System for robotically assisted percutaneous procedures with computed tomography guidance.

We present the prototype of an image-guided robotic system for accurate and consistent placement of percutaneous needles in soft-tissue targets under CT guidance inside the gantry of a CT scanner. The couch-mounted system consists of a seven-degrees-of-freedom passive mounting arm, a remote center-of-motion robot, and a motorized needle-insertion device. Single-image-based coregistration of the robot and image space is achieved by stereotactic localization using a miniature version of the BRW head frame built into the radiolucent needle driver. The surgeon plans and controls the intervention in the scanner room on a desktop computer that receives DICOM images from the scanner. The system does not need calibration, employs pure image-based registration, and does not utilize any vendor-specific hardware or software features. In the open air, where there is no needle-tissue interaction, we systematically achieved an accuracy better than 1 mm in hitting targets at 5-8 cm from the fulcrum point. In the phantom, the orientation accuracy was 0.6 degrees, and the distance between the needle tip and the target was 1.04 mm. Experiments indicated that this robotic system is suitable for a variety of percutaneous clinical applications.

Biopsy, Needle↗

Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

PURPOSE: The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. MATERIALS AND METHODS: The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. RESULTS: The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. CONCLUSIONS: A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

Animals↗