Evaluation of a new automated instrument for pretransfusion testing.

BACKGROUND: A number of automated devices for pretransfusion testing have recently become available. This study evaluated a fully automated device based on column agglutination technology (AutoVue System, Ortho, Raritan, NJ). STUDY DESIGN AND METHODS: Some 6747 tests including forward and reverse ABO group, Rh type and phenotype, antibody screen, autocontrol, and crossmatch were performed on random samples from 1069 blood donors, 2063 patients, and 98 newborns and cord blood. Also tested were samples from 168 immunized patients and 53 donors expressing weak or variant A and D antigens. Test results and technician times required for their performance were compared with those obtained by standard methods (manual column agglutination technology, slide, semiautomatic handler). RESULTS: No erroneous conclusions were found in regard to the 5028 ABO group and Rh type or phenotype determinations carried out with the device. The device rejected 1.53 percent of tests for sample inadequacy. Of the remaining 18 tests with discrepant results found with the device and not confirmed with the standard methods, 6 gave such results because of mixed-field reactions, 10 gave negative results with A2 RBCs in reverse ABO grouping, and 2 gave very weak positive reactions in antibody screening and crossmatching. In the samples from immunized patients, the device missed one weak anti-K, whereas standard methods missed five weak antibodies. In addition, 48, 34, and 31 of the 53 weak or variant antigens were detected by the device, the slide method, and the semiautomated handler, respectively. Technician time with the standard methods was 1.6 to 7 times higher than that with the device. CONCLUSION: The technical performance of the device compared favorably with that of standard methods, with a number of advantages, including in particular the saving of technician time. Sample inadequacy was the most common cause of discrepancy, which suggests that standardization of sample collection can further improve the performance of the device.

ABO Blood-Group System↗

Implementation of a quality system (ISO 9000 series) for placental blood banking.

Although placental blood has recently become a new source of hematopoietic progenitors for marrow replacement, limited attention has been given to systems suitable to ensure the short-term and long-term quality of placental blood units used for transplantation. In this article, we describe a quality system for placental blood banking developed in accord with ISO 9002 norms at Milano Cord Blood Bank. The quality system is the organizational structure, procedures, processes, and resources needed to implement quality management. ISO 9002 is a model for quality assurance in production, installation, and servicing, which includes a number of clauses providing guidance for the implementation of the quality system. The quality system was started by the bank medical director with step 1: the general quality plan, which included (a) the written description of mission, objectives, technical and organizational policies, and staff organization chart of the placental blood bank, (b) the definition and acquisition of adequate financial, human, and structural resources, (c) the appointment of a quality system head independent from the production laboratory and reporting directly to the medical director. Tasks of the quality system head were (a) to identify the placental blood banking process together with the placental blood bank personnel, (b) to implement a documentation plan finalized at the production and maintenance of (i) the quality manual, which provides a summary on how the bank operates with a quality system in compliance with the ISO 9002 clauses, (ii) the general procedures (or quality system procedures), which provide more detail on selected clauses, including at least those prescribed by the ISO 9002 standard, (iii) the operative procedures (or process procedures), which describe in detail the process of placental blood banking and how technical activities must be performed, (iv) the work instructions, which provide stepwise descriptions of individual activities, (v) records/forms for data collection and storage, (c) to identify quality indicators, (d) to start a regular internal audit, (e) to report audit results to the medical director for review. This was followed by step 2: the job descriptions, staff training, and qualification; step 3: the documentation plan; step 4: the internal audit plan; step 5: the launch of the quality system, and step 6: the assessment by an external team from an accredited third-party organization and final certification for compliance to ISO 9002. The quality system, which must be maintained and undergo external audit at regular intervals so that certification is confirmed, ensures the high probability that placental blood units provided to clinicians conform regularly to predefined levels of quality.

Blood Banks↗

Use of SERVQUAL to assess clinicians' satisfaction with the blood transfusion service.

