PubMed Health⌕ Search

Biomedical subjects

A Panos

Publications and source records attributed to A Panos.

At least 19 recordsLinked to original sources

Dramatic post-cardiotomy outcome, due to severe anaphylactic reaction to protamine.

Immunologic reactions to protamine sulfate during cardiac surgery are very rare. The frequency and outcome of such adverse reactions is unclear. We report a case of lethal anaphylactic reaction to protamine that occurred in a non-diabetic patient following the uneventful replacement of the ascending aorta. We also briefly review the mechanisms of this adverse reaction and emit some considerations on the management of this situation.

Anaphylaxis↗

Influence of technique of coronary artery implantation on long-term results in composite aortic root replacement.

BACKGROUND: Long-term results after composite graft aortic root replacement may depend on the insertion technique. The aim of this study is to assess the influence of the technique of coronary artery implantation on long-term results in composite aortic root replacement. METHODS: One hundred fifty consecutive patients (mean age, 55 years; 119 men) with different disorders of the ascending aorta who underwent aortic root replacement with a composite graft prosthesis between January 1985 and December 1999 were retrospectively studied. Thirteen patients had previously undergone cardiovascular surgery. The open button technique was performed in 65 patients (43.3%, group 1) and the inclusion technique in 85 patients (56.7%, group 2). Mean follow-up was 70.5 months. Surgery was elective in 110 procedures (73%). RESULTS: Global actuarial survival was 76.1% +/- 4.3% for group 1 and 73.7% +/- 3.9% for group 2 at 10 years (p = 0.22). Freedom from reoperation excluding early deaths was 81% +/- 3% for group 1 and 86% +/- 2.2% for group 2 at 10 years (p = 0.62). Group 2 demonstrated a statistically significantly higher occurrence of pseudoaneurysm formation versus group 1 (p = 0.04). CONCLUSIONS: Composite graft aortic root replacement is a safe and effective therapy for proximal aortic aneurysm and dissection, resulting in good early and long-term results irrespective of the anastomotic technique. However, the open button technique seems to avoid late false aneurysm formation at the anastomotic sites.

Adolescent↗

Aortic valve replacement with the freestyle stentless bioprosthesis with respect to spacial orientation of patient coronary ostia.

OBJECTIVE: This study evaluates our results for safety and efficacy of aortic valve replacement using the Freestyle bioprosthesis (Medtronic, Inc, Minneapolis, Minn) with a new modified subcoronary implantation technique. This technique takes into account the spacial orientation of the stentless bioprosthesis in the aortic root with respect to the patient's coronary ostia rather than the native commissures. METHODS: Fifty-two consecutive patients with predominant aortic valve stenosis underwent aortic valve replacement with a Freestyle bioprosthesis by means of the described modified subcoronary technique over a 15-month period. Fifty of them were followed up by means of echocardiography at discharge, 6 months, and 1 year. There were 19 men and 31 women, with a mean age of 76 +/- 7 years (range, 58-87 years). Valve size ranged from 21 to 27 mm. RESULTS: Patients with bicuspid aortic valves had a significantly larger angle between both coronary ostia than patients with tricuspid aortic valves (P =.0001). The peak and mean systolic gradients decreased significantly during the first postoperative year for each valve size (P </=.001), and the effective valve areas increased significantly during this time interval for each valve size (P </=.01). Only 13 patients had aortic insufficiency at discharge, which was trivial in 9 and mild in 4 patients. The prevalence of trivial aortic insufficiency decreased during the first postoperative year, and that of mild aortic insufficiency remained unchanged. The sinotubular junction diameter was significantly greater than that of the aortic anulus for each valve size before operation (P <.001). The sinotubular junction diameter decreased significantly after aortic valve replacement and remained unchanged during the first postoperative year for each valve size (P <.001). CONCLUSIONS: Aortic valve replacement with the Freestyle bioprosthesis using the modified subcoronary technique, which takes into account the spacial orientation of the patient's coronary ostia, has hemodynamic results similar to those of other series with different subcoronary implantation techniques. This technique is reproducible, safe at the coronary ostial level, and effective in accommodating variability in angles between human coronary ostia, ranging from 130 degrees to 170 degrees. Moreover, the great preoperative discrepancies between aortic anulus and sinotubular junction diameters are corrected immediately after operation.

