PubMed Health⌕ Search

Biomedical subjects

A P F Turner

Publications and source records attributed to A P F Turner.

7 recordsLinked to original sources

Molecularly imprinted polymers for the recognition of proteins: the state of the art.

Molecular imprinting has proved to be an effective technique for the creation of recognition sites on a polymer scaffold. Protein imprinting has been a focus for many chemists working in the area of molecular recognition, since the creation of synthetic polymers that can specifically recognise proteins is a very challenging but potentially extremely rewarding objective. It is expected that molecularly imprinted polymers (MIPs) with specificity for proteins will find application in medicine, diagnostics, proteomics, environmental analysis, sensors and drug delivery. In this review, the authors provide an overview of the progress achieved in the decade between 1994 and 2005, with respect to the challenging area of MIPs for protein recognition. The discussion furnishes a comparative analysis of different approaches developed, underlining their relative advantages and disadvantages and highlighting trends and possible future directions.

Adsorption↗

A novel optical biosensor format for the detection of clinically relevant TP53 mutations.

The TP53 gene has been the subject of intense research since the realisation that inactivation of this gene is common to most cancer types. Numerous publications have linked TP53 mutations in general or at specific locations to patient prognosis and therapy response. The findings of many studies using general approaches such as immunohistochemistry or sequencing are contradictory. However, the detection of specific mutations, especially those occurring in the structurally important L2 and L3 zinc binding domains, which are the most common sites of TP53 mutations, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. In this study, the TI-SPR-1 surface plasmon resonance system and Texas Instruments Spreeta chips were used to develop a DNA biosensor based on thiolated probes complementary to these domains. The sensors were able to detect these mutations in both oligonucleotides and PCR products with normal and mutant TP53 DNA, but the difference in hybridisation signal was small. Preliminary experiments to enhance the signal using Escherichia coli mismatch repair proteins, MutS and single strand binding protein were carried out. It was found that MutS was unable to bind to mismatch oligonucleotides, but single strand binding protein was able to bind to single stranded probes, which had not hybridised to the target, resulting in a three-fold increase in the sensitivity of the biosensor. While further work needs to be carried out to optimise the system, these preliminary experiments indicate that the TI-SPR-1 can be used for the detection of clinically relevant mutations in the TP53 gene and that the sensitivity can be increased significantly using single strand binding protein. This system has a number of advantages over current mutation detection technologies, including lower cost, ease of sensor preparation and measurement procedures, technical simplicity and increased speed due to the lack of need for gel electrophoresis.

Biosensing Techniques↗

Detection of TP53 mutation using a portable surface plasmon resonance DNA-based biosensor.

A DNA-based surface plasmon resonance (SPR) biosensor has been developed for the detection of TP53 mutation using the inexpensive and commercially available instrument, SPREETA SPR-EVM-BT, from Texas Instruments. A direct immobilisation procedure, based on the coupling of thiol-derivatised oligonucleotide probes (Probe-C6-SH) to bare gold sensor surfaces, was optimized using synthetic oligonucleotides. Hybridisation reactions between the immobilised probe and a short sequence (26 mer) complementary, non-complementary and one-point mutation DNA were then investigated. The main analytical parameters of the sensor system were studied in detail including selectivity, sensitivity, reproducibility and analysis time. Finally, the sensor system was successfully applied to polymerase chain reaction (PCR)-amplified real samples, DNA extracted from both normal, wild-type, (Jurkat) and mutated (Molt 4), carrying the mutation at codon 248 of the TP53 cell lines. The results obtained demonstrate that the DNA-based SPR biosensor was able to distinguish sequences present in the various samples that differ only by one base; and hence, it appears to be a strong candidate technique for the detection of gene mutation.

Biosensing Techniques↗

Surface plasmon resonance sensor for domoic acid based on grafted imprinted polymer.

A molecularly imprinted polymer (MIP) film for domoic acid (DA) was synthesised by direct photo-grafting onto a gold chip suitable for a surface plasmon resonance (SPR) based bioanalytical instrument system, the BIAcore 3000. The gold surface was first functionalised with a self-assembled monolayer of 2-mercaptoethylamine and subsequent carbodiimide chemistry was performed for covalent attachment of the photoinitiator, 4,4'-azobis(cyanovaleric acid). This ensured that the formation of the MIP thin film, comprising 2-(diethylamino) ethyl methacrylate as functional monomer and ethylene glycol dimethacrylate as cross-linker, occurred only at the surface level. Optimisation and control over the grafting procedure were achieved using contact angle measurements and atomic force microscope (AFM) imaging. The surface grafting resulted in the formation of thin and homogeneous MIP film with thickness of 40 nm. A competitive binding assay was performed with free DA and its conjugate with horseradish peroxidase, which was used as a refractive label. The sensor was evaluated for its sensitivity, cross-reactivity, and robustness by using a BIAcore 3000. Likewise, monoclonal antibodies acting as natural receptors for the toxin were studied with the same BIAcore system. Results of a comparison between the artificial and natural receptors are reported. In contrast to monoclonal antibodies, the regeneration of MIP chip did not affect its recognition properties and continuous measurement was possible over a period of at least 2 months.

Biosensing Techniques↗

MIP-based solid phase extraction cartridges combined with MIP-based sensors for the detection of microcystin-LR.

Microsystin-LR is one of the most widespread and dangerous toxins produced by the freshwater Cyanobacteria. The contamination of water supplies with microcystin-LR has been reported in several areas around the world and the development of an easy-to-use, rapid, robust and inexpensive sensor for this toxin is urgently required. In this work an artificial receptor for microcystin-LR was synthesised using the technique of molecular imprinting. The composition of the molecularly imprinted polymer (MIP) was optimised using computer modelling. The synthesised polymer was used both as a material for solid-phase extraction (SPE) and as a sensing element in a piezoelectric sensor. Using the combination of SPE followed by detection with a piezoelectric sensor the minimum detectable amount of toxin was 0.35 nM. The use of MIP-SPE provided up to 1000 fold pre-concentration, which was more than sufficient for achieving the required detection limit for microcystin-LR in drinking water (1 nM). This work is the first example where the same MIP receptor has been used successfully for both SPE and the corresponding sensor.

Adsorption↗

Improved procedures for immobilisation of oligonucleotides on gold-coated piezoelectric quartz crystals.

The high sensitivity and specificity of DNA hybridisation techniques makes them powerful tools for environmental or clinical analysis. This work describes the development of a DNA piezoelectric biosensor for the detection of the hybridisation reaction. Attention was focused on the choice of the coating chemistry that could be used for the immobilisation of oligonucleotides onto the gold surface of the quartz crystal. Four immobilisation procedures were tested and compared considering the amount of immobilised probe, the extent of the hybridisation reaction, the possibility of regeneration and the absence of non-specific adsorption. All the experiments were performed with oligonucleotides of 25 bases (probe, target and non-complementary oligonucleotide). The four coating methods were all based on the use of self-assembled monolayers (SAM). Three of them employed the interaction between streptavidin and biotin for the immobilisation of a biotinylated probe. Results indicated that immobilisation of a biotinylated probe on streptavidin linked to a layer of carboxylated dextran provides higher sensitivity for the detection of the hybridisation reaction, absence of non-specific adsorption and a higher stability with respect to the regeneration step.

Apolipoproteins E↗

Recognition of anaerobic bacterial isolates in vitro using electronic nose technology.

AIMS: Use of an electronic nose (e.nose) system to differentiation between anaerobic bacteria grown in vitro on agar media. METHODS AND RESULTS: Cultures of Clostridium spp. (14 strains) and Bacteroides fragilis (12 strains) were grown on blood agar plates and incubated in sampling bags for 30 min before head space analysis of the volatiles. Qualitative analyses of the volatile production patterns was carried out using an e.nose system with 14 conducting polymer sensors. Using data analysis techniques such as principal components analysis (PCA), genetic algorithms and neural networks it was possible to differentiate between agar blanks and individual species which accounted for all the data. A total of eight unknowns were correctly discriminated into the bacterial groups. CONCLUSIONS: This is the first report of in vitro complex volatile pattern recognition and differentiation of anaerobic pathogens. SIGNIFICANCE AND IMPACT OF THE STUDY: These results suggest the potential for application of e.nose technology in early diagnosis of microbial pathogens of medical importance.

Bacteria, Anaerobic↗