PubMed Health⌕ Search

Biomedical subjects

A Pierangeli

Publications and source records attributed to A Pierangeli.

At least 19 recordsLinked to original sources

Markers of human papillomavirus infection and their correlation with cervical dysplasia in human immunodeficiency virus-positive women.

Human papillomavirus (HPV) genotypes and HPV DNA load were analysed in cervical smears from 76 human immunodeficiency virus (HIV)-positive and 54 HIV-negative women. The prevalence of genotypes was similar for all women, with the exception of HPV62, which was over-represented in HIV-positive samples. HIV-positive women showed a higher prevalence of multiple genotypes that correlated neither with CD4(+) T-cell counts nor with cervical dysplasia. No significant differences were observed in terms of total or single-type HPV DNA load. The HPV DNA load in both HIV-positive and HIV-negative women was significantly higher in squamous intra-epithelial lesions than in negative Pap smears.

Adult↗

Identification of human papilloma viruses in male dysplastic genital lesions.

The association of Human Papillomaviruses (HPV) DNA with female genital lesions has been widely documented whereas little has been reported about male genital pathologies. The aim of this work was to investigate the presence of HPV DNA and the genotype involved in male dysplastic genital lesions. All samples were analysed by polymerase chain reaction (PCR) to amplify HPV E1 and L1 genes. The PCR products were subjected to restriction fragment length polymorphism (RFLP) to determine the HPV genotype. We analysed 209 male genital biopsies from different lesions: mostly from acuminate condylomata and from Buschke-Lowenstein tumours, Bowen papulosis, leukoplakia of the glans, scrotal lymphangioma, penile horn and penile/perianal verrucous carcinoma. Our results revealed the constant presence of viral DNA in genital condylomata, mainly associated with low risk HPV; the presence of the same genotypes was also detected in some of the examined rare pathologies.

Adult↗

Usefulness of transesophageal echocardiographic monitoring to improve the outcome of stent-graft treatment of thoracic aortic aneurysms.

The stent-graft procedure is becoming an alternative to surgery for treatment of many diseases of the descending thoracic aorta. This study evaluated the role of transesophageal echocardiography (TEE), used in combination with fluoroscopy and angiography, in monitoring the outcome of stent-graft placement. Twenty-two consecutive patients were submitted to stent-graft positioning in the descending aorta for various pathologies (7 patients had type B aortic dissections, 6 had thoracic aneurysms, 2 had thoraco-abdominal aneurysms, and 7 had post-traumatic aortic aneurysms). Before stent-graft deployment, TEE changed the proximal site of stent positioning initially identified by angiography in 33% of patients (5 of 15) with aortic aneurysms because of calcifications or atheromas that could interfere with stent adhesion to the aortic wall and that were not seen on angiography. In 28% of patients (2 of 7) with aortic dissection, TEE showed the guidewire in the false lumen, allowing an immediate repositioning. After stent-graft deployment, color Doppler TEE showed a perigraft leak in 7 patients, whereas angiography detected a perigraft leak in only 2 patients (p = 0.02). In 4 of these patients, further balloon expansions resulted in resolution of the leak. In the remaining 3 patients, additional stent-graft positioning was necessary. Considering the total patient cohort, TEE yielded relevant information, resulting in procedure changes in 59% (13 of 22). In conclusion, TEE provided additional information with respect to angiography in all phases of stent-graft treatment, improving immediate outcome and reducing complications.

Adult↗

Antegrade selective cerebral perfusion during surgery of the thoracic aorta: risk analysis.

