PubMed Health⌕ Search

Biomedical subjects

A Pape

Publications and source records attributed to A Pape.

At least 19 recordsLinked to original sources

Calculation of transmission coefficients for some permeant molecules in human red cell and resting axolemma squid axon membranes.

Quantum mechanical calculations of transmission coefficients for some permeant molecules across the human red cell and resting axolemma squid axon membranes are carried out. The calculations depend on (i) the molecular weight of the molecule and (ii) the depth and width of the potential well of the membrane. In most cases good agreement between calculated and experimental values is found.

Animals↗

[Tolerance to perioperative anemia. Mechanisms, influencing factors and limits].

The expected cost explosion in transfusion medicine (increasing imbalance between donors and potential recipients, treatment of transfusion-associated complications) increases the socio-economic significance of specific institutional transfusion programs. In this context the estimated use of the patient's physiologic tolerance to anemia enables 1) the tolerance of larger blood losses (loss of "diluted blood"), 2) the onset of transfusion to the time after surgical control of bleeding to be delayed and 3) the perioperative collection of autologous red blood cells. The present review article summarizes the mechanisms, influencing factors and limits of this natural tolerance to anemia and deduces the indication for perioperative red blood cell transfusion. Under strictly controlled conditions (anesthesia, normovolemia, complete muscular relaxation, hyperoxemia, mild hypothermia) extremely low hemoglobin concentrations [Hb <3 g/dl (<1.86 mmol/l)] are tolerated without transfusion by individuals with no cardiopulmonary disease. In the clinical routine these situations are limited to borderline situations e.g. unexpected massive blood losses in Jehovah's Witnesses or unexpected shortcomings in blood supply. The current recommendations coincide to the effect that perioperative red blood cell transfusion 1) is unnecessary up to a Hb concentration of 10 g/dl (6.21 mmol/l) even in older patients with cardiopulmonary comorbidity and 2) is only recommended in cases of Hb <6 g/dl (<3.72 mmol/l) in otherwise healthy subjects including pregnant women and children. Critically ill patients with multiple trauma and sepsis do not seem to benefit from transfusions up to Hb concentrations >9 g/dl (>5.59 mmol/l). In cases of massive hemorrhaging and diffuse bleeding disorders the maintenance of a Hb concentration of 10 g/dl (6.21 mmol/l) seems to contribute to stabilization of coagulation.

Anemia↗

Hyperoxic ventilation increases the tolerance of acute normovolemic anemia in anesthetized pigs.

OBJECTIVE: To investigate the impact of prophylactic hyperoxic ventilation with Fio2 0.6 on the physiologic limit of acute normovolemic anemia. DESIGN: Prospective, controlled, randomized experimental study. SETTING: Experimental animal laboratory of a university hospital. SUBJECTS: Fourteen anesthetized domestic pigs. INTERVENTIONS: Animals were randomly ventilated with either Fio2 0.21 (group 0.21, n = 7) or Fio2 0.6 (group 0.6, n = 7), and acute anemia was induced by isovolemic blood-for-hydroxy-ethylstarch (HES) exchange using a 6% HES solution (130/0.4). MEASUREMENTS AND MAIN RESULTS: The blood-for-HES-exchange was continued until a sudden decrease of total body oxygen consumption indicated the onset of oxygen supply dependency (primary end point); the corresponding hemoglobin (Hb) concentration was defined as "critical" (Hb(crit)). Secondary end points were changes in myocardial function, central hemodynamics, oxygen transport, and tissue oxygenation. Compared with room air ventilation (Fio2 0.21), hyperoxic ventilation with Fio2 0.6 enabled a larger blood-for-HES-exchange (139%, 124/156) of circulating blood volume vs. 87% (68/94, p < .05), until Hb(crit) was reached (1.5 g/dL [1.4/2.1] vs. 2.4 g/dL [2.0/2.8], p < .05). At Hb 2.4 g/dL (i.e., Hb(crit) in group 0.21), animals of group 0.6 still presented with superior oxygen transport, tissue oxygenation, and hemodynamic stability. However, hemodynamic and oxygen transport variables were found deteriorated more severely at Hb 1.5 g/dL (i.e., Hb(crit) of group 0.6) compared with group 0.21 at Hb 2.4 g/dL. CONCLUSION: During cell-free volume replacement, hyperoxic ventilation with Fio2 0.6 generates a readily usable plasmatic oxygen reserve and thereby increases the tolerance toward acute normovolemic anemia.