BACKGROUND AND OBJECTIVES: Limited information is available on the level of satisfaction of clinicians with services delivered by blood banks. The purpose of this study was to evaluate the satisfaction of clinicians with our blood transfusion service. MATERIALS AND METHODS: We prepared a questionnaire based on SERVQUAL, a method used to measure customers' appreciation of quality of service, by assessing the gap between perceived and expected quality. The questionnaire consisted of 14 items grouped according to five dimensions of quality of service: assurance, empathy, responsiveness, reliability, tangibles. Clinicians were asked to give two scores on a scale from 1 to 7 for each item, score (e) representing what they expected from an 'excellent' service, score (r) how they graded the service received. We considered wide differences in scores of service expectation and receipt for a question to be indicative of either service above expected levels (r > e) or service below expectation (r < e); similar scores for both expected and received service (within 1 point on the grading scale) were taken to indicate that the service received was that which was expected. RESULTS: A total of 184 questionnaires (49%) were returned. For the 14 items considered, the proportion of clinicians expressing levels of satisfaction similar to or above expectation ranged from 67 to 96%. Three critical areas, which clinicians considered important (expectation scores 6-7) were associated with satisfaction below expectation in more than 20% of responders. They were: clarity of procedures, clarity of blood request forms, and convenience of blood request and issuing times, which were rated as important by 77, 80 and 72% of clinicians, respectively. CONCLUSION: SERVQUAL was useful to gather information on the level of clinicians' satisfaction with our transfusion service.

Ancillary Services, Hospital↗

Quality control of red cell filtration at the patient's bedside.

BACKGROUND: Concern has been raised about the quality of white cell (WBC) reduction in blood components when it is performed by filtration at the patient's bedside. Thus, the quality of red cell (RBC) filtration performed at the bedside through two new flatbed WBC-reduction filters was evaluated. STUDY DESIGN AND METHODS: In the laboratory, 25 and 10 RBC units suspended in additive solution were stored for 1 to 2 and 14 to 21 days, respectively, and filtered through each filter. At the end of filtration, an automated complete blood count and a manual WBC count (Nageotte chamber) were determined in two samples collected from 1) a segment clamped at 5 and 25 cm below the filter along the line connecting prefiltration and postfiltration bags and 2) the postfiltration bag. In addition, 10 of the 11 nurses of the hematology outpatient clinic administered to hematologic patients 25 RBC units stored for 1 to 2 days through each type of filter. At the end of transfusion, a segment was collected from the transfusion set and a WBC count was performed as described above. No filter priming or rinsing with saline was done. RESULTS: WBC counts obtained after laboratory filtration in the segments were similar to those obtained from the postfiltration bags and from the segments collected at the bedside in all cases, with the exception of 14- to 21-day-old RBCs filtered in the laboratory through one of the filters, which produced slightly higher WBC counts in the segments than were seen in the postfiltration bags. The difference was not significant. In no case was the count in the postfiltration bag higher than that in the segment. Nurse training was easy, and bedside filtration was associated with no untoward effects. CONCLUSION: The RBC filtration at the patient's bedside can be equal in quality to that performed in the laboratory, at least in such clinical settings as hematology and oncology departments in which blood transfusion is common practice, and if simple training is provided to the nursing staff. Under the conditions of this study, it seems that quality control of RBC bedside filtration is feasible and simple.

Blood Transfusion↗

White cell-reduced red cells prepared by filtration: a critical evaluation of current filters and methods for counting residual white cells.

White cell (WBC) reduction, red cell (RBC) recovery, and filtration time were determined in 1-day-old standard and buffy coat-depleted RBCs filtered in the laboratory through six commercial filters for WBC reduction. Residual WBCs were counted with a Bürker chamber (BC), with a Nageotte chamber (NC), and by flow cytometry (FC). Results show that BC counts were 0 in several cases in which WBCs were detected with NC and FC, which indicated that the traditional BC method is too insensitive in use with currently available filters. Calibration curves performed by FC and with NC with samples containing known concentrations of WBCs from 1000 to 1 per microL showed that both FC and NC detected, on average, 67 percent of WBCs present in the samples (efficiency). However, the efficiency of FC showed small variability (61-70%) at different WBC levels, whereas the variability with NC was large (39-91%). This greater variability prevented the correction of NC counts by using a single factor and indicated difficulty in NC standardization. Therefore, because our main aim was to compare different filters rather than to define absolute levels of WBC contamination, uncorrected FC and NC counts were chosen to be reported. True WBC counts per unit should not exceed values that can be obtained by dividing uncorrected counts by the lowest efficiencies (61% for FC and 39% for NC). Uncorrected NC and FC counts were below 2 x 10(6) per unit in all units processed through three of the filters and below 5 x 10(6) per unit in all units processed through the other three.(ABSTRACT TRUNCATED AT 250 WORDS)

Erythrocytes↗

Prospective evaluation of posttransfusion hepatitis.

