TTE image quality score (2.7 +/- 0.8 vs 1.9 +/- 0.6, p < 0.05). There were six TEE negative/TTE positive cases, two cases requiring Valsalva manoeuvre to become positive. The Valsalva manoeuvre significantly increased the number of bubbles shunting (10 +/- 11 vs 20 +/- 19, p < 0.005). CONCLUSION: TTE with Valsalva manoeuvre is as good as TEE in diagnosing shunts. Valsalva manoeuvre increases the size of shunt. Both techniques produce false negative results.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: The "warm up" effect in angina may represent ischaemic preconditioning, which is mediated by adenosine A(1) receptors in most models. OBJECTIVE: To investigate the effect of a selective A(1) agonist, GR79236 (GlaxoSmithKline), on exercise induced angina and ischaemic left ventricular dysfunction in patients with coronary artery disease. DESIGN: A double blind crossover study. PATIENTS: 25 patients with multivessel coronary artery disease. INTERVENTIONS: On mornings one week apart, patients received intravenous GR79236 10 microgram/kg or placebo, and then carried out two supine bicycle exercise tests separated by 30 minutes. Equilibrium radionuclide angiography was done before and during exercise. RESULTS: The onset of chest pain or 1 mm ST depression was delayed and occurred at a higher rate-pressure product during the second exercise test following either placebo or GR79236. Compared with placebo, GR79236 did not affect these indices during equivalent tests. GR79236 reduced resting global ejection fraction from (mean (SD)) 63 (7)% to 61 (5)% (p < 0.05) by a selective reduction in the regional ejection fraction of "ischaemic" left ventricular sectors (those where the ejection fraction fell during the first exercise test following placebo). Ischaemic sectors showed increased function during the second test following placebo (72 (21)% v 66 (20)%; p = 0.0001), or during the first test following GR79236 (69 (21)% v 66 (20)%; p = 0.0001). Sequential exercise further increased the function of ischaemic sectors even after drug administration. CONCLUSIONS: GR79236 failed to mimic the warm up effect, and warm up occurred even in the presence of this agent. This suggests that ischaemic preconditioning is not an important component of this type of protection. The complex actions of the drug on regional left ventricular function at rest and during exercise suggest several competing A(1) mediated actions.
Explore the source record for details and available documents.