Anemia↗

Hyperoxic ventilation enables hemodilution beyond the critical myocardial hemoglobin concentration.

BACKGROUND: When initiated in anemic hypoxia, hyperoxic ventilation (ventilation with pure O2, FiO2 1.0, HV) reverses hypoxia-induced ECG-changes and enables survival for several hours. The quantification of the HV-induced gain in anemia tolerance and particularly the Hb-equivalent of HV in this situation are unknown. METHODS: Nine anaesthetized pigs were hemodiluted under normoxia (FiO2 0.21) by exchange of whole blood for hydroxyethyl starch (HES) until predefined, ischemia associated ECG-changes occurred (timepoint Hb(crit)). From that time on all animals were ventilated with 100% O2 (FiO2 1.0). In the case of disappearance of the ECG changes with onset of HV, the animals were further hemodiluted until ECG changes reoccurred. RESULTS: HV initiated in anemic hypoxia (Hb 2.3 +/- 0.2 g/dl) improved ECG-readings of all animals, and allowed for a further exchange of 14 +/- 11 ml/kg blood until ECG-changes reoccurred at Hb 1.2 +/- 0.4 g/dl. CONCLUSION: HV initiated in anemic hypoxia creates a margin of safety for myocardial tissue oxygenation and thus further increases anemia tolerance. The Hb equivalent of HV in this situation amounts to approximately 1g/dl.

Animals↗

[Artificial oxygen carriers as an alternative to red blood cell transfusion].

The expected cost-explosion in transfusion medicine (increasing imbalance between donors and recipients, treatment of transfusion-associated complications) increases the socio-economic significance of the development of safe and effective synthetic oxygen carriers as an alternative to the transfusion of allogeneic red blood cells. Currently two types of artificial oxygen carriers have been tested for safety and efficacy in cases of severe anemia otherwise requiring transfusion. Solutions based on human or bovine hemoglobin (HBOC) possess vasoconstrictor properties in addition to their oxygen transport capacity. The impact of vasoconstriction on tissue perfusion and organ function is however not yet fully understood. Nevertheless, in 2001 the bovine HBOC Hemopure was approved in South Africa for treatment of acutely anemic surgical patients. The purely synthetic perfluorocarbon (PFC) emulsions increase the physically dissolved portion of arterial oxygen content. Due to their particulate nature (emulsion droplets) PFCs may only be infused in low doses to avoid overload and malfunction of phagocytic cells of the reticulo-endothelial system. As part of a multimodal blood conservation program (including normovolemic hemodilution and hyperoxia) the low-dose administration of Oxygent effectively increases intraoperative anemia tolerance. Although reduction of perioperative allogeneic blood transfusion has already been demonstrated for HBOC and PFC, the global clinical establishment of artificial oxygen carriers is not to be expected in the near future.

Animals↗

[Indications for blood transfusion during orthopedic surgery].

Ageing of the population increases the number of large orthopedic surgical interventions in elder people. High perioperative blood loss together with a reduced tolerance to anemia increase the transfusion probability in this patient subgroup. The expected cost explosion in the transfusion system (cost intensive quality management, imbalance between the number of donors and recipients) as well as the remaining transfusion related risk of hemolysis, infection and immunosuppression reflect the high socio-economic significance of the development of institutional transfusion programs. The present article summarizes: (1) the (patho-) physiology of anemia compensation, (2) the decision making for transfusion in healthy patients and patients with cardiovascular disease, and (3) the currently applied pre- and intraoperative techniques to reduce allogeneic transfusion in orthopedic patients.

Aged↗

Effects of standardized acute normovolemic hemodilution on intraoperative allogeneic blood transfusion in patients undergoing major maxillofacial surgery.

