A preliminary dosimetric characterization of chemical vapor deposition diamond detector prototypes in photon and electron radiotherapy beams.

Three radiation detectors based on polycrystalline diamond films with different thickness and resistivity, obtained by microwave chemical vapor deposition, were tested to assess their suitability for relative dosimetry of photon and electron beams supplied by clinical linear accelerators. All samples showed a linear response as a function of the absorbed dose. The sensitivity per unit of detector sensitive volume spanned between 7 and 43 nC Gy(-1) mm(-3) with an applied electric field of 40 kV/cm. The dose rate dependence was evaluated following the Fowler theory and delta coefficient values between 0.95 and 1.00 were found for the three samples when polarized at 40 kV/cm. Percentage depth dose curves, output factors, and normalized dose profiles were determined for 6 and 10 MV photon beams and for 6 and 15 MeV electron beams. The results obtained with the diamond detectors were in good agreement with those obtained by reference detector measurements [all the data were within the experimental uncertainty of 1% (1sigma)].

Crystallization↗

Dosimetric characterization of a large area pixel-segmented ionization chamber.

A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes and large gradients. The detector was characterized in a PMMA phantom using 60Co and 6 MV x-ray photon beams. It has shown good signal linearity with respect to dose and dose rate to water. The average sensitivity of a single ionization chamber was 2.1 nC/Gy, constant within 0.5% over one month of daily measurements. Charge collection efficiency was 0.985 at the operating polarization voltage of 400 V and 3.5 Gy/min dose rate. Tissue maximum ratio and output factor have been compared with a Farmer ionization chamber and were found in good agreement. The dose profiles have been compared with the ones obtained with an ionization chamber in water phantom for the field sizes supplied by a 3D-Line dynamic multileaf collimator. These results show that this detector can be used for 2D dosimetry of x-ray photon beams, supplying a good spatial resolution and sensibly reducing the time spent in dosimetric verification of complex radiation fields.

Algorithms↗

The wall correction factor for a spherical ionization chamber used in brachytherapy source calibration.

The effect of wall chamber attenuation and scattering is one of the most important corrections that must be determined when the linear interpolation method between two calibration factors of an ionization chamber is used. For spherical ionization chambers the corresponding correction factors A(w) have to be determined by a non-linear trend of the response as a function of the wall thickness. The Monte Carlo and experimental data here reported show that the A(w) factors obtained for an Exradin A4 chamber, used in the brachytherapy source calibration, in terms of reference air kerma rate, are up to 1.2% greater than the values obtained by the linear extrapolation method for the studied beam qualities. Using the Aw factors derived from Monte Carlo calculations, the accuracy of the calibration factor N(K,Ir) for the Exradin A4, obtained by the interpolation between two calibration factors, improves about 0.6%. The discrepancy between the new calculated factor and that obtained using the complete calibration curve of the ion-chamber and the 192Ir spectrum is only 0.1%.

Algorithms↗

Experimental dosimetry of a 32P catheter-based endovascular brachytherapy source.

The experimental dosimetry in a water phantom of a 32P linear source, 20 mm in length, used for the brachytherapy of coronary vessels is reported. The source content activity, A, was determined by means of a calibrated well ion-chamber and the value was compared with the contained activity reported in the manufacturer's certification. In this field of brachytherapy dosimetry, radiochromic film supplies a high enough spatial resolution. A highly sensitive radiochromic film, that presents only one active layer, was used in this work for the source dosimetry in a water phantom. The radiochromic film was characterized by electron beams produced by a clinical linac. A Monte Carlo calculation of beta spectra in water at different distances along the source transverse bisector axis allowed to take into account the low dependence of film response from the electron beam energy. The adopted experimental set-up, with the source in its catheter positioned on the film plane inside the water phantom, supplies accurate dosimetric information. The measured dose rate to water per unit of source activity at reference distance, D(r0, theta0)/A, in units of cGy s(-1) GBq(-1), was in agreement with the value reported in the manufacturer's certification within the experimental uncertainty. The radial dose function, g(r), is in good agreement with the literature data. The anisotropy function F(r, theta) is also reported. The analysis of the dose profile obtained at 2 mm from the source longitudinal axis shows that the uniformity is within 10% along 75% of the 20 mm treatment length. The adopted experimental set-up seems to be adequate for the quality control procedure of the dose homogeneity distribution in the water medium.