Aged↗

[High-risk PTCA assisted by the Hemopump 14F: the Geneva experience].

INTRODUCTION: The hemopump is a transvalvular, catheter-mounted, left ventricular assist device, intended for surgical placement via the femoral artery (hemopump 21 Fr. outer diameter). This device has demonstrated its ability to unload the left ventricle, leading to myocardial protection and haemodynamic stabilisation in patients with cardiogenic shock and those undergoing high-risk coronary angioplasty (PTCA). Since 1994, a new hemopump system (14 Fr. in external diameter, flow rates of 1.5-2.2 l/min) has been developed for percutaneous insertion. The aim of this study is to describe the immediate and mid-term results obtained during Hemopump 14 Fr. assisted high-risk PTCA. PATIENTS: Between September, 1993 and July, 1996, 8 males and 5 female patients (mean age 68.5 +/- 8.6 years) underwent Hemopump 14 Fr. supported high-risk PTCA. RESULTS: Mean duration of hemopump assistance was 108 +/- 62 min. Hemopump support on maximum speed led to an increase of cardiac index from 2.0 +/- 0.3 to 2.2 +/- 0.5 l/min (p = 0.04) and a decrease of pulmonary wedge pressure from 17 +/- 8 to 14 +/- 8 mm Hg (p = 0.004). LDH increased (463 +/- 305 to 558 +/- 237 u/l-p = 0.05) and the platelet count remained stable (192,840 +/- 60,904 to 190,230 +/- 56,492/mm3). Successful balloon angioplasty was performed in all patients. There was no hospital mortality. Three patients (23%) required blood transfusion. During follow-up, 1 patient (7.7%) developed femoral artery occlusion necessitating surgical repair, and 3 patients (23%) died from cardiac causes 3, 9 and 14 months after the procedure. CONCLUSIONS: The 14 Fr. Hemopump device may constitute a useful percutaneous mode of haemodynamic support for patients undergoing high-risk PTCA. The haemolysis it causes is mild and not clinically significant, but the hemopump is associated with a significant rate of local vascular complications. Recent improvements in interventional techniques and hardware have decreased the necessity for circulatory assistance during elective PTCA, even for very ill patients. Nevertheless, indications such as cardiogenic shock, the "bridge" period prior to heart transplantation and video-assisted minimally invasive cardiac surgery, or haemodynamic support of the right ventricle are the new applications of the hemopump.

Aged↗

Aorta-cutaneous fistula as a rare complication of localized chronic mediastinitis.

A 35-year-old man was admitted 5 years after congenital heart surgery complicated by Staphylococcus aureus and a cutaneous fistula located at the left fourth intercostal space. He was febrile (40 degrees C), suffering from sternal pain and suppuration from the old fistula. During examination arterial blood suddenly discharged from the fistula, so that surgery was immediately instituted. An infected Dacron tube implanting on the ascending aorta for a central aorto-pulmonary shunt was at the origin of a false aneurysm: this had led to the repeat formation of an aorta-cutaneous fistula and outbreak of external bleeding.

Adult↗

Left atrial myxoma presenting with myocardial infarction. Case report and review of the literature.

Coronary artery embolization is an extremely rare and potentially lethal complication of atrial myxomas. We present a case report and a literature review of this clinical association. A 53-year-old woman presented with an acute infero-lateral myocardial infarction. Coronary angiography performed 1 h after the onset of pain disclosed an abrupt stop and multiple embolization of the peripheral right coronary artery (RCA). A transthoracic echocardiographic study revealed the presence in the left atrium of an echogenic, mobile mass, compatible with myxoma. The tumour was successfully removed surgically 2 weeks later and the patient is doing well one year post operatively.

Coronary Angiography↗

Blunt injury to the supra-aortic arteries.