The aim of the present study was to demonstrate the practicality and efficacy of acute normovolemic hemodilution (ANH) to reduce allogeneic red blood cell (RBC) transfusion in patients undergoing elective surgery with anticipated high intraoperative blood loss (BL). 124 patients (age 48 +/- 18 years, ASA classes I-III) underwent major maxillofacial surgery in a university hospital (68% tumor surgery, 32% dysgnathia correction). After induction of general anesthesia, ANH was performed by standardized withdrawal of 900 ml (2 units) of whole blood and simultaneous infusion of 500 ml of hydroxyethyl starch solution (6% HES 130,000/0.4) and 1500 ml of crystalloidal solution. Intraoperative BL was fluid-compensated until physiologic parameters indicated the need for RBC transfusion. First, autologous ANH-blood was retransfused followed by, if necessary, allogeneic RBC. Total BL was referred to the patient's calculated blood volume (BV): fractional blood volume loss, BL(fract) = BL/BV. ANH took 16 +/- 2 min and was void of any adverse event. The costs for ANH was 24 per patient. 55 patients had a mean BL(fract) of 44 +/- 28% and required an intraoperative transfusion; 49/55 patients with an average BL(fract) of 37 +/- 14% were transfused with only autologous ANH-blood; 6/55 patients with a mean BL(fract) of 100 +/- 47% underwent additional transfusion with allogeneic RBC. Standardized, 2 unit, ANH is a practicable, safe and economic blood conservation technique that allowed for the complete avoidance of allogeneic RBC transfusion in 89% of patients undergoing maxillofacial surgery that required an intraoperative RBC transfusion.

Adult↗

Comparison of imaging plates with track detectors for fast-neutron dosimetry.

Imaging plate (IP) radiation detectors are widely used in industrial radiography, medical imagery and autoradiography. When an IP is exposed to ionising radiation, some of the energy is absorbed to form a latent image. The energy stored, which is proportional to the dose received, can be liberated by a selective optical stimulation and collected to reconstitute the distribution of the ionising radiation on the IP. In this work, IPs for use in fast-neutron measurements are characterised. The response of our IP dosemeters in conjunction with their reading system was found to be linear in dose between 75 microSv and 10 mSv. This performance is compared with those of dosemeters based on the plastic track detectors PN3 and CR-39.

Body Burden↗

Fluid resuscitation from severe hemorrhagic shock using diaspirin cross-linked hemoglobin fails to improve pancreatic and renal perfusion.

BACKGROUND: Fluid resuscitation from hemorrhagic shock is intended to abolish microcirculatory disorders and to restore adequate tissue oxygenation. Diaspirin cross-linked hemoglobin (DCLHb) is a hemoglobin-based oxygen carrier (HBOC) with vasoconstrictive properties. Therefore, fluid resuscitation from severe hemorrhagic shock using DCLHb was expected to improve perfusion pressure and tissue perfusion of kidneys and pancreas. METHODS: In 20 anesthetized domestic pigs with an experimentally induced coronary stenosis, shock (mean arterial pressure 45 mmHg) was induced by controlled withdrawal of blood and maintained for 60 min. Fluid resuscitation (replacement of the plasma volume withdrawn during hemorrhage) was performed with either 10% DCLHb (DCLHb group, n = 10) or 8% human serum albumin (HSA) oncotically matched to DCLHb (HSA group, n = 10). Completion of resuscitation was followed by a 60-min observation period. Regional blood flow to the kidneys and the pancreas was measured by use of the radioactive microspheres method at baseline, after shock and 60 min after fluid resuscitation. RESULTS: All animals (10/10) resuscitated with DCLHb survived the 60-min observation period, while 5/10 control animals died within 20 min due to persisting subendocardial ischemia. In contrast to HSA survivors, pancreas and kidneys of DCLHb-treated animals revealed lower total and regional organ perfusion and regional oxygen delivery. Renal and pancreatic blood flow heterogeneity was higher in the DCLHb group. CONCLUSION: DCLHb-induced vasoconstriction afforded superior myocardial perfusion, but impaired regional perfusion of the kidneys and the pancreas.

Algorithms↗

Changes in p(i)CO(2) reflect splanchnic mucosal ischaemia more reliably than changes in pH(i) during haemorrhagic shock.

BACKGROUND: Gastric tonometry is intended to reveal alterations in splanchnic perfusion and oxygenation. Based on the tonometric measurement of gastric mucosal partial pressure of carbon dioxide (pCO(2)) and the simultaneous determination of arterial blood gas parameters (bicarbonate concentration [HCO(3-)], pH and pCO(2)), several parameters can be calculated. AIMS: To identify the most suitable tonometric parameter [gastric mucosal pH (pH(i)), intramucosal pCO(2) (p(i)CO(2)), the difference between tonometric and arterial pCO(2) concentrations (pCO(2) gap), [H+] gap] that reliably reflects gastric hypoperfusion and hypoxia during severe haemorrhagic shock. DESIGN: Randomised, controlled experimental study. METHODS: An artificial stenosis of the left anterior descending coronary artery (LAD) was induced. Subsequently, the animals were haemorrhaged to a mean arterial pressure of 45 mmHg, which was maintained for 60 min. MEASUREMENTS AND MAIN RESULTS: Tonometric measurements were performed in 17 land-race pigs before and after induction of LAD stenosis and after haemorrhagic shock. P values obtained using the Wilcoxon signed-rank testing were used to compare the level of significance for the tonometric parameters and the corresponding arterial blood gas values [arterial pCO2 (p(a)CO(2)), [HCO(3-)], arterial pH (pH(a))]. While induction of critical coronary stenosis did not provoke any changes, all parameters changed significantly during haemorrhagic shock. The lowest P value was found for pH(i) (P=0.00013) followed by [H+ gap] (P=0.0005). P values higher by a factor of ten were found for pCO(2) gap (P=0.00119) and were highest for p(i)CO(2) (P=0.00562). P values of the corresponding arterial blood gas parameters were lower by a factor of ten than the P value of p(i)CO(2). CONCLUSION: pH(i), pCO(2) gap and [H+] gap are considerably influenced by changes of systemic arterial blood gas values. This is demonstrated by lower P values of the corresponding arterial blood gas values in comparison with p(i)CO(2). Therefore pH(i), pCO(2) gap and [H+] gap seem to indicate more likely systemic changes, whereas p(i)CO(2) appears to reflect disturbances of regional gastric tissue perfusion and oxygenation more reliably than any other derived tonometric parameter.

Animals↗

Diaspirin crosslinked hemoglobin enables extreme hemodilution beyond the critical hematocrit.

BACKGROUND: Normovolemic hemodilution is an effective strategy to limit perioperative homologous blood transfusions. The reduction of hematocrit related to hemodilution results in reduced arterial oxygen content, which initially is compensated for by an increase in cardiac output and oxygen extraction ratio. To increase the efficacy of hemodilution, a low hematocrit should be aimed for; however, this implies the risk of myocardial ischemia and tissue hypoxia. OBJECTIVE: To assess whether hemodilution can be extended to lower hematocrit values by the use of a hemoglobin-based artificial oxygen carrier solution. DESIGN: Prospective, randomized, controlled. SETTING: Animal laboratory of a university hospital. SUBJECTS: Twelve anesthetized, mechanically ventilated pigs. INTERVENTIONS: Isovolemic hemodilution was performed with either 10% diaspirin crosslinked hemoglobin (DCLHb Baxter Healthcare, Boulder, CO; n = 6) or 8% human albumin solution (HSA, oncotically matched to DCLHb, Baxter Healthcare; n = 6) to a hematocrit of 15%, 8%, 4%, 2%, and 1%. MEASUREMENTS AND MAIN RESULTS: In both groups, measurements were performed at baseline at the previously mentioned preset hematocrit values and at the onset of myocardial ischemia characterized by critical hematocrit (significant ST-segment depression >0.1 mV and/or arrhythmia). To determine peripheral tissue oxygenation and myocardial perfusion and function, the following variables were evaluated: total body oxygen transport variables, tissue oxygen partial pressure (tPo2, MDO-Electrode, Eschweiler Kiel, Germany) on the surface of the skeletal muscle, coronary perfusion pressure, left ventricular (LV) end-diastolic pressure, global and regional myocardial contractility (maximal change in pressure over time, LV segmental shortening, microsonometry method), LV myocardial blood flow (fluorescent microsphere technique), LV oxygen delivery, and the ratio between LV subendocardial and subepicardial myocardial perfusion. In the HSA group, critical hematocrit was found at 6.1 (1.8)% (hemoglobin, 2 g x dL(-1)), whereas all DCLHb-treated animals survived hemodilution until hematocrit 1.2 (0.2)% (hemoglobin, 4.7 g x dL(-1)) was achieved without signs of hemodynamic instability. Although arterial oxygen content was higher in the DCLHb group at 1.2% hematocrit than in the HSA group at critical hematocrit (i.e., hematocrit, 6.1%; hemoglobin, 2 g.dL-1) neither oxygen delivery and oxygen uptake nor median tPo2 and hypoxic tPo2 values on the skeletal muscle were different between groups. In contrast, subendocardial ischemia was absent in DCLHb-diluted animals until 1.2% hematocrit was achieved. This was attributable to a higher coronary perfusion pressure (65 (22) mm Hg vs. 19 (8) mm Hg; p <.05), higher subendocardial perfusion (4.1 (2.6) mL.min-1.g-1 vs. 1.2 (0.4) mL x min(-1) x g(-1)), and subendocardial oxygen delivery (5.7 (2) mL x min(-1) x g(-1), p <.05) in DCLHb-diluted animals, resulting in superior myocardial contractility reflected by maximal change in pressure over time (3829 (1914) vs. 1678 (730); p <.05) and higher regional myocardial contractility (11 (8)% vs. 6 (2)%; p <.05). An increased LV end-diastolic pressure reflected LV myocardial pump failure in HSA-diluted animals but was unchanged in DCLHb-diluted animals. In the DCLHb group, systemic vascular resistance index remained at baseline values throughout the protocol, whereas coronary vascular resistance decreased. In contrast, both variables decreased in HSA-diluted animals. CONCLUSION: DCLHb as a diluent allowed for hemodilution beyond the hematocrit value, determined "critical" after hemodilution with HSA (6.1% (1.8)%). Even at 1.2% hematocrit (hemoglobin, 4.7 g x dL(-1)) myocardial perfusion and function were maintained, although at the expense of peripheral tissue oxygenation. This discrepancy in regional oxygenation might be caused by a redistribution of blood flow favoring the heart, which is related to a disproportionate decrease of coronary vascular resistance index during hemodilution with DCLHb.

Animals↗

Extent of microbial contamination in United States pork retail products.

To determine the extent of microbiological contamination of U.S. pork, 384 samples of retail pork were collected from 24 stores in six cities, including (i) whole-muscle, store-packaged pork; (ii) fresh, store-packaged ground pork and/or pork sausage; (iii) prepackaged ground pork and/or pork sausage; and (iv) whole-muscle, enhanced (injected or marinated; 60% store-packaged, 40% prepackaged) pork. Additional samples (n = 120) of freshly ground pork and/or pork sausage were collected from two hot-boning sow/boar sausage plants, two slaughter and fabrication plants, and two further-processing plants. Samples were analyzed for aerobic plate counts (APC), total coliform counts (TCC), Escherichia coli counts (ECC), and incidences of Salmonella spp., Listeria monocytogenes, Campylobacter jejuni, Campylobacter coli, and Yersinia enterocolitica. Mean log APC and TCC were highest (P < 0.05) for store-ground pork, while whole-muscle, enhanced products and prepackaged ground products had the lowest (P < 0.05) APC. Mean log APC and TCC were higher (P < 0.05) in samples from the slaughter and fabrication plants than in samples from hot-boning and further processing plants. Mean log ECC were lower (P < 0.05) in samples from further-processing plants compared to slaughter and fabrication plants and hot-boning, sow and boar sausage plants. L. monocytogenes was detected in 26.7% of plant samples and 19.8% of retail samples and was present more frequently in ground products. Y. enterocolitica was detected most often in whole-muscle, store-packaged cuts (19.8%) and in store-ground product (11.5%). Salmonella spp. were found in 9.6% of retail samples and 5.8% of plant samples, while C. jejuni and C. coli were found in 1.3% of retail samples and 6.7% of plant samples. Pork products exposed to the most handling and processing appeared to be of the poorest microbiological quality. These results should be useful in risk assessments that are directed at the identification of actions that could enhance food safety.

Animals↗

Diaspirin-crosslinked hemoglobin reduces mortality of severe hemorrhagic shock in pigs with critical coronary stenosis.

