Design of applicators for a 27 MHz multielectrode current source interstitial hyperthermia system; impedance matching and effective power.

In interstitial heating one of the main requirements for achieving a certain elevated temperature in a tumour is that the effective power per applicator (Peff), i.e. the power which is actually deposited in the tissue, is sufficiently high. In this paper this requirement is discussed for the applicators of the 27 MHz multielectrode current source (MECS) interstitial hyperthermia (IHT) system. To minimize power reflection, the applicator impedance was matched with the generator impedance by adjusting the length of the coaxial cable in between. Transmission line losses, applicator efficiency and subsequently Peff were computed for several applicator types. The actual Peff per electrode was obtained from calorimetric measurements. Experiments with RC loads, which can be seen as perfect applicators, were performed to investigate the effect of mismatching on Peff. Applicator losses were measured for clinically used applicators, both single- and dual-electrode, utilizing saline phantoms. A simple spherical tumour model, using the effective heat conductivity (keff) to account for heat transport, was used to estimate Peff for a given tumour size, implant size and applicator density. Computations of Peff of various MECS-IHT electrodes were in close agreement with the phantom measurements. Most of the initial generator power was absorbed in the transmission line (60-65%). The efficiency of the applicators was about 65%. For both single- and dual-electrode applicators the effective electrode power was found to be about 1 W. Model calculations show that Peff of 1 W is sufficient to reach a minimum tumour temperature of 43 degrees C in well perfused tumours (keff = 3 W m-1 degree C-1), using a typical implant with 2 cm electrodes and 1.5 cm spacing. Mismatching can considerably affect Peff. Both a reduction to almost zero and a two-fold increase are possible. However, because the matching theory is well understood, mismatching is not a serious problem in clinical practice and can even be used to increase Peff if necessary. We conclude that the applicator design and the impedance matching method chosen in the MECS system allow heating to temperatures in the therapeutic range with implants used in clinical practice.

Biophysical Phenomena↗

A 27 MHz current source interstitial hyperthermia system for small animals.

Temperature distribution is an important factor in thermo-radiotherapy and it is greatly dependent on the applied heating technique. Consistency of the heating method is therefore important in translating in vivo experimental data to the clinical situation. To further evaluate the combination of interstitial hyperthermia and interstitial radiotherapy, an experimental interstitial hyperthermia system has been developed for small (500-2000 mm3) tumours growing in the flank of a rat. The system used reproduces the properties of our clinical current source interstitial hyperthermia system. The heating system consists of four applicators, each with independent tuning and power control. The applicators are situated inside plastic afterloading catheters and are capacitively coupled with the surrounding tissue. The tumour is heated through dissipation of a 27 MHz current flowing to an external ground plane. An effective RF-filter allows reliable thermocouple temperature measurements when the power is switched on. The tumour temperature is easily controlled by means of a continuous temperature read-out and a clear temperature display. A minimum temperature up to 46 degrees C can be reached within 4-10 min and maintained (+/-0.5 degrees C) throughout the treatment period. Modelling calculations performed for this heating system indicate that the applicator temperatures should be kept equal in order to minimize the difference between maximum and minimum temperature. Significantly higher applicator currents are needed at larger distances from the ground plane. In addition, the homogeneity of the temperature distribution is improved when either the tumour is isolated or when the environmental temperature is increased. The calculations also show that temperature distribution is strongly dependent on effective heat conductivity. A description of the system and its performance is presented.

Animals↗