Algorithms↗

A standard dosimetry procedure for 192Ir sources used for endovascular brachytherapy.

The experimental dosimetry of a high dose rate (HDR) 192Ir source used for the brachytherapy of peripheral vessels is reported. The direct determination of the reference air kerma rate Kr agrees, within the experimental uncertainty, with the results obtained by a well ionization chamber calibrated at the NIST and the manufacturer's certification. A highly sensitive (HS) radiochromic film (RCF), that presents only one active layer, was used for the source dosimetry in a water phantom. The adopted experimental set-up, with the source in its catheter positioned on the RCF plane, seems to have given better accuracy of the RCF optical density measurements. The agreement between the measurement of the dose rate constant DKr (10 mm, pi/2) and the literature data confirmed the coherence of the HS RCF calibration obtained by the kerma in air measurements. The RCF measurements supplied dosimetric information about the dose to water per reference air kerma rate D(r, theta)/Kr along the source transverse bisector axis, the radial dose function g(r) and the anisotropy function F(r, theta). The value D(2 mm, pi/2)/Kr = 22.4 +/- 1.2 cGy h(-1)/(microGy h(-1)) is supplied with a dose uncertainty that is essentially due to the indeterminacy of the source position in the catheter. The data of the radial and anisotropy functions have been compared with Monte Carlo determinations reported in the literature.

Anisotropy↗

Characteristics of silicon and diamond detectors in a 60 MeV proton beam.

The calibration factor variation for a PTW natural diamond detector and a Scanditronix p-type stereotactic silicon diode (designed for use in photon beams) was studied in the 10-59 MeV range. Irradiations were performed in a water phantom with the 60 MeV ocular therapy beam at the CCO (UK). The diamond detector showed a sensitivity increase with energy, underestimating the dose by about 18% at the Bragg peak, by 7% at the centre and by 17% at the distal end of the SOBP region. The silicon diode did not show any significant sensitivity change with energy. However, a decrease in response of 24% was observed for an accumulated dose of 300 Gy.

Calibration↗

A correction method for diamond detector signal dependence with proton energy.

Small dosimeters as solid state detectors can be useful for the dosimetric characterization and periodic quality control of radiotherapy proton beams. The calibration of solid state detectors for proton beams is not a solved problem especially for ophthalmologic proton beams, where these detectors present a LET-dependent signal. In this work a PTW diamond detector has been selected because of its good signal reproducibility (0.3%) and stable response with accumulated dose. A method that takes into account the LET dependence of the diamond detector signal, at 62 MeV proton beam, is here proposed. In particular an empirical correction factor, kDD(Eo) (Rres), has been determined as a function of the residual range quality index, to correct the diamond detector signal for a proton beam of incident effective energy E0= 62 MeV. A dedicated software allows us to use the diamond detector as an on-line reference dosimeter, where an ionization chamber may be difficult to use, or for periodic quality control procedures. The article also reports a comparison between the signal dependence on proton energy of silicon, diamond, and radiochromic film detectors.

Biophysical Phenomena↗

Bayesian estimation of relaxation times T(1) in MR images of irradiated Fricke-agarose gels.

The authors present a novel method for processing T(1)-weighted images acquired with Inversion-Recovery (IR) sequence. The method, developed within the Bayesian framework, takes into account a priori knowledge about the spatial regularity of the parameters to be estimated. Inference is drawn by means of Markov Chains Monte Carlo algorithms. The method has been applied to the processing of IR images from irradiated Fricke-agarose gels, proposed in the past as relative dosimeter to verify radiotherapeutic treatment planning systems. Comparison with results obtained from a standard approach shows that signal-to noise ratio (SNR) is strongly enhanced when the estimation of the longitudinal relaxation rate (R1) is performed with the newly proposed statistical approach. Furthermore, the method allows the use of more complex models of the signal. Finally, an appreciable reduction of total acquisition time can be obtained due to the possibility of using a reduced number of images. The method can also be applied to T(1) mapping of other systems.