OBJECTIVE: To evaluate the effects of resuscitation with a 10% diaspirin-crosslinked hemoglobin (DCLHb) solution on global hemodynamic variables, systemic and myocardial oxygen transport and tissue oxygenation, and contractile function of the left ventricle in an experimental model of severe hemorrhagic shock and critical stenosis of the left anterior descending coronary artery (LAD). DESIGN: Prospective, placebo-controlled, randomized study. SETTING: Experimental animal laboratory. SUBJECTS: A total of 20 anesthetized pigs. INTERVENTIONS: After implementation of a permanent critical LAD stenosis (ie, maintenance of basal blood flow but absence of reactive hyperemia after a 10-sec complete vessel occlusion), hemorrhagic shock (target mean aortic pressure, 45 mm Hg) was induced within 15 mins by programmed withdrawal of blood and maintained for 60 mins. Subsequently, the volume of plasma lost during hemorrhage was replaced by either a balanced electrolyte solution containing 10 g/dL DCLHb (DCLHb group; n = 10) or an 8 g/dL human albumin solution (HSA) oncotically matched to DCLHb (HSA group; n = 10). Data were collected immediately after the infusion of the different solutions and again after 60 mins had elapsed. MEASUREMENTS AND MAIN RESULTS: Although five of ten HSA-treated animals died of acute left ventricular failure within the first 20 mins after complete fluid resuscitation, all of the DCLHb-treated animals survived the 60-min observation period after resuscitation (p < .05). This significant difference in mortality is explained by higher coronary perfusion pressure in DCLHb-treated animals (75 +/- 17 vs. 27 +/- 17 torr DCLHb vs. HSA group; p < .05) and persistence of subendocardial ischemia and hypoxia (radioactive microspheres method) in HSA-treated animals on resuscitation particularly affecting the LAD-supported myocardium (subendocardial oxygen delivery: 20 +/- 11 vs. 3 +/- 1 mL oxygen x g(-1) x min(-1), DCLHb vs. HSA group; p < .05). Except for enhanced myocardial contractility immediately on infusion of DCLHb (maximal left ventricular pressure increase: 2373 +/- 782 vs. 1730 +/- 543 torr x sec(-1) DCLHb vs. HSA group; p < .05), no differences were detected between groups concerning the variables of systemic oxygen transport, tissue oxygenation, and regional contractile function of the myocardium (determined with microsonometry). CONCLUSIONS: Fluid resuscitation with 10% DCLHb solution completely reverses hemorrhagic shock-induced subendocardial ischemia and hypoxia in the presence of compromised coronary circulation and thereby prevents early death after resuscitation.

Animals↗

Effects of primary resuscitation from shock on distribution of myocardial blood flow.

Hemorrhagic shock alters heterogeneity of regional myocardial perfusion (RMP) in the presence of critical coronary stenosis in pigs. Conventional resuscitation has failed to reverse these effects. We hypothesized that improvement of the resuscitation regime would lead to restoration of RMP heterogeneity. Diaspirin-cross-linked hemoglobin (10 g/dl; DCLHb) and human serum albumin (8.0 g/dl; HSA) were used. After baseline, a branch of the left coronary artery was stenosed; thereafter, hemorrhagic shock was induced. Resuscitation was performed with either DCLHb or HSA. At baseline, the fractcal dimension (D) of subendocardial myocardium was 1.31 +/- 0.083 (HSA) and 1.35 +/- 0.106 (DCLHb) (mean +/- SD). Coronary stenosis increased subendocardial D slightly but consistently only in the DCLHb group (1.39 +/- 0.104; P < 0.05). Shock reduced subendocardial D: 1.21 +/- 0.093 (HSA; P = 0.10), 1.25 +/- 0.092 (DCLHb; P < 0.05). Administration of DCLHb increased subendocardial D in 7 of 10 animals (1.31 +/- 0.097; P = 0.066). HSA was ineffective in this respect. DCLHb infusion restored arterial pressure and increased cardiac index (CI) to 80% of baseline values. Administration of HSA left animals hypotensive (69 mmHg) and increased CI to 122% of the average baseline value. Shock-induced disturbances of the distribution of RMP were improved by administration of DCLHb but not by HSA.

Animals↗

Heat stress does not modify lactate exchange and removal abilities during recovery from short exercise.

Arterial and femoral venous lactate concentrations were measured before, during, and after short intermittent exercise (55-118% of maximal O2 consumption) in thermoneutral (N, 25 degrees C, 10.5 Torr) and hot (H, 45 degrees C, 17.5 Torr) conditions. The thermal load induced significantly higher heart rate and rectal temperature in H relative to N. All the arterial lactate (La) recovery curves were fitted to an equation containing two exponential time functions of the form La(t) = La(0) + A1a(1 - e-gamma 1at) + A2a(1 - e-gamma 2at) where the velocity constants gamma 1a and gamma 2a are the body's overall ability to exchange and remove lactate after exercise, respectively, and t is time. There was no significant difference in these constants, regardless of thermal conditions. The arterial lactate concentration at the end of exercise, the peak lactate concentration during recovery, the amplitudes A1a and A2a of the biexponential function, and the arteriofemoral venous lactate concentration difference during recovery were not significantly different in H relative to N. However, measured and computed arterial lactate concentrations during recovery, especially at the end of the tests, were higher in H (P < 0.04). The more elevated lactate concentrations in H at rest at the end of recovery denote a higher basal lactate production, and they were not due to muscle hypoxia.

Adult↗