GafChromic RTQA film for routine quality assurance of high-energy photon beams.

Self-developing film offers many advantages over conventional radiographic verification film for routine radiotherapy quality assurance (QA). This paper presents results from an initial evaluation of a beam measurement system using GafChromic RTQA film and a flatbed scanner. Variability and energy dependence of the film calibration and accuracy of scanner readout are investigated in the context of QA measurements. For exposures of film between 2 and 4 Gy, the system is adequate for measurement of beam dimensions, as in multi-leaf collimator (MLC) offsets and secondary jaw calibrations, where agreement with conventional film measurements is within 0.5 mm. However, the measurement of absolute dose is subject to errors of about 25 cGy.

Calibration↗

Measurement of the three-dimensional distribution of radiation dose in grid therapy.

A single large dose of megavoltage x-rays delivered through a grid is currently being utilized by some centres for palliative radiotherapy treatments of large tumours. In this note, we investigate the dosimetry of grid therapy using two-dimensional film dosimetry and three-dimensional gel dosimetry. It is shown that the radiation dose is attenuated more rapidly with depth in a grid field than an open field, and that even shielded regions receive approximately 25% of the dose to the unshielded areas.

Dose Fractionation, Radiation↗

The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient's radiation therapy dose distribution. A 69-year-old male patient presented with a squamous cell carcinoma extending approximately 180 degrees across the top of the scalp (anterior to posterior) and from just over midline to 90 degrees left of the skull. The patient's treatment was commenced using two electron fields. For gel dosimetry, phantoms were produced in which the outer surface spatially corresponded to the outer contours of the patient's anatomy in the region of irradiation. The phantoms were treated with either electrons or intensity modulated radiation therapy (IMRT) with photons. The results identified a hot spot between the matched electron fields and confirmed the more homogeneous dose distribution produced by the IMRT planning system. The IMRT plan was then clinically implemented. The application of a clinical dose to a phantom shaped to a specific patient as well as the ability to select a slice at will during phantom imaging means that gel dosimetry can no longer be considered to simply have potential alone, but is now in fact a useful dosimetric tool.

Aged↗

Commissioning and quality assurance of the Pinnacle(3) radiotherapy treatment planning system for external beam photons.

The commissioning of a Pinnacle(3) treatment planning system is described. Four Elekta linear accelerators were commissioned for external beam photons. Measured data were used to derive parameter values for the Pinnacle(3) beam model by (1). fitting a Monte Carlo model of the accelerator head to measured data and then extracting the parameters for the Pinnacle(3) beam model, and by (2). using the auto-modelling facility within Pinnacle(3). Both of these methods yielded dose distributions in accord with published recommendations. A separate small-field beam model, customized for an in-house compact blocking system, was also created, which satisfied appropriate acceptance criteria for stereotactically guided conformal brain treatments. Inhomogeneous, oblique, asymmetrical and irregular fields were also assessed, with calculated and measured doses agreeing to within +/-3%. Dose-volume histogram calculation was found to be accurate to within +/-5% dose or volume for a grid size of 4 mm x 4 mm x 4 mm, with better accuracy being achieved for finer grids. Isocentric doses were compared between Pinnacle(3)'s collapsed cone convolution algorithm and the Bentley-Milan algorithm within the Target-2 treatment planning system. Dose differences were generally less than 3% in the dose prescribed, with larger values for breast plans, where the Pinnacle(3) algorithm calculated scatter more accurately. Pelvic and thoracic plans were also verified using an anthropomorphic phantom, with local dose differences between calculated and delivered dose of up to 8%, but mainly less than 3%, and with no systematic difference. Ionization chamber verifications using START and RT-01 trial procedures demonstrated differences between calculated and measured doses of less than 2%. Following satisfactory performance in the commissioning process, Pinnacle(3) has now been introduced into routine clinical use.

Algorithms↗

High precision focused irradiation in the form of fractionated stereotactic conformal radiotherapy (SCRT) for benign meningiomas predominantly in the skull base location.

OBJECTIVE: To present early clinical results of stereotactic conformal radiotherapy (SCRT) in patients with benign predominantly skull base meningiomas. MATERIAL AND METHODS: Between August 1994 and August 1999, 41 patients with benign residual or recurrent meningiomas were treated with SCRT. Thirty-three were histologically verified. All patients were immobilized in a GTC stereotactic relocatable frame, and underwent a post-contrast CT localization scan with additional MRI for fusion in 15 patients. Treatment was delivered on a 6 MV linear accelerator using three (12 patients), or 4 (29 patients) non-coplanar conformal fixed fields to doses of 50-55 Gy in 30-33 daily fractions. Tumours were relatively large with a median gross tumour volume (GTV) of 17.9 cm3 (range 2.5-183 cm3). RESULTS: At a median follow-up of 21 months (range 6-62 months) none of 41 patients have recurred. The current imaging tumour control rate is 100% at 1 and 3 years. The actuarial survival at 2 years is 100% and 91% at 3 and 5 years. Following SCRT tumour decreased in size in 9 patients. SCRT was well tolerated. Five patients had improvement in vision, and six patients improvement in cranial nerve function. Two patients whose planning target volume (PTV) included the sella developed hypopituitarism during and at 18 months after SCRT. One patient with pre-existing hydrocephalus due to pineal region meningioma developed cognitive impairment 7 months after treatment. One patient with involvement of the optic nerve had visual deterioration at 18 months. CONCLUSIONS: SCRT is a feasible high precision irradiation technique for residual and recurrent skull base meningiomas including both small and larger tumours with excellent early tumour control and low toxicity. Longer follow-up is necessary to demonstrate sustained tumour control and low morbidity of such high precision localized method of fractionated irradiation.

Adult↗

A comparison of multileaf collimator with conformal blocks for the boost phase of dose-escalated conformal prostate radiotherapy.

A multileaf collimator (MLC) is compared with conformal blocks for delivering the boost phase of dose-escalated conformal prostate radiotherapy. When using conformal blocks, the volume of rectum irradiated to 90% (V90) is lower (1.4+/-1.3%, 1 SD) for a three-field plan with gantry angles 0 degree, 90 degrees, 270 degrees than for a six-field plan with gantry angles 50 degrees, 90 degrees, 130 degrees, 230 degrees, 270 degrees, 310 degrees (2.1 +/- 1.3%, P = 0.002). However, when using an MLC in which the leaves and wedge are oriented at right angles, V90 is higher (4.7 +/- 3.0%) for a three-field plan than for a six-field plan (2.7 +/- 1.6%, P=0.05). The larger increase in V90 for the three-field plan when changing from conformal blocks to MLC is mainly due to the limitation imposed upon the MLC orientation by the use of wedges.

Dose-Response Relationship, Radiation↗

Design and implementation of a system for treating paediatric patients with stereotactically-guided conformal radiotherapy.

BACKGROUND AND PURPOSE: Stereotactically-guided conformal radiotherapy (SCRT) allows the delivery of highly conformal dose distributions to localised brain tumours. This is of particular importance for children, whose often excellent long-term prognosis should be accompanied by low toxicity. The commercial immobilisation system in use at our hospital for adults was felt to be too heavy for children, and precluded the use of anaesthesia, which is sometimes required for paediatric patients. This paper therefore describes the design and implementation of a system for treating children with SCRT. This system needed to be well tolerated by patients, with good access for treating typical childhood malignancies. MATERIALS AND METHODS: A lightweight frame was developed for immobilisation, with a shell-based alternative for patients requiring general anaesthetic. Procedures were set up to introduce the patients to the frame system in order to maximise patient co-operation and comfort. Film measurements were made to assess the impact of the frame on transmission and surface dose. The reproducibility of the systems was assessed using electronic portal images. RESULTS: Both frame and shell systems are in clinical use. The frame weighs 0.6 kg and is well tolerated. It has a transmission of 92-96%, and fields which pass through it deliver surface doses of 58-82% of the dose at d(max), compared to 18% when no frame is present. However, the frame is constructed to maximise the availability of unobstructed beam directions. Reproducibility measurements for the frame showed a mean random error of 1.0+/-0.2mm in two dimensions (2D) and 1.4+/-0.7 mm in 3D. The mean systematic error in 3D was 2.2mm, and 90% of all overall 3D errors were less than 3.4mm. For the shell system, the mean 2D random error was 1.5+/-0.2mm. CONCLUSIONS: Two well-tolerated immobilisation devices have been developed for fractionated SCRT treatment of paediatric patients. A lightweight frame system gives a wide range of possible unobstructed beam directions, although beams that intersect the frame are not precluded, provided that output corrections are applied. A shell system allows the use of general anaesthesia. Both systems give reproducible immobilisation to complement the high-precision treatment delivery.

Brain Neoplasms↗

Stereotactic radiotherapy for solitary brain metastases.