OBJECTIVE: To determine independent predictors of neurologic outcome and hospital mortality after surgery of the thoracic aorta using moderate hypothermic circulatory arrest and antegrade selective cerebral perfusion. METHODS: Between November 1996 and June 2000, 96 consecutive patients (69 men, 27 women; mean age 63+/-10 years) underwent operations on the thoracic aorta with the aid of moderate hypothermic circulatory arrest and antegrade selective cerebral perfusion. Sixty-four patients were operated on electively (66.7%), 32 emergently (33.3%). Indications for surgery were: type A acute dissection in 30 patients (31.3%), chronic aneurysm in 66 (68.8%). Seventeen patients (17.7%) had undergone previous aortic/cardiac surgical procedures. The mean selective cerebral perfusion time was 52.2+/-31.9 min (range, 18-220 min). Preoperative, intraoperative, and postoperative factors were analyzed by univariate and multivariate analysis to identify predictors of hospital mortality and neurologic outcome. RESULTS: There were no operative deaths; the hospital mortality rate was 11.5% (11/96). Stepwise logistic regression revealed preoperative renal dysfunction (P=0.021), type A acute dissection (P=0.053), coronary artery bypass grafting (P=0.058), post-operative pulmonary complications (P=0.000) and repeat thoracotomy for bleeding (P=0.027) as independent predictors of hospital mortality. One patient sustained a permanent neurologic deficit (1%). Transient neurologic deficit occurred in eight patients (8.3%). Coronary artery bypass grafting (P=0.013), and postoperative cardiac complications (P=0.049) were statistically associated with an increased risk of any (transient and permanent) neurologic dysfunction on univariate analysis. Stepwise logistic regression indicated coronary artery bypass grafting as independent factor for any neurologic dysfunction. CONCLUSION: This study confirmed that selective cerebral perfusion is an effective method of cerebral protection allowing complex thoracic aorta operations to be performed with low risk of hospital mortality and adverse neurologic outcome. We didn't find that the duration of selective cerebral perfusion time influence hospital mortality and any neurologic deficit.

Adult↗

Clinical evaluation of St Jude Medical Hemodynamic Plus versus standard aortic valve prostheses: The Italian multicenter, prospective, randomized study.

OBJECTIVE: Hemodynamic and clinical performances of 21-mm and 23-mm St Jude Medical Hemodynamic Plus aortic valves (St Jude Medical, Inc, St Paul, Minn) were compared with those of 21-mm and 23-mm St Jude Medical standard cuff aortic valves in the first such multicenter, prospective, randomized study. Hemodynamic Plus valves are mechanical, bileaflet prostheses suitable for the small aortic anulus. METHODS: Patients with 21-mm and 23-mm anulus diameters were randomized to receive either a Hemodynamic Plus or a standard cuff valve. Postoperatively and at 6 months after the operation, patients underwent 2-dimensional Doppler echocardiography. Ejection fraction, cardiac output, peak gradient, mean gradient, effective orifice area, effective area index, and performance index were calculated. Postoperative and 6-month echocardiographic measurements and their variations across observation times were analyzed statistically. RESULTS: Of the 140 patients enrolled, 5 died at operation and 1 died of aortic dissection during the follow-up period. Eight patients were lost to follow-up. A total of 125 patients completed the study. In 1 patient a sewing cuff escaped intraoperatively. At 6 months the 21-mm and 23-mm Hemodynamic Plus valves showed significantly lower peak gradients and mean gradients than those of the 21-mm and 23-mm standard cuff valves. The 21-mm Hemodynamic Plus valves had gradients similar to those of the 23-mm Hemodynamic Plus valves. The effective orifice area did not differ significantly between the Hemodynamic Plus and standard cuff valves at either measurement. No valve mismatch was found in the 4 groups of patients. A more enhanced decrease of peak gradients and mean gradients and a more enhanced increase of effective orifice areas, effective area indices, and performance indices were found across observation times for patients with Hemodynamic Plus valves compared with those with standard cuff valves. CONCLUSIONS: Clinical hemodynamic performances of 21-mm and 23-mm St Jude Medical Hemodynamic Plus valves correspond closely with those of standard cuff valves, and gradients are substantially better than those of standard cuff valves of the same diameter. Therefore, use of this valve may minimize the need for aortic anulus enlargement. Early follow-up results with the Hemodynamic Plus valves were excellent, although more time is required to confirm this outcome.

Aortic Valve↗

Haemolysis during cardiopulmonary bypass: how to reduce the free haemoglobin by managing the suctioned blood separately.

During cardiopulmonary bypass (CPB) the collection of the patient's blood from the operating area is of fundamental importance. This blood is collected in the cardiotomy reservoir using field suckers and can be managed in different ways. It can be filtered in the cardiotomy reservoir and redirected to the venous reservoir, then oxygenated and returned to the patient, or it can be managed separately: collected in the cardiotomy reservoir, treated at the end of the operation and only after this, returned to the patient. The aim of this study is to determine in vivo the effect of a separate management of the suction blood from the operative field, using the Avant D903 oxygenator (Dideco, Mirandola, Italy). Twenty-one patients undergoing coronary artery bypass graft surgery with CPB were selected and put into two groups at random. In the control group (n = 10) the suction blood in the cardiotomy reservoir was filtered and immediately redirected into the venous reservoir, oxygenated and returned to the patient. In the study group (n = 11) the suctioned blood was collected in the D903 Avant's (Dideco) cardiotomy reservoir and returned to the patient only after having been washed at the end of the operation, using a Compact Advanced (Dideco), as required. Clinical data demonstrated that while in the study group it was possible to keep the free plasma haemoglobin (FPH) concentrations the same as at the beginning, in the control group there was a significant increase in FPH from 5.0 +/- 3.5 mg/dl (baseline) to 37 +/- 16.7mg/dl (120min after CPB).

Aged↗

Surgical treatment of secundum atrial septal defect in patients older than 50 years.

BACKGROUND: The aim of this study was to verify if surgery is beneficial for patients older than 50 years. METHODS: Sixty-five patients older than 50 years were operated for a secundum atrial septal defect between November 1974 and November 1998. Preoperative data were obtained from hospital records; postoperative data from written questionnaires or direct telephone interviews. A comparison of pre and postoperative data was possible in 53 patients. RESULTS: The operative mortality was 0%. One patient died of a thromboembolic complication 32 days after surgery. The mean follow-up was 9 +/- 6 years. After surgery, clinical improvement occurred in 22 patients (41.5%) with the majority of them (69.8%) being asymptomatic or only mildly symptomatic. The occurrence of atrial fibrillation/flutter did not decrease after surgery (39.6 vs 26.4%). A thromboembolic event occurred in 2 patients before surgery and in 2 patients postoperatively; all of them had supraventricular arrhythmias and were not taking anticoagulants. CONCLUSIONS: Surgical closure of atrial septal defects in patients older than 50 years is feasible. The mortality is low. In this age group, surgery has a beneficial effect on the clinical status of the patients but not on the occurrence of supraventricular arrhythmias that can affect morbidity and mortality in patients who are not treated with anticoagulants.

Age Factors↗

Aortico-left ventricular tunnel: two new cases with a long-term follow-up.

Aortico-left ventricular tunnel is a rare congenital communication between the ascending aorta and the left ventricle. Its hemodynamic effect is severe aortic incompetence. Surgery is the only treatment and should be performed before aortic incompetence or ventricular dilation develops. Two neonates with aortico-left ventricular tunnel were operated on at our institution, with closure of the aortic end of the tunnel with a Gore-Tex patch. The 2 patients were discharged in good conditions, and at 112 and 42-month follow-up respectively they are in good health, without medication and with a normal echocardiographic pattern. Aortico-left ventricular tunnel should be treated surgically as soon as possible in order to prevent any damage to the aortic valve and the left ventricle. The operative risk is not low, but results are very encouraging.

Aortic Valve↗

Evolution of aortic dissection after surgical repair.

Patients after aortic dissection repair still have long-term unfavorable prognosis and need careful monitoring. The purpose of this study was to analyze the evolution of aortic dissection after surgical repair in correlation to anatomic changes emerging from systematic magnetic resonance imaging (MRI) follow-up. Between January 1992 and June 1998, 70 patients underwent surgery for type A aortic dissection. Fifty-eight patients were discharged from the hospital (17% operative mortality) and were followed by serial MRI for 12 to 90 months after surgery. In all, 436 postoperative MRI examinations were analyzed. In 13 patients (22.5%) no residual intimal flap was identified, whereas 45 patients (77.5%) presented with distal dissection, with a partial thrombosis of the false lumen in 24. The yearly aortic growth rate was maximum in the descending aortic segment (0.37 +/- 0.43 cm) and was significantly higher in the absence of thrombus in the false lumen (0.56 +/- 0.57 cm) (p <0.05). There were 4 sudden deaths, with documented aortic rupture in 2. Sixteen patients underwent reoperation for expanding aortic diameter. In all but 1 patient, a residual dissection was present (in 13 without any thrombosis of the false lumen). Close MRI follow-up in patients after dissection surgical repair can identify the progression of aortic pathology, providing effective prevention of aortic rupture and timely reoperation. Thrombosis of the false lumen appears to be a protective factor against aortic dilation.

Adult↗

Antegrade selective cerebral perfusion during operations on the thoracic aorta: our experience.

BACKGROUND: Various methods of cerebral protection have been used during aortic arch operations. Deep hypothermia with circulatory arrest is the most common technique but has a limited safe period for circulatory arrest. Selective cerebral perfusion has been introduced to prolong this safe period. We reviewed our experience with antegrade selective cerebral perfusion during surgical repair of the thoracic aorta. METHODS: Between November 1996 and December 1998, 57 consecutive patients were operated on for aortic arch aneurysms using selective cerebral perfusion. Forty-one were men (71.9%), and 16 were women. The mean age was 63.2 years. Thirty-seven patients had chronic aneurysms, and 20 had type A acute dissection. Preoperative, intraoperative, and postoperative factors were analyzed by univariate and multivariate analysis to identify predictors of early mortality and transient neurologic dysfunction. RESULTS: There were no permanent neurologic deficits. The early mortality rate was 8.8% (5 patients). Multivariate analysis revealed preoperative renal failure (p = 0.0338) and repeat thoracotomy for bleeding (p = 0.0201) to be independent risk factors for early mortality. The factor postoperative cardiac complications (p = 0.0368) was the only independent predictor of transient neurologic dysfunction, and it occurred in 3 patients (5.3%). CONCLUSIONS: The present study confirmed that preoperative renal failure and repeat thoracotomy for bleeding are significant predictors of mortality in aortic arch operations using selective cerebral perfusion and that cerebral perfusion time has no influence on the postoperative outcome. We believe that selective cerebral perfusion is an optimal technique of cerebral protection during operations on the aortic arch.

Aortic Aneurysm, Thoracic↗

Delayed treatment of isthmic aortic rupture.

Traumatic rupture of the thoracic aorta is a life-threatening injury with a high mortality, and is difficult to manage in polytraumatized patients. Between 1980 and 1998, 50 patients were admitted to our Department with acute traumatic aortic rupture (TAR). The site of lesion was usually isthmic (86% of patients). From 1980 to 1992, 21 patients (Group I) underwent emergency surgical repair; from 1992 to January 1998, 29 patients (Group II) underwent intensive medical treatment, except one who was haemodynamically unstable and died 8h after the trauma from a massive haemothorax before an emergency thoracotomy could be attempted. The aortic rupture was followed up by MRI or CT scan. Twenty-one patients in Group II underwent aortic repair an average of 8.6 months after the injury. In two patients the operation was expedited because of an enlarging aortic aneurysm. In Group I the postoperative mortality was 19%, three patients developed postoperative paraplegia and one acute renal failure. In Group II there were no postoperative deaths and no major complications.

Adult↗

Primary endoleakage in endovascular treatment of the thoracic aorta: importance of intraoperative transesophageal echocardiography.

OBJECTIVES: Endovascular treatment of the thoracic aorta has developed as an efficacious alternative to open surgical repair. However, despite the high primary success rate, perigraft leakage constitutes the major concern in long-term follow-up. Endoleaks are widely reported both in abdominal and thoracic endovascular series and are usually identified by intraoperative angiography. Transesophageal echocardiography is a sensitive imaging technique in the evaluation of aortic diseases, widely used to monitor cardiac surgery. The aim of this study was to evaluate the efficacy of transesophageal echocardiography in leakage detection during endovascular stent procedures of the thoracic aorta. METHODS: Intraoperative transesophageal echocardiography was used in conjunction with angiography in 25 patients subjected to endovascular stent treatment of the descending thoracic aorta. Spiral computed tomographic scanning was performed before discharge and 3, 6, and 12 months after treatment. RESULTS: Information from transesophageal echocardiography was relevant in the selection of the landing zone in 62% of cases. In 8 patients, transesophageal echocardiography with color Doppler sonography showed a perigraft leak, 6 of which were not visible on angiography, suggesting the need for further balloon expansion or graft extension. Postoperative computed tomographic scanning in the 25 patients showed 1 endoleak, which sealed spontaneously. At 3 months, computed tomographic examination confirmed the absence of perigraft leakage in all patients. CONCLUSIONS: During implantation of a stent-graft in the descending thoracic aorta, transesophageal echocardiography provides information in addition to that provided by angiography, improving immediate and late procedural results.

Adult↗

Inhibition of cap-dependent gene expression induced by protein 2A of hepatitis A virus.

The viral protein 2A of hepatitis A virus (HAV) lacks the conserved 18 aa sequence found in other picornavirus proteases; hence, it is unclear whether the induction of CPE by culture-adapted HAV strains is due to 2A-mediated activity. Moreover, the cleavage sites and actual borders of HAV 2A are not known. Accordingly, a nested series of cDNA sequences encoding the segment of the HAV polyprotein (aa 760-1087) were linked to the 5'-UTR of poliovirus type 2 (Lansing strain) and inserted downstream of the gene encoding human growth hormone (GH). Following transfection of COS-1 cells, levels of GH (translation of which was entirely cap dependent) were determined in culture supernatants. Expression of HAV peptides extending from aa 764, 776 or 791 to 981 strongly inhibited cap-dependent translation of GH, whereas cap-independent expression of a reporter gene (CAT) directed by the poliovirus RNA 5'-UTR was unaffected. The inhibitory effect was absent in constructs expressing either the short peptide encompassing aa 760-836 or proteins initiated downstream of the putative cleavage site 836-837, suggesting that the boundaries of a functional HAV 2A may extend from the Gln/Ser junction 791-792 to residue 981, while peptides initiated at the Gln/Ala pair 836-837 may result from alternative cleavage. Point mutations that substituted members of the triad Ser(916), His(927) and Asp(931) abolished the inhibitory effect on cap-dependent translation, suggesting that the HAV-induced CPE may be mediated by 2A protein.

5' Untranslated Regions↗

Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.

BACKGROUND: The treatment of thoracic aortic dissection is guided by prognostic and anatomical information. Proximal dissection requires surgery, but the appropriate treatment of distal thoracic aortic dissection has not been determined, because surgery has failed to improve the prognosis. METHODS: We prospectively evaluated the safety and efficacy of elective transluminal endovascular stent-graft insertion in 12 consecutive patients with descending (type B) aortic dissection and compared the results with surgery in 12 matched controls. In all 24 patients, aortic dissection was diagnosed by magnetic resonance angiography. In each group, the dissection involved the aortic arch in 3 patients and the descending thoracic aorta in all 12 patients. With the patient under general anesthesia, either surgical resection was undertaken or a custom-designed endovascular stent-graft was placed by unilateral arteriotomy. RESULTS: Stent-graft placement resulted in no morbidity or mortality, whereas surgery for type B dissection was associated with four deaths (33 percent, P=0.09) and five serious adverse events (42 percent, P=0.04) within 12 months. Transluminal placement of the stent-graft prosthesis was successful in all patients, with no leakage; full expansion of the stents was ensured by balloon inflation at 2 to 3 atm. Sealing of the entry tear was monitored during the procedure by transesophageal ultrasonography and angiography, and thrombosis of the false lumen was confirmed in all 12 patients after a mean of three months by magnetic resonance imaging. There were no deaths or instances of paraplegia, stroke, embolization, side-branch occlusion, or infection in the stent-graft group; nine patients had postimplantation syndrome, with transient elevation of C-reactive protein levels and body temperature plus mild leukocytosis. All the patients who received stent-grafts recovered, as did seven patients who underwent surgery for type B dissection (58 percent) (P=0.04). CONCLUSIONS: These preliminary observations suggest that elective, nonsurgical insertion of an endovascular stent-graft is safe and efficacious in selected patients who have thoracic aortic dissection and for whom surgery is indicated. Endoluminal repair may be useful for interventional reconstruction of thoracic aortic dissection.

Adult↗

Protective effect of low frequency low energy pulsing electromagnetic fields on acute experimental myocardial infarcts in rats.

This series of experiments assesses the effect of exposure to low-frequency pulsing electromagnetic fields (PEMFs) in 340 rats with acute experimental myocardial infarcts. The left anterior descending artery was ligated with suture thread, and the rats underwent total body exposure to PEMFs until they were killed. Twenty-four hours after surgery, the necrotic area was evaluated by staining with triphenyltetrazolium chloride. A significant reduction of the necrotic area was observed in the animals exposed to PEMFs compared with the nonexposed controls. Exposure for up to 6 days does not appear to affect the area of necrosis, although in exposed animals an increase of vascular invasion of the necrotic area is observed: 24.3 % as against 11.3 % in controls. No effect on the necrotic area size from exposure was found when the left anterior descending artery was occluded for 60 min, followed by reperfusion. The results reported show that exposure to PEMFs is able to limit the area of necrosis after an acute ischemic injury caused by permanent ligation of the left anterior descending artery. These data are in agreement with the protective effect of PEMFs observed on acute ischemia in skin free flaps in rats and in cerebral infarcts in rabbits.

Animals↗