Bayes Theorem↗

Dosimetric characterization of silicon and diamond detectors in low-energy proton beams.

The dosimetric behaviour of a Scanditronix p-type silicon diode and a PTW natural diamond detector was studied in low-energy proton beams in the 8.3-21.5 MeV range. The properties investigated were linearity, reproducibility, dose rate dependence, energy and linear energy transfer (LET) dependence. The influence of detector thickness on the results of depth dose measurements was also demonstrated. A Markus parallel plate ionization chamber was used for reference dosimetry. Silicon diode and diamond detectors showed linearity at therapeutic dose level, reproducibility better than 1% (1sigma) and sensitivity variation with dose rate and proton energy.

Diamond↗

The saturation loss for plane parallel ionization chambers at high dose per pulse values.

The use of plane parallel ionization chambers with electron beams with high dose per pulse entails dose uncertainties due to the overestimation of the ion recombination factor, k, up to 20% if conventional dosimetric protocols are used. In this work MD-55-2 radiochromic films have been used as reference dosimeters to obtain dose to water per pulse DGAF(w) values for three Novac7 (Hitesys) electron beams of E0 = 5.8 MeV. However, the beam calibration by MD-55-2 films is time consuming and the use of plane parallel chambers is fundamental for a periodic quality control procedure. Three plane parallel chambers have been used and the general formula for the k determination has been tested using the calibration doses, DGAF(w). In particular, consistent ion recombination factors ksat(V0) (with the ion chamber polarized at V0), that follow the Boag theory, have been estimated at different dose per pulse values for the three plane parallel ionization chambers. This means that at present any ion chamber needs a specific ksat (V0) determination by using a reference dosimeter for which the response is independent of the dose rate. An accurate determination of ksat(V0), using a reference quality beam, can be used to determine the dose to water per pulse for electron beams of different quality and geometrical configuration.

Dose-Response Relationship, Radiation↗

PTW-diamond detector: dose rate and particle type dependence.

In this paper the suitability of a PTW natural diamond detector (DD) for relative and reference dosimetry of photon and electron beams, with dose per pulse between 0.068 mGy and 0.472 mGy, was studied and the results were compared with those obtained by a stereotactic silicon detector (SFD). The results show that, in the range of the examined dose per pulse the DD sensitivity changes up to 1.8% while the SFD sensitivity changes up to 4.5%. The fitting parameter, delta, used to correct the dose per pulse dependence of solid state detectors, was delta = 0.993 +/- 0.002 and delta = 1.025 +/- 0.002 for the diamond detector and for the silicon diode, respectively. The delta values were found to be independent of particle type of two conventional beams (a 10 MV x-ray beam and a 21 MeV electron beam). So if delta is determined for a radiotherapy beam, it can be used to correct relative dosimetry for other conventional radiotherapy beams. Moreover the diamond detector shows a calibration factor which is independent of beam quality and particle type, so an empirical dosimetric formalism is proposed here to obtain the reference dosimetry. This formalism is based on a dose-to-water calibration factor and on an empirical coefficient, that takes into account the reading dependence on the dose per pulse.

Diamond↗

Radiochromic film dosimetry of a low energy proton beam.

In this work some dosimetric characteristics of MD-55-2 GafChromic films were studied in a low energy proton beam (21.5 MeV) directly in a water phantom. The nonlinearity of the optical density was quantified by a factor P(lin). A correction factor P(en), that accounts for optical density dependence on the energy, was empirically determined. The effects of detector thickness in depth dose measurements and of the film orientation with respect to beam direction were investigated. The results show that the MD-55-2 films provide dose measurements with the films positioned perpendicularly to the proton beam. A dosimetric formalizm is proposed to determine the dose to water at depth d, with films oriented perpendicularly to the beam axis. This formalism uses a calibration factor of the radiochromic film determined directly on the proton beam at a reference depth in water, and the P(lin) factor, that takes into account the nonlinearity of the calibration curve and the P(en) factor that, in turn takes into account the change of proton beam energy in water. The MD-55-2 films with their high spatial resolution and the quasiwater equivalent material are attractive, positioned perpendicularly along the beam axis, for the absolute dose determination of very small beam sizes and modulated proton beams.