PURPOSE: Surgery is considered to be the treatment of choice for patients with solitary brain metastases. We report a single-centre experience of stereotactic radiotherapy (SRT)/radiosurgery as an alternative to surgery and define prognostic parameters that provide for a more rational selection of patients for appropriate treatment. PATIENTS AND METHODS: Between 1990 and 1997, 96 patients with 106 brain metastases received SRT to a dose of 20 Gy in two fractions (range 20-30 Gy in 24 fractions) either alone or in combination with whole brain radiotherapy. RESULTS: After SRT, 51% of patients had improvement in neurological function. The median survival of the 96 patients was 9 months. The Radiation Therapy Oncology Group prognostic grouping for patients with multiple brain metastases (prognostic factors: age, performance status, systemic metastases, status of primary tumour) was applicable to this cohort, with median survivals of 15, 8 and 2 months for favourable, intermediate and poor prognostic groups respectively. CONCLUSION: SRT is a non-invasive method of treatment of solitary brain metastases and the outcome is comparable with the results obtained after surgical excision. Prognosis is determined by factors defined for patients with multiple brain metastases, with performance status being the most important. SRT/radiosurgery should be reserved for patients with favourable prognostic factors, with a Karnofsky performance status >70, who have a reasonable chance of good quality prolonged survival. In future trials, radiosurgery should be compared in terms of survival, quality of life and health economics to whole brain radiotherapy and surgery.

Adult↗

A Comparison of clinical target volumes determined by CT and MRI for the radiotherapy planning of base of skull meningiomas.

PURPOSE: To assess the utility of image registration and to compare the localization of clinical target volumes (CTV) using CT and MRI for patients with base of skull meningiomas undergoing radiotherapy. METHODS AND MATERIALS: Seven patients were imaged using CT and a T1-weighted MR volumetric sequence. Following image registration using a chamfer-matching algorithm, transaxial MR slices were reconstructed to match the planning CT slices. The accuracy of the image fusion was assessed in a preliminary study with matching accuracy better than 1.5 mm. The CTV in each patient was separately segmented by two independent observers for both CT and reconstructed MR image sets. Scalar and vector assessments were made of the difference in radial extent between the two outlines on each transaxial plane for all patients. A positive vector value corresponded to a greater extension of the tumor on MR compared to CT and vice versa. Scalar measurements compared the modulus of the differences between MR and CT, regardless of which volume was more extensive. Qualitative comparisons were also performed. RESULTS: Interobserver difference was small with a mean (+/- 1SD) volume difference of 1.5 +/- 1.5 cm(3) for CT and 0.5 +/- 1.0 cm(3) for MRI. The mean CT- and MR- CTVs were 17.6 +/-10.8 and 19.6 +/-14.2 cm(3) respectively. The mean overlap and composite volumes were 13.8 +/-10. 1 and 23.3 +/-14.8 cm(3) respectively. Average scalar differences in the left, right, anterior, and posterior directions were 6.0 +/- 7.0, 3.3 +/- 2.5, 4.9 +/- 3.9, and 4.5 +/- 5.0 mm respectively. The average vector differences were 3.3 +/- 8.5, -0.3 +/- 3.8, 1.1 +/- 5. 8, 1.5 +/- 6.4 mm (for left, right, anterior, and posterior directions respectively). Qualitatively, MR appeared to discern more tumor involvement in soft tissue regions adjacent to the skull base whereas CT appeared to provide larger target volumes within bony regions. CONCLUSIONS: MRI appeared to define CTVs that were larger but not inclusive of CT-defined CTVs. Although the average vector differences were small, the differences on individual borders could be large. In some instances, the CT or MR volumes were vastly different, each providing separate information. Therefore, the use of MRI and CT is complementary. Until accurate histological confirmation of disease extent is available, it is prudent to consider composite CT/MR volumes for the radiotherapy planning of base of skull meningiomas.

Adult↗

The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy.

