The depth of microembolic signal direction change corresponds with vessel anatomy.

BACKGROUND: Analysis of microembolic signals (MES) suggests a change of flow direction (CFD). The aim of the present study was to relate MES direction in an amplitude plot, based on the radiofrequent (RF) signal, to the vascular anatomy as seen with transcranial color-coded duplex (TCCD). METHODS: In 5 patients undergoing heart valve surgery or aortic arch replacement, preoperatively TCCD of the distal part of the internal carotid artery and the middle and anterior cerebral arteries on the right side was performed to determine potential depths of changes in flow direction. Peroperatively, a transcranial pulsed Doppler (TCD) monitoring probe was fixed over the right temporal bone. A customized RF-based system, connected to the TCD device, captured and stored the MES. Off-line, the color-coded amplitude of the clutter-filtered RF signals was plotted as a function of time (sample interval 0.17 ms) and depth (sample interval 0.05 mm). RESULTS: A total of 313 MES were recorded in 4 patients with 66 MES (21%) showing a CFD. All MES with CFD could be assigned to maximally three different depth values, six out of eight CFD depth values as seen with the RF analysis were within 1 mm from a turn in flow direction as estimated with TCCD. CONCLUSIONS: A CFD of MES occurred at a very limited number of depths and corresponded mostly with the intracranial vascular anatomy, namely a turn of the flow direction in the intracranial vessels as observed with TCCD.

Carotid Artery, Internal↗

Systemic dilation diathesis in patients with abdominal aortic aneurysms: a role for matrix metalloproteinase-9?

INTRODUCTION: Accumulating evidence suggests that patients with abdominal aortic aneurysm (AAA) suffer from a systemic dilating condition affecting all arteries. Matrix metalloproteinases (MMPs) and their natural inhibitors, the tissue inhibitors of metalloproteinases (TIMPs), appear to be involved in aneurysm formation, as evidenced by increased aortic tissue MMP activity and plasma MMP levels in patients with AAA. Hypothesizing that an imbalance in plasma MMP/TIMP level might be associated with a systemic dilation diathesis, we studied mechanical vessel wall properties of non-affected arteries of patients with either AAA or aorto-iliac obstructive lesions in association with plasma MMP-9 and TIMP-1 levels. METHODS: Twenty-two patients with AAA and 12 with aorto-iliac occlusive disease (AOD) were included. Diastolic diameter (d) and distension (Deltad) were measured at the level of the common carotid artery (CCA) and suprarenal aorta (SA) using ultrasonography. Distensibility (DC) and compliance (CC) were calculated from d, Deltad and brachial pulse pressure. Plasma MMP-9 and TIMP-1 were determined with specific immunoassays. RESULTS: The average (+/-SD) age was 72.3+/-5.6 and 65.0+/-8.2 years for the AAA and AOD patients, respectively, (P=0.005). CCA diameter was 9.1+/-1.3mm in AAA patients and AOD 7.8+/-1.4mm in AOD patients, P=0.009. This difference persisted after correction for age. Plasma MMP-9 and TIMP-1 did not differ significantly between AAA and AOD patients. In the total 34 patients, the MMP-9/TIMP-1 ratio was correlated inversely with distensibility (r=-0.74, P=0.002) and to compliance (r=-0.58, P=0.024) of the suprarenal aorta. CONCLUSIONS: The CCA diameter was larger in AAA patients compared to AOD patients. MMP-9/TIMP-1 ratio was associated with decreased distensibility and compliance of the suprarenal aorta. These data support the idea that AAA patients exhibit a systemic dilation diathesis, which might be attributable to MMP/TIMP imbalances.

Aged↗

Arterial elastic properties and cardiovascular risk/event.

Cardiovascular disease is a major cause of morbidity and mortality in the western world. There is convincing evidence that the elastic properties, particularly of large arteries, are impaired in the presence of cardiovascular disease and risk factors such as cigarette smoking, hypertension, diabetes and ageing. Evidence is also emerging that treatment of these risk factors is associated with an improvement in the elastic properties, mirrored by a reduction in the cardiovascular risk and events. The main problems associated with arterial elasticity are the multiple definitions and methods of measurement and the problem of obtaining reliable nearby blood pressure measurement. Nevertheless, duplex estimation appears to be a non-invasive, accurate and reliable method of defining these properties. This method is broadly used as a research tool, but there is a good case for its use in clinical practice, particularly in the screening of patients at risk of cardiovascular events.

Age Factors↗

Wall shear stress assessment in the common carotid artery of end-stage renal failure patients.

Under physiological circumstances in the common carotid artery (CCA), mean wall shear stress (WSS), defined as mean wall shear rate (WSR) times local whole blood viscosity (WBV), is maintained at approximately 1.5 Pa. In patients with end-stage renal failure (ESRF) whole blood viscosity is low and it is not unlikely that mean WSS is lower in these patients than in control subjects. Moreover, hemodialysis causes an acute increase in blood viscosity with possible effects on WSS. In this study WSS in the CCA was determined with the Shear Rate Estimating System, an apparatus based on ultrasound, in ESRF patients (n = 13) and in presumed healthy age- and sex-matched control subjects (n = 13). Prior to hemodialysis, mean WSS (0.67 +/- 0.23 Pa) was significantly lower (p < 0.05) in patients with ESRF, due to both a lower WBV (2.80 +/- 0.52 mPa.s) and mean WSR (271 +/- 109 s(-1)), than in the control subjects (mean WSS: 1.24 +/- 0.20 Pa; WBV: 3.20 +/- 0.29 mPa.s; WSR: 387 +/- 51 s(-1)). Hemodialysis induced an increase in WBV (up to 3.71 +/- 1.54 mPa.s, p < 0.01), but mean WSS did not change significantly due to a reciprocal decrease in mean wall shear rate. These findings demonstrate that WSS is lower in hemodialysis patients than in control subjects, and that mean WSS is maintained at this low level despite an acute change in blood viscosity.

Adult↗

The effect of chronic flow changes on brachial artery diameter and shear stress in arteriovenous fistulas for hemodialysis.

BACKGROUND: Vessel wall adaptation to acute or chronic flow changes is regulated by shear stress (SS) at the endothelium. This hypothesis was tested in the brachial artery (BA) of patients receiving an arteriovenous fistula (AVF) for hemodialysis vascular access. METHODS: The acute and sustained effects were evaluated in 13 patients. Pre-operatively and postoperatively on predetermined time-points BA diameter and shear rate (SR) were measured. SS was calculated from whole blood viscosity and SR. Analysis was performed with Wilcoxon's test and ANCOVA multivariate analysis. RESULTS: Acutely, mean SS increased (475%, p<0.05), peak-to-peak SS decreased (37%, p<0.05) and peak SS remained constant. BA diameter increased (15%, p<0.05). After one year a further increase was observed (r=0.59, p<0.001), plus an increase in mean SS (r=0.78, p<0.001). Peak-to-peak SS remained constant. CONCLUSION: Our results indicate that after AVF placement an acute increase in SS results in an acute increase of vessel diameter. However, one year of sustained high blood flow does not result in restoration of mean SS.

Arteriovenous Shunt, Surgical↗

Microembolic signal description: a reappraisal based on a customized digital postprocessing system.

The high variability in presence and signature of microembolic signals (MES), detected with transcranial Doppler sonography (TCD) in the middle cerebral artery (MCA), cannot be explained with the currently available published data. We applied customized postprocessing on the radiofrequency (RF) signal of a standard TCD system. The spatial resolution was on the order of 2 mm, depending only on the length of the ultrasound (US) burst emitted. The amplitude of clutter-filtered RF signals was color-coded and plotted as a function of time and depth (range 30 mm). Additionally, 128 point fast Fourier transforms (FFTs) (50% temporal overlap) were calculated, visualizing both the background Doppler spectrum and the MES. We evaluated 122 gaseous MES from two patients during cardiac surgery and 52 particulate MES from four patients after carotid endarterectomy. Both MES categories showed comparable properties: they appeared in the RF amplitude plot as rather straight lines of increased intensity, indicating that the velocity remained approximately the same while they passed the US beam. The velocity calculated from the amplitude plot never exceeded that of the background Doppler spectrum. Various "MES patterns" could be identified with respect to the depth range at which the MES were visible. A quarter of the gaseous MES changed their direction at a specific depth, suggesting that the MES entered a branch (e.g., an M2 artery or the anterior cerebral artery). In the FFT analysis, these MES contained both positive and negative frequencies. It is concluded that MES show consistent signature patterns in the amplitude-time plots and that the previously reported variability of MES appearance in conventional Doppler systems is an artefact caused by relatively large signal amplitudes and sample volumes.

Artifacts↗