PubMed HealthSearch

Biomedical subjects

A Pichard

Publications and source records attributed to A Pichard.

At least 19 recordsLinked to original sources

Percutaneous excimer laser coronary angioplasty: results in the first consecutive 3,000 patients. The ELCA Investigators.

OBJECTIVES: We report the comprehensive results of the first consecutive 3,000 patients treated in an excimer laser coronary angioplasty registry. BACKGROUND: Excimer laser coronary angioplasty involves the use of a pulsed, 308-nm ultraviolet laser transmitted by optical fibers to reduce coronary stenoses. Preliminary reports have described safety and efficacy profiles in small numbers of patients. METHODS: Patients were enrolled in a prospective, nonrandomized manner. The catheters used were 1.3, 1.6, 2.0, 2.2 and 2.4 mm in diameter, at energy densities up to 70 mJ/mm2. Procedures were performed by standard angioplasty technique with conventional guide catheters. RESULTS: Seventy-five percent of patients were male, 68% were in Canadian Cardiovascular Society functional class III or IV and the cohort included 3,592 lesions. Procedural success (final stenosis < or = 50% without in-hospital Q wave myocardial infarction, coronary artery bypass surgery or death) was 90% and did not differ between the first 2,000 and the last 1,000 patients treated. There was no significant difference in success or complication rates with respect to lesion length, nor were there differences between selected complex and simple lesions. Complications included in-hospital bypass surgery (3.8%), Q wave myocardial infarction (2.1%) and death (0.5%). Coronary artery perforation occurred in 1.2% of patients (1% of lesions) but significantly decreased to 0.4% in the last 1,000 patients (0.3% of lesions). Angiographic dissection occurred in 13% of lesions, transient occlusion in 3.4% and sustained occlusion in 3.1%. Comprehensive lesion morphologic data collected in the latter portion of the study showed the procedure predominantly limited to American College of Cardiology-American Heart Association type B2 and C lesions, with no significant difference in short-term outcome between groups. CONCLUSIONS: Excimer laser angioplasty can be safely and effectively applied, even in a variety of complex lesions not well suited for percutaneous transluminal coronary angioplasty. These types may include aorto-ostial, long lesions, total occlusions crossable with a wire, diffuse disease and vein grafts. Most recent data show a trend for the selection of predominantly complex lesions and a reduction in the incidence of perforation. This procedure may broaden the therapeutic window for the interventional treatment of selected complex coronary artery disease.

Angioplasty, Balloon, Coronary

Feasibility of on-line transesophageal echocardiography during balloon mitral valvulotomy: experience with 93 patients.

Percutaneous balloon mitral valvulotomy (PBMV) has become an established method of treating symptomatic patients with rheumatic mitral stenosis. PBMV is performed with fluoroscopic guidance alone in most centres. However, even experienced operators can be misled by radiographic anatomic landmarks. Transesophageal echocardiography (TEE) provides high-quality images of the atrial septum, left atrium, mitral valve, and surrounding structures and has a number of unique advantages that make it a useful adjunct to fluoroscopy for guidance and monitoring of patients during PBMV. The aim of this study was to demonstrate the feasibility, safety, and utility of on-line TEE during PBMV on awake patients. TEE was performed on 93 consciously sedated, awake patients in the cardiac catheterisation laboratory during PBMV. Ninety five patients were successfully intubated in the supine position. Two patients were excluded from PBMV based on mobile thrombi near the mouth of the left atrial appendage. The TEE was well-tolerated in the 93 patients who underwent PBMV, and no complications of TEE were detected. Major complications of PBMV were detected in 7 patients (severe MR, n = 3; tamponade, n = 1; large ASD, n = 3). We conclude that on-line TEE during PBMV is feasible, safe, and well tolerated. TEE-guidance facilitates transseptal catheterization and proper positioning of balloon catheters across the mitral orifice. TEE can help monitor the adequacy of PBMV and help decide whether or not subsequent dilatations are necessary. TEE can rapidly detect complications and thereby guide appropriate management of these complications.

Adolescent

Probe "balloon on a wire" ultra-low-profile coronary catheter: results of PTCA in 107 patients.

A new low-profile "balloon-on-a-wire" angioplasty catheter, the Probe (USCI), was used in 107 patients over a 4-month period. Twenty-nine patients had stable angina, 59 had unstable angina, and 19 had had myocardial infarction (MI) 3 to 15 days prior to the procedure; 71 patients had single-vessel and 36 had multi-vessel disease. In this series, 57 lesions were defined as complex. Successful dilatation was defined as a residual stenosis of less than 30%. Of 132 non-total obstructions, 127 (97%) were successfully dilated. Two distal lesions could not be reached, two lesions could not be crossed by the balloon, and a distal lesion dilatation resulted in acute closure in one case. Of 19 total obstructions, 16 (84%) were successfully dilated (mean residual stenosis 23%). The wire tip was unable to cross the lesion in the three unsuccessful procedures. Seven complications occurred in the series, all involving non-total obstructions: closure of a distal vessel and a side branch caused no clinical symptoms or EKG changes; three local dissections were tacked back with repeat dilatation; and two longitudinal dissections caused no apparent reduction in luminal diameter. The Probe's low-profile and exceptional trackability enabled it to cross very tight lesions with minimal trauma to the vessel wall. The high degree of conformability of the PET balloon minimizes vessel straightening or sheer forces and appears to reduce the potential for dissection. The device may therefore extend the indications and ease of PTCA while reducing complications of the procedure.

Angiography

Correlation of coronary angioscopic to angiographic findings in coronary artery disease.

An Olympus ultrathin fiberscope, 1.8 mm outer diameter, was inserted intraluminally into 11 stenoses of the left anterior descending and circumflex coronary arteries in 8 patients at coronary bypass surgery. Intraluminal views were obtained by coupling the angioscope to a color video camera and videotape recorder, and compared with preoperative coronary angiographic findings in right and left anterior oblique views. Atherosclerotic plaque was observed as yellow-white mass attached onto the luminal lining, which may be large enough to virtually obliterate the vascular lumen. Angioscopy provided a topographic view and cross-sectional picture of stenosis not observed by angiography. Single-plane angioscopic cross-sectional stenotic lumens correlated well (r = 0.90, p less than 0.001) with calculated angiographic luminal narrowings. However, with subtotal obstruction, lesion length must be assessed angiographically. Coronary angioscopy can be a useful adjunct to angiography by providing the added dimension of the true cross-sectional view of obstruction.

Coronary Angiography

Acute effect of systemic versus intracoronary dipyridamole on coronary circulation.

Dipyridamole has been proposed as an ideal agent to evaluate coronary vascular reserve because it produces selective coronary vasodilation without systemic hemodynamic effect. The actions of intracoronary (IC) and intravenous (IV) dipyridamole on coronary blood flow and systemic hemodynamics were compared in 15 patients with chest pain syndrome and normal coronary arteries. They received IC dipyridamole, followed 10 minutes later by 0.5 mg/kg of IV dipyridamole. IC dipyridamole produced a 73% increase in coronary sinus flow without hemodynamic changes, except for a slight increase in pulmonary systolic and diastolic pressures. IV dipyridamole administration produced an additional 88% increase in coronary sinus flow, reaching 172% over baseline; it was also associated with a significant (p less than 0.01) increase in heart rate (78 +/- 14 vs 102 +/- 19 beats/min), cardiac index (4 +/- 0.7 vs 6.3 +/- 1.7 liters/min/m2), and pulmonary artery systolic (27 +/- 5 vs 34 +/- 7 mm Hg) and diastolic pressures (12 +/- 4 vs 19 +/- 7 mm Hg). These data suggest that the coronary vasodilatory effect seen after IV dipyridamole administration is related to mechanisms other than direct coronary vasodilation.

Adult

Cardiac tamponade following percutaneous transluminal coronary angioplasty: four case reports.

Percutaneous transluminal coronary angioplasty (PTCA) has had complications related to dilating catheters and guide wires such as coronary artery dissection, spasm, rupture, and perforation. This report describes four patients who developed cardiac tamponade following PTCA, presumably from right ventricular (RV) perforation. All four received large doses of heparin during PTCA and three received antiplatelet therapy. In three cases, cardiac tamponade occurred several hours after PTCA. All patients did well following operative intervention and no patient required repair of a cardiac perforation. We postulate that impaired hemostasis in the presence of an otherwise inconsequential RV perforation causes tamponade. Three alternatives to provide standby pacing are proposed.

Adult

Acute coronary hemodynamic response to cigarette smoking in patients with coronary artery disease.

The acute changes in coronary blood flow and coronary resistance that occur in response to cigarette smoking have not been accurately determined. To define the factors that affect this response, coronary sinus blood flow was measured in 16 patients (group I) with coronary artery disease and in 6 patients (group II) without angiographically detectable coronary disease. Seven patients (group IA) had severe (greater than or equal to 75%) proximal left coronary lesions and nine patients (group IB) had significant distal lesions with 50% or less proximal stenoses. Group I had a smaller overall increase (increases 1.6 +/- 5.3%) in coronary sinus blood flow than did group II (increases 7.7 +/- 6.1%) (p less than 0.05). Coronary resistance increased overall (increases 2.7 +/- 5.3%) in group I but decreased (decreases 2.4 +/- 3.4%) in group II (p less than 0.05). Patients in group IA had a highly significant increase in coronary resistance as compared with group IB (increases 7.0 +/- 4.2% versus decreases 0.9 +/- 2.6%) (p less than 0.001). Coronary sinus flow tended to decrease (decreases 1.2 +/- 4.6%) in group IA but to increase (increases 3.8 +/- 5.1%) in group IB (p = 0.06). It is concluded that smoking increases coronary resistance in patients with coronary artery disease. A greater impact is observed in patients with a severe proximal stenosis than in those with a distal stenosis. It is proposed that smoking increases coronary artery tone at the site of the stenosis, limiting the coronary flow response proportionally to the size of the affected vascular bed.

Adult