BACKGROUND: Blunt trauma causing injury to the vessels of the aortic arch is uncommon but may be attended by serious consequences. Most surgeons will experience only an occasional case and will need to rely on published literature for guidance. METHODS: A Medline search over 1986-1995 was carried out using the following keywords: brachiocephalic trunk, common carotid artery and subclavian artery; injury was used as a subheading. RESULTS AND CONCLUSION: After the aortic isthmus, the innominate is the most commonly injured artery in the chest. Whatever the site of an arterial lesion, however, angiography is the diagnostic test of choice. Some vascular lesions are relatively benign and may be managed without operation; this form of management may also be appropriate if there is severe associated neurological injury. Otherwise, operation using an approach and technique suited to the site of the injury is advocated.

Aorta, Thoracic↗

Mitral valve repair in lupus valvulitis--report of a case and review of the literature.

Valvulitis in systemic lupus erythematosus has been observed for many years. Fourteen cases of mitral valve replacement have been reported so far in the literature. In the light of all previously reported experiences, prosthetic valve related morbidity and mortality remain high in patients with systemic lupus erythematosus. We describe the first true instance of reconstructive approach in a patient who presented with severe mitral incompetence due to lupus valvulitis. The patient was clinically well with good valve function one year after surgery. Reconstructive mitral valve surgery may be preferable for the surgical management of mitral regurgitation in active lupus valvulitis since it eliminates the need for anticoagulation and avoids the disadvantages of different types of prostheses in these young patients who are under prolonged steroid therapy and have usually associated renal failure.

Adult↗

Effect of warm heart surgery on perioperative management of patients undergoing urgent cardiac surgery.

The anesthetic management and outcome data were examined in a retrospective case-controlled study that compared a conventional hypothermic cardioplegic technique with the recently described method of warm heart surgery, in patients undergoing urgent cardiac surgery. Hypothermic continuous oxygenated blood crystalloid cardioplegia with systemic hypothermia was used for 37 patients who underwent cardiac surgery by the same surgeon over a 16-month period from July 1986 (group 1), whereas normothermic continuous oxygenated blood crystalloid cardioplegia with systemic normothermia was used on 56 patients over the following 16-month period until March 1990 (group 2). The groups were similar in terms of age, sex, ASA status, NYHA classification, and preoperative left ventricular function. Defibrillation following cardiopulmonary bypass was required in only 3.6% of the warm heart surgery patients (group 2) compared with 83.8% in group 1 (P less than 0.0001), and use of warm heart surgery (group 2) eliminated the need for rewarming. There was a trend towards a reduced incidence of myocardial infarction (19% in group 1 vs 9% in group 2), low cardiac output syndrome (40% vs 29%), and use of the intraaortic balloon pump (16% vs 9%) in warm heart surgery patients, but these differences did not reach statistical significance. There were no differences between the two groups in terms of anesthetic drug usage, total heparin or protamine doses, blood loss, transfusion requirements, or duration of ICU stay.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, General↗

Retrograde continuous warm blood cardioplegia: a new concept in myocardial protection.

This report presents the results in our first clinical series of patients receiving continuous warm blood cardioplegia through the coronary sinus. Warm oxygenated blood cardioplegia has certain theoretical advantages, such as continuously supplying oxygen and substrates to the arrested heart while avoiding the side effects of hypothermia. Retrograde infusion of cardioplegia also offers certain advantages (eg, in valve operations and in patients with severe coronary artery disease) that are complementary to warm blood cardioplegia. Retrograde warm blood cardioplegia was used in 113 consecutive patients (85 men and 28 women with a mean age of 61 years) undergoing various procedures. Three percent of the patients died, 7% needed transient intraaortic balloon pump support, 6% had evidence of perioperative myocardial infarction, and 96% had spontaneous return of rhythm. There were no coronary sinus injuries. This new technique of retrograde continuous warm blood cardioplegia is a simple, safe, and reliable method of myocardial protection that may change the way we currently protect the heart intraoperatively.

Adult↗

Warm heart surgery: experience with long cross-clamp times.