The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precision-cast lead alloy shielding blocks. Each treatment was performed three times using phantoms and calibration gels manufactured in-house. Two phantoms were specially designed for this work to aid accurate positioning of the gels for irradiation and imaging. All gels were imaged post-irradiation using a Siemens Vision 1.5T MR scanner. T2 relaxation images were calibrated to absorbed dose distributions using a number of smaller calibration vessels to produce distribution maps of relative dose. The relative dose distributions were found to be reproducible, with the standard deviation on the mean areas enclosed by the > or = 50% isodose lines measured in three orthogonal planes being 6.4% and 4.1% for the coplanar and non-coplanar plans respectively. The measured distributions were also consistent with those planned, with isodose lines generally agreeing to within a few millimetres. However, the measured absolute doses were on average 23.5% higher than those planned. Although the polyacrylamide gel dosimetry technique has some limitations, particularly when calibrating distributions to absolute dose, the ability to resolve sharp dose gradients in three dimensions with millimetre precision is invaluable when verifying complex conformal treatment plans, where avoidance of proximal, critical structures is a treatment criterion.

Acrylic Resins↗

Stereotactic conformal radiotherapy for pituitary adenomas: technique and preliminary experience.

OBJECTIVE: Stereotactic conformal radiotherapy (SCRT) is a high precision technique of fractionated radiotherapy which ensures accurate delivery of radiation with reduction in the volume of normal tissue irradiated as compared to conventional external beam radiotherapy. We describe the technique and preliminary experience of SCRT in patients with residual and recurrent pituitary adenomas. PATIENTS AND METHODS: Between February 1995 and March 1999, 22 patients (mean age: 45.3, range: 20-67 years) with residual or recurrent pituitary adenomas (13 nonfunctioning, nine secretory) were treated with SCRT. All were immobilized in a relocatable Gill-Thomas-Cosman (GTC) frame and tumour was localized on a postcontrast planning computerized tomography (CT) and MRI scan. The gross tumour volume (GTV) and the critical structures were outlined on contiguous 2-3 mm separated slices. A margin of 5 mm (12 patients) to 10 mm (10 patients) was grown around GTV in three-dimensions (3-D) to generate the planning target volume (PTV). The treatment was delivered by three (five patients) and four (17 patients) maximally separated conformal fixed fields with each field conformed to the shape of the tumour using customized lead alloy blocks (19 patients) or multileaf collimator (three patients). The patients were treated on a 6-MV linear accelerator to a dose of 45 Gy in 25 fractions (18 patients) and 50 Gy in 30 fractions (four patients). RESULTS: The technique of SCRT has become a part of the routine work of the radiotherapy department. The treatment was well tolerated with minimal acute toxicity. One patient developed transient quadrantanopia 2 weeks after treatment with full recovery after a short course of corticosteroids. One patient had a transient visual deterioration 7 months after treatment due to cystic degeneration of the tumour which fully recovered following surgical decompression. Nine of the 15 patients presenting with visual impairment had improvement after treatment and the visual status remained stable in all others. One patient with acromegaly and one with a prolactinoma achieved normalization of elevated hormonal abnormality four and 10 months after SCRT, respectively. The remaining seven patients with a secretory adenoma had declining hormone levels at last follow-up. Newly initiated hormone replacement therapy was required in five patients. At a median follow-up of 9 months (range 1-44 months), the 1 and 2 year actuarial progression free and overall survival were 100%. CONCLUSION: Stereotactic conformal radiotherapy is a high precision technique suitable for the treatment of pituitary adenomas requiring radiotherapy. Preliminary results suggest effective tumour control and low toxicity within the range expected for conventional external beam radiotherapy. While the technique is of potential benefit in reducing the volume of normal brain irradiated, the advantages in terms of sustained tumour control and reduced toxicity over conventional radiotherapy need to be demonstrated in long-term prospective studies.

Adenoma↗

Optimization of stereotactically-guided conformal treatment planning of sellar and parasellar tumors, based on normal brain dose volume histograms.

PURPOSE: To investigate the optimal treatment plan for stereotactically-guided conformal radiotherapy (SCRT) of sellar and parasellar lesions, with respect to sparing normal brain tissue, in the context of routine treatment delivery, based on dose volume histogram analysis. METHODS AND MATERIALS: Computed tomography (CT) data sets for 8 patients with sellar- and parasellar-based tumors (6 pituitary adenomas and 2 meningiomas) have been used in this study. Treatment plans were prepared for 3-coplanar and 3-, 4-, 6-, and 30-noncoplanar-field arrangements to obtain 95% isodose coverage of the planning target volume (PTV) for each plan. Conformal shaping was achieved by customized blocks generated with the beams eye view (BEV) facility. Dose volume histograms (DVH) were calculated for the normal brain (excluding the PTV), and comparisons made for normal tissue sparing for all treatment plans at > or =80%, > or =60%, and > or =40% of the prescribed dose. RESULTS: The mean volume of normal brain receiving > or =80% and > or =60% of the prescribed dose decreased by 22.3% (range 14.8-35.1%, standard deviation sigma = 7.5%) and 47.6% (range 25.8-69.1%, sigma = 13.2%), respectively, with a 4-field noncoplanar technique when compared with a conventional 3-field coplanar technique. Adding 2 further fields, from 4-noncoplanar to 6-noncoplanar fields reduced the mean normal brain volume receiving > or =80% of the prescribed dose by a further 4.1% (range -6.5-11.8%, sigma = 6.4%), and the volume receiving > or =60% by 3.3% (range -5.5-12.2%, sigma = 5.4%), neither of which were statistically significant. Each case must be considered individually however, as a wide range is seen in the volume spared when increasing the number of fields from 4 to 6. Comparing the 4- and 6-field noncoplanar techniques to a 30-field conformal field approach (simulating a dynamic arc plan) revealed near-equivalent normal tissue sparing. CONCLUSION: Four to six widely spaced, fixed-conformal fields provide the optimum class solution for the treatment of sellar and parasellar lesions, both in terms of normal brain tissue sparing and providing a relatively straightforward patient setup. Increasing the number of fields did not result in further significant sparing, with no clear benefit from techniques approaching dynamic conformal radiotherapy in the cases examined.

Brain↗

Stereotactically guided conformal radiotherapy for meningiomas.

PURPOSE: Stereotactically guided conformal radiotherapy, (SCRT) is a high precision technique of conformal radiotherapy (RT) which reduces the volume of normal tissue irradiated compared to conventional RT and may lead to a reduction in long-term toxicity We describe the technique and the preliminary results in patients with inoperable, residual or recurrent meningiomas. MATERIAL AND METHODS: From July 1993 to November 1997, 24 patients (median age: 56 years, range: 28-72) with base of skull (n = 21). falx or upper skull (n = 3) meningiomas were treated with SCRT. The technique employed immobilization in a Gill-Thomas-Cosman (GTC) frame and CT localization with a Brown-Roberts-Wells (BRW) fiducial system for stereotactic space definition. The planning target volume (PTV) was defined as gross tumour volume (GTV) and a 0.5-1 cm margin. Treatment was delivered with three (12 patients) or four non-coplanar conformal fixed fields (12 patients) Conformal blocking was achieved either with lead alloy blocks (n = 11) or with a multi-leaf collimator (MLC) (n = 13). Patients were treated on a 6 MV linear accelerator to doses of 50-55 Gy, in 30-33 daily fractions. The treatments were carried out as part of a routine work of a busy radiotherapy department. RESULTS: Median GTV for 24 meningiomas was 21.7 cm3 (range: 4.4-183 cm3). SCRT was well tolerated with minimal toxicity Three months after the end of radiotherapy, seven of 15 patients with neurological deficit had an improvement and eight remained unchanged. Two patients experienced early side effects (one VII nerve palsy, one Addisonian state). At a median follow-up of 13-months (range: 3-43) the 1 year progression free survival and overall survival are 100%. which is within the range expected for conventional fractionated radiotherapy for meningiomas. CONCLUSIONS: SCRT is a feasible technique of high precision conformal RT for patients with meningiomas. Potential advantages in tumour control, survival and toxicity over conventional RT, require evaluation in long-term prospective studies.

Adult↗

Patient position reproducibility in fractionated stereotactic radiotherapy: an update after changing dental impression material.

The reproducibility of patient positioning within the Gill-Thomas-Cosman relocatable stereotactic frame was re-evaluated following the substitution of a new, softer, dental impression material for the original hard acrylic compound. The average total displacement for a series of 10 patients was 1.1 mm (+/- 0.6 mm). Rotational discrepancies were small. This technique cannot deliver accurate repositioning in the absence of patient co-operation.

Acrylic Resins↗

Comparison of a multi-leaf collimator with conformal blocks for the delivery of stereotactically guided conformal radiotherapy.

Stereotactically-guided conformal radiotherapy is a practical technique for irradiating irregular lesions in the brain. The shaping of the conformal fields may be achieved using lead alloy blocks, a conventional multi-leaf collimator (MLC) or a mini/micro-MLC. Although the former gives more precise shaping, it is labour intensive. The latter methods are more practical as both mould room and treatment room times are reduced, but the shaping is limited by the finite leaf-width. This study compares treatment plans, in terms of normal tissue doses and tumour coverage, for fields shaped using conformal blocks and a conventional MLC in two series of geometrical shapes and nine patient tumours. For the range of tumour sizes considered (volumes 14-264 cm3, minimum dimension 30 mm, maximum 102 mm), the MLC treats, on average, 14% (range 3-34%) and 17% (range 0-36%) more normal brain tissue than conformal blocks to >50% and >80% of the prescription dose, respectively. The large variability is due to strong dependence on tumour shape and the presence of partial leaf-widths in the MLC fit. It is therefore important to consider both of these effects when deciding whether the MLC is appropriate for a particular target volume.

Brain Neoplasms↗

An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry.

BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.

Acrylamide↗

Whole body doses from linear accelerator-based stereotactic radiotherapy.

PURPOSE: The objective of this work was to measure whole body radiation doses in a humanoid phantom from linear accelerator-based cranial stereotactic radiosurgery/therapy (SRS/T), using different beam arrangements. METHODS AND MATERIALS: A standard noncoplanar five-arc beam arrangement and a four-arc technique without a sagittal arc were used to deliver 20 Gy in a single fraction to a midline spherical target volume in the corpus callosum region of an Alderson-Rando anthropomorphic phantom using (i) a 20-mm and (ii) a 40-mm circular collimator. Whole body dose measurements were made using lithium fluoride thermoluminescent dosimetry. Whole body isodose plots in the sagittal and coronal planes and organ doses were compared for the two arcing beam arrangements. An ionization chamber was used to record the exit dose at intervals along the length of the phantom at midline and 4.5 cm off-axis for (i) a single fixed field and (ii) a solitary 90 degrees sagittal arc using a 40-mm circular collimator. RESULTS: The sagittal arc was the major contributor to neck and trunk doses when the five- and four-arc arrangements were compared, with fourfold greater thyroid dose. The gonad dose was increased by the sagittal arc, but was largely due to leakage radiation. The dose from a fixed field exiting down the long axis of the phantom was tenfold greater than that from a solitary 90 degrees sagittal arc. When the fixed field or arc traversed the lung or exited through the pharynx and major upper airways, the dose measurements below the diaphragm were 30-40% higher than those along the exit path of maximum soft tissue density. CONCLUSION: When SRS/T is used in nonmalignant conditions such as cranial arteriovenous malformations or benign tumors the exit paths of arcing beams or fixed fields should be taken into account when deciding upon the final treatment plan. Such consideration should minimize the risk of radiation-induced malignancy, notably in the thyroid gland of younger patients.

Particle Accelerators↗

Hypofractionated stereotactic radiotherapy in the management of recurrent glioma.

PURPOSE: This study aimed to assess the efficacy and toxicity of hypofractionated stereotactic radiotherapy (SRT) in the management of patients with recurrent glioma. METHODS AND MATERIALS: From January 1989 to July 1994, 36 patients with glioma were treated at the time of recurrence. Twenty-nine had recurrent high-grade astrocytoma, 3 high-grade oligodendroglioma, 1 high-grade ependymoma, and 3 pilocytic astrocytoma. Hypofractionated stereotactic radiotherapy was given using either three noncoplanar arcs or four to six noncoplanar fixed beams at 5 Gy/fraction, to doses ranging from 20 to 50 Gy initially on a dose escalation program. Two patients received 20 Gy, 8 received 30 Gy, 10 received 35 Gy, 10 received 40 Gy, 5 received 45 Gy, and 1 received 50 Gy, treating 5 days/week. RESULTS: The median survival of 29 patients with recurrent high-grade astrocytoma was 11 months from the time of SRT. This compared to a median survival of 7 months for a cohort matched for age, performance status, and initial histologic grade who received nitrosourea-based chemotherapy at recurrence (p < 0.05). Initial low-grade astrocytoma histology was the only favorable prognostic factor for survival on univariate analysis. Three patients with recurrent oligodendroglioma remain alive 11, 23, and 34 months after SRT. Three children treated for recurrent pilocytic astrocytoma remain alive 14, 41, and 55 months following SRT. Presumed radiation damage, defined as reversible steroid-dependent toxicity, was observed in 13 patients (36%) and required reoperation in 2 (6%). A total dose of >40 Gy was a major predictor of radiation damage (p < 0.005). CONCLUSION: Hypofractionated SRT is a noninvasive, well-tolerated, outpatient-based method of delivering palliative, high-dose, focal irradiation.

Adult↗