The incidence of posttransfusion hepatitis (PTH) was determined prospectively at our institution. An active surveillance program of transfused surgical patients was set up; alanine aminotransferase (ALT) levels were determined before transfusion and at monthly intervals for 6 months after transfusion. Patients with confirmed ALT values greater than 2.5 times the upper reference values were referred to the out-patient clinics for diagnosis. Of 4051 surgical patients who underwent transfusion between January 1986 and December 1989, 2459 (60.7%) were enrolled in the surveillance program, and 1018 (25.1%) completed the follow-up; 238 patients received autologous blood only and were used as controls. No PTH was observed in the control patients, and the incidence of the disease in patients receiving homologous blood was 10.97 percent in 1986, 6.58 percent in 1987, 5.55 percent in 1988, and 4.29 percent in 1989; the decreasing trend is significant (p = 0.018).

Alanine Transaminase↗

Removal of white cells from red cells by transfusion through a new filter.

The effectiveness of a new filter (RC100) for the preparation of white cell-depleted red cells (RBCs) at the bedside was evaluated in vitro and in vivo using three RBC products: standard RBC concentrate (CPDA units), RBCs suspended in saline-adenine-glucose-mannitol additive solution after the removal of plasma (SAGM units), and RBCs suspended in SAGM after the removal of plasma and buffy coat (SAGM-BC units). Median RBC recovery was at least 92 percent when 2 units were administered through one filter; median values for residual white cells and platelets were less than or equal to 20 x 10(6) and less than or equal to 2.5 x 10(9) per 2 units, respectively. The in vivo study was carried out in 80 multiply transfused patients with thalassemia, 35 of whom had experienced frequent nonhemolytic transfusion reactions when given standard or buffy coat-free RBCs. During the 6-month study, each patient was given two transfusions of each type of RBC product One febrile nonhemolytic transfusion reaction occurred in each of two patients receiving SAGM-BC units, but in no other case. If the flow rate is not reduced, the median transfusion time is 35 minutes per CPDA unit and 15 minutes per SAGM and SAGM-BC unit. It is concluded that the transfusion of RBCs through the RC100 is a simple and effective procedure to administer white cell-depleted RBCs prepared at the bedside.

Blood Transfusion↗

Prevalence of hepatitis C virus antibodies in Italian blood donors. The Italian Cooperative Group.

11,117 blood donors from 24 blood transfusion services evenly distributed throughout the various Italian regions were tested for the presence of hepatitis C virus (HCV) antibodies in the serum and serum alanine aminotransferase (ALT) level. The results are as follows: (1) anti-HCV seroprevalence in Italy was 0.87% with a difference between Northern and Southern regions (0.68 vs. 1.37%) and between younger and older subjects (0.62 vs. 1.21%); (2) prevalence of elevated ALT levels was 4.74% without a North-South effect (except than for markedly elevated ALT levels); (3) anti-HCV seroprevalence was higher in subjects with elevated ALT (5.0%), with a North-South effect (2.2 vs. 9.9%) and particularly high (19.2%) in subjects with markedly elevated ALT; (4) ALT levels were elevated in 26.2% of anti-HCV positive subjects, with a North-South effect (14 vs. 40.5%).

Adult↗

The clinical importance of leukocyte depletion in regular erythrocyte transfusions.

Antilymphocyte, antigranulocyte and antiplatelet alloantibodies, T lymphocyte subsets, expression of HLA-DR antigens on T lymphocytes and NK cell function were determined in 11 homozygous beta-thalassemic children multitransfused ab initio with Erypur-filtered leukocyte-free red cell units (group A) and in 13 similar children multitransfused with standard packed red cell units (group B). No antibodies were found in group A patients, whereas 69% of group B patients were immunized. The two groups did not differ significantly with regard to the other test results. Considered together, thalassemia patients showed a percentage of T4+ cells and a NK cell function that were significantly lower than those found in a reference group of 16 healthy male blood donors. Thalassemics moreover showed a higher than normal percentage of T3+, T4+ and T8+ cells expressing HLA-DR antigens. The results indicate that leukocyte-free red cells should be the treatment of choice for prospective recipients of multiple transfusions, since they are capable of preventing (or delaying) the production of alloantibodies against leukocytes and platelets. From the data of the present study, it does not seem that the transfusion of leukocyte-free red cells is capable of preventing the abnormalities of some immunological tests that occur in some multitransfused patients. Further investigations, however, are needed to draw conclusions on this problem.

Adult↗

Preparation of leukocyte-free platelets for transfusion by filtration through cotton wool.

Filtration through Imugard filters of random platelet concentrates or platelets obtained by plateletpheresis allow the preparation of leukocyte-free platelets for transfusion. The procedure is simple and determines only a small platelet loss (less than 10%). Filtered platelets seem to function normally in vivo. The use of leukocyte-free red cell and platelet transfusions for the support of patients suffering from leukemia or aplastic anemia could prevent major complications, such as refractoriness to platelet transfusion and to bone marrow transplantation.

Blood Platelets↗

Effectiveness of red blood cells filtered through cotton wool to prevent antileukocyte antibody production in multitransfused patients.

The effectiveness of red blood cells made leukocyte-free by filtration through cotton wool to prevent the production of antileukocyte antibodies was evaluated in children suffering from Cooley's anemia. Two studies were performed: study I was carried out prospectively in two groups of non transfused patients, one group treated with leukocyte-free filtered red cells, the other with buffy-coat-free packed red cell units. Different types of antileukocyte antibodies were looked for in both groups and the results were compared. In study II the behavior of pre-existing lymphocytotoxic antibodies found in the serum of children previously transfused with standard or buffy-coat-free packed red cell units was followed after the patients had been passed to a program of transfusion with leukocyte-free filtered red cells. Study I showed that none of the patients transfused with leukocyte-free filtered red cell units have produced antileukocyte antibodies, while these could be found in 2/3 of the patients transfused with buffy-coat-free packed red cell units. Study II showed that the repeated transfusion of leukocyte-free filtered red cells to patients who possessed in their serum preformed lymphocytotoxic antibodies did not cause any increase in the potency or spectrum of these antibodies, but was in fact accompanied in some cases by their decrease or disappearance. It is concluded that filtration through cotton is an easy and inexpensive means of preparing leukocyte-free red blood cells for transfusion capable of preventing (or reducing) the production of antileukocyte antibodies in multitransfused patients.

Antilymphocyte Serum↗

An immunoenzymatic assay for the detection and quantitation of platelet antibodies: the platelet beta-galactosidase test (PGT).

An immunoenzyme assay for detection of platelet antibodies and suitable for routine use is described. Purified rabbit IgG anti-human IgG antibodies are conjugated to beta-galactosidase with meta-maleimidobenzoyl-hydroxysuccinimide ester as a bifunctional reagent and o-nitrophenyl-beta-galactopyranoside as a substrate to evaluate the enzymatic activity of the labeled antiglobulin. The sera of 26 patients suffering from various diseases (acute leukemia, aplastic anemia and systemic lupus erythematosus) and 40 control subjects were assayed with the enzyme-labeled reagent and, for comparison, with an indirect immunofluorescence technique. Half of these patients had never been transfused. Platelet antibodies were detected by both assays in all the transfused patients except one, and in 3 out of 13 non-transfused patients. The sera of all the control subjects were negative. Quantitation of platelet antibodies was obtained by a sensitive antiglobulin absorption technique. A method for standardization of the reagents allowing comparison of results obtained in the same patient at different times and suitable for long-term follow-up studies is also described.

Absorption↗