Although hypothermic cardioplegic arrest prolongs the period of ischemic arrest by reducing oxygen demands, it leaves the heart dependent solely on anaerobic metabolism for its energy demands and exposes it to the detrimental effects of hypothermia. Consequently, myocardial protection is compromised, and safe aortic occlusion time is limited to 120 minutes. As electromechanical arrest accounts for 90% of myocardial oxygen consumption, we hypothesized that an ideal state of the heart might be chemically arrested and perfused with warm blood, ie, aerobic arrest. We applied this approach to myocardial protection in 308 consecutive procedures. To assess the adequacy of this method, we reviewed the results in a group of 22 patients in whom the aortic cross-clamp time was, of necessity, greater than or equal to 3 hours (mean time, 204 minutes; range, 180 to 393 minutes). Nineteen of the patients represented a high operative risk with grade 3 or 4 left ventricular function and New York Heart Association class III or IV. All hearts resumed spontaneous normal sinus rhythm without defibrillation, and 21 patients were easily weaned from bypass within minutes of removal of the aortic cross-clamp without inotropic or intraaortic balloon pump support. Mortality was 4.5%, low-output syndrome occurred in 4.5%, and there were no perioperative myocardial infarctions. Our results suggest that warm aerobic arrest is safe and effective in prolonged high-risk procedures, virtually eliminating the period of ischemia, limiting the period and injury of reperfusion, and abolishing the detrimental effects of hypothermia.

Aged↗

Warm heart surgery.

Hypothermia is widely acknowledged to be the fundamental component of myocardial protection during cardiac operations. Although it prolongs the period of ischemic arrest by reducing oxygen demands, hypothermia is associated with a number of major disadvantages, including its detrimental effects on enzymatic function, energy generation, and cellular integrity. We hypothesized that the ideal protected state of the heart would be electromechanically arrested and perfused with blood, that is, aerobic arrest. Under these conditions the fundamental need for hypothermia becomes questionable. We have developed a novel approach to myocardial protection during cardiac operations based on these concepts, in which the chemically arrested heart is perfused continuously with blood and maintained at 37 degrees C. In 121 consecutive coronary bypass procedures we have compared this approach with a historical cohort of 133 consecutive patients treated with hypothermic cardioplegia. Perioperative myocardial infarction was significantly less prevalent (1.7% versus 6.8%; p less than 0.05) in the warm cardioplegic group, as was the use of the intraaortic balloon pump (0.9% versus 9.0%; p less than 0.005) and the prevalence of low output syndrome (13.5% versus 3.3%; p less than 0.005). Cardiac output immediately after bypass was significantly higher than before bypass (3.1 +/- 0.9 versus 4.9 +/- 1.0 L/min; p less than 0.001) only in the warm cardioplegia group. Furthermore, the heartbeat in 99.2% of patients treated with continuous warm cardioplegia converted to normal sinus rhythm spontaneously after removal of the aortic crossclamp compared with only 10.5% of the hypothermic group. The time from removal of the aortic crossclamp to discontinuation of cardiopulmonary bypass (i.e., reperfusion time) was significantly shorter in the warm cardioplegia group (11 +/- 4.3 versus 27 +/- 5.6 minutes; p less than 0.001). Our results suggest that continuous normothermic blood cardioplegia is safe and effective. Conceptually, this represents a new approach to the problem of maintaining excellent myocardial preservation during cardiac operations.

Aged↗

Continuous warm blood cardioplegia: a new technique for myocardial protection.

Hypothermia is used to prolong the safe period of ischemic arrest by reducing the heart's oxygen demands. Due to this effect, hypothermia has been the fundamental component of most methods of myocardial protection during cardiac surgery. However, hypothermia has a number of unwanted side effects, such as detrimental effects on enzyme function, energy generation, and cell membranes. Since electromechanical arrest accounts for 90% of myocardial oxygen consumption, arresting the heart with chemical cardioplegia will reduce O2 consumption dramatically. Therefore, if the resting (arrested) heart is continuously perfused with oxygenated blood cardioplegia, one can easily provide the remaining 10% of O2 that it requires. Under these conditions, the need for hypothermia becomes questionable. In this paper, we describe the perfusionist's experience using the antegrade and retrograde technique of continuous warm blood cardioplegia.

Blood↗