A P Zijdenbos

Publications and source records attributed to A P Zijdenbos.

5 recordsLinked to original sources

A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is available. Described as nonparametric nonuniform intensity normalization (N3), the method is independent of pulse sequence and insensitive to pathological data that might otherwise violate model assumptions. To eliminate the dependence of the field estimate on anatomy, an iterative approach is employed to estimate both the multiplicative bias field and the distribution of the true tissue intensities. The performance of this method is evaluated using both real and simulated MR data.

Brain↗

Design and construction of a realistic digital brain phantom.

After conception and implementation of any new medical image processing algorithm, validation is an important step to ensure that the procedure fulfills all requirements set forth at the initial design stage. Although the algorithm must be evaluated on real data, a comprehensive validation requires the additional use of simulated data since it is impossible to establish ground truth with in vivo data. Experiments with simulated data permit controlled evaluation over a wide range of conditions (e.g., different levels of noise, contrast, intensity artefacts, or geometric distortion). Such considerations have become increasingly important with the rapid growth of neuroimaging, i.e., computational analysis of brain structure and function using brain scanning methods such as positron emission tomography and magnetic resonance imaging. Since simple objects such as ellipsoids or parallelepipedes do not reflect the complexity of natural brain anatomy, we present the design and creation of a realistic, high-resolution, digital, volumetric phantom of the human brain. This three-dimensional digital brain phantom is made up of ten volumetric data sets that define the spatial distribution for different tissues (e.g., grey matter, white matter, muscle, skin, etc.), where voxel intensity is proportional to the fraction of tissue within the voxel. The digital brain phantom can be used to simulate tomographic images of the head. Since the contribution of each tissue type to each voxel in the brain phantom is known, it can be used as the gold standard to test analysis algorithms such as classification procedures which seek to identify the tissue "type" of each image voxel. Furthermore, since the same anatomical phantom may be used to drive simulators for different modalities, it is the ideal tool to test intermodality registration algorithms. The brain phantom and simulated MR images have been made publicly available on the Internet (http://www.bic.mni.mcgill.ca/brainweb).

Brain↗

Brain segmentation and white matter lesion detection in MR images.

This paper presents a review of methods and techniques that have been proposed for the segmentation of magnetic resonance (MR) images of the brain, with a special emphasis on the segmentation of white matter lesions. First, artifacts affecting MR images (noise, partial volume effect, and shading artifact) are reviewed and methods that have been proposed to correct for these artifacts are discussed. Next, a taxonomy of generic segmentation algorithms is presented, categorized as region-based, edge-based, and classification algorithms. For each category, the applications proposed in the literature are subdivided into 2-D, 3-D, or multimodal approaches. In each case, tables listing authors, bibliographic references, and methods used have been compiled and are presented. This description of segmentation algorithms is followed by a section on techniques proposed specifically for the analysis of white matter lesions. Finally, a section is dedicated to a review and a comparison of validation methods proposed to assess the accuracy and the reliability of the results obtained with various segmentation algorithms.

Algorithms↗

Developments towards the slice-wise three-dimensional reconstruction of the distribution of the contrast perfusion in the myocardial muscle from biplane angiographic views.

In theory, radiographic myocardial perfusion imaging allows a quantitative assessment of the functional significance of a coronary stenosis. However, in the conventional two-dimensional projection images there does not exist a one-two-one relationship between a selected myocardial region of interest (ROI) and one particular coronary segment perfusing that area due to over-projection of myocardial regions in front of and behind the selected ROI perfused by other arterial segments, which may result in measurements which are difficult to interpret or even unreliable. To overcome these problems, we have developed two algorithms to determine the spatial distribution of perfusion levels in slices of the heart, selected approximately perpendicular to the left ventricular long axis, from two orthogonal angiographic views: the Segmental Reconstruction Technique (SRT) and the Network Programming Reconstruction Technique (NPRT). Both techniques require a priori geometric information about the myocardium, which can be obtained from the epicardial coronary tree (epicardial boundaries) and the left ventricular lumen (endocardial boundaries). Using the SRT approach, pie-shaped segments are defined for each slice within the myocardial geometric constraints such that superimposition of these segments when projected in orthogonal biplane views is minimal. The reconstruction process uses a model with identical myocardial geometry and definition of segments. Each segment of the model is assigned a relative perfusion level with unit one if no other a priori information is available. In this case, the model contains geometric information only. In case a priori information about expected segmental perfusion levels is available, a level between zero and one is assigned to each segment. The a priori information on the myocardial perfusion levels can be extracted from either anatomic information about the location and severity of existing coronary arterial obstructions, or from a slice adjacent to the one under reconstruction. Using the NPRT approach perfusion levels are computed for each volume picture element of a slice within the reconstructed myocardial geometry, thus resulting in a much higher spatial resolution than the SRT approach. A priori information of perfusion levels must be included in this approach, again based upon anatomical information, or upon the slice adjacent to the one under reconstruction. The very first slice of a myocardial study will be reconstructed by the SRT approach. Extensive computer simulations for the SRT have proved that the mean difference between the actual and reconstructed segmental perfusion levels, on a scale from 0 to 1, is smaller than 0.45 (SEE = 0.0033, REE = 1.80) for various coronary artery disease states without the use of a priori information on expected perfusion levels. This error becomes smaller than 0.36 (SEE = 0.0026, REE = 1.42), if a priori information in the reconstruction technique is included. Similar computer simulations for the NPRT have proved that these mean differences in geometric segments equal to those defined for the SRT, are smaller than 2.94 (SEE = 0.0308, REE = 0.77) on a scale from 0 to 16, without the use of a priori information on expected perfusion levels, and smaller than 1.72 (SEE = 0.0304, REE = 1.10) on the same scale when a priori information is included. Therefore, it may be concluded that slice-wise three-dimensional reconstruction of perfusion levels is feasible from biplane computer-simulated data, and that a similarity exists for mean perfusion levels in corresponding regions in the simulated and reconstructed slices, for various states of single coronary artery disease.

Algorithms↗

Automatic detection of intracranial contours in MR images.

Segmentation of the intracranial cavity in medical images is valuable in several research areas such as the quantitative analysis of normal and abnormal brain tissues, the registration of different imaging modalities (MRI, PET, CT) based on surface models of the brain, and the rendering of volume data. Because the manual delineation of the brain contour in the images can be demanding and error prone, an automatic procedure to perform this task is desirable. We have developed and tested a robust method that permits the automatic detection of the intracranial contour in transverse MR images. The method is described and its performance evaluated.

Algorithms↗