Calibration↗

Alanine/EPR dosimetry in brachytherapy.

The paper reports the experimental procedure adopted to determine the absorbed dose rate in water per reference air kerma rate, D(Kr), (d, theta), along the transverse bisector axis of a 137Cs brachytherapy source. The dose rate measurements have been carried out at difference distances, d, from the source using alanine dosemeters in a water phantom. The reference air kerma rate, Kr, was determined adopting a 'direct procedure' that uses a spherical ionization chamber in air. The dose rate constant of the source examined was D(Kr) (1, pi/2) = 0.99 +/- 0.03 cGy h(-1) (microGy h(-1))(-1). The values of the radial dose function along the transverse axis, g(d), determined with an uncertainty of 3.4% (1sigma), were found to be in good agreement with the results reported in the literature. The uncertainty in dose rate value has been estimated as 2.8% (1sigma) for distances from the source up to 7 cm. Kr has been determined with 1.2% (1sigma) uncertainty. So D(r) (d, pi/2) values were determined with 3% (1sigma) uncertainty.

Alanine↗

Results of distal revascularization in elderly patients for critical ischemia of the lower limbs.

Thirty eight patients over 75 years of age were operated upon of 40 distal arterial revascularizations for critical ischaemia of the lower limbs. Arterial reconstruction was proposed to ambulatory, self sufficient patients, with a patent artery of the leg or the foot in continuity with pedal arch, at arteriography. The revascularized artery was the peroneal in 14 cases, the anterior tibial in 11, the posterior tibial in 9, the dorsalis pedis in 5, and the external plantar artery in 1 case. Postoperative mortality was 2.6%. No postoperative arterial occlusion occurred and no postoperative amputation needed to be performed. The mean follow-up of 37 patients surviving operation was 21 months (ext. 2-52 months). At 36 months interval, patients' survival was 43%, primary patency rate was 57%, and limb salvage rate was 76%, at life-table analysis. Distal revascularization enables a good number of elderly patients in critical ischaemia of the lower limb, to enjoy an active, independent life, with a viable limb.

Aged↗

Toward a general model for the description of multimedia clinical data.

The patient folder integrates information originating from heterogeneous sources. For this reason computerized tools for patient data management should exploit the advantages of multimediality and offer an integrated environment for data presentation, and image and biosignal visualization. Object-oriented modeling is the best approach for designing systems for multimedia patient folder management. We propose an object-oriented model, able to define the entities constituting the patient folder and their logical organization. This model has sufficient flexibility to adapt to the most varied clinical environments. It allows the physician to structure the information needed for his/her patient folder without employing a programming language.

Computer Simulation↗

Applications of the Italian protocol for the calibration of brachytherapy sources.

The Associazione Italianà di Fisica Biomedica (AIFB; Italian Association of Biomedical Physics) has adopted the Italian protocol for the calibration of brachytherapy sources. The AIFB protocol allows measurements of the reference air kerma rate, Kr, within 1.7% (1 sigma). To measure Kr the AIFB protocol has identified a direct and an indirect procedure. The direct procedure is based on the use of spherical or cylindrical ionization chambers as local reference dosimeters positioned along the transverse bisector axis of the source. Once the source is specified by a Kr value, this can be used to calibrate a field instrument, such as a well-type ionization chamber, for further source calibrations by means of an indirect procedure. This paper reports the results obtained by the Physics Laboratory of the Università Cattolica del S Cuore (PL-UCSC), in terms of Kr calibration of five types of source, 169Yb, 192Ir and 137Cs. The role of the Kr determination for a brachytherapy source has been underlined when a new source such as the 169Yb seed model X1267 has been proposed for clinical use. The Kr values for 137Cs spherical sources differed by 5% from the vendor's mean value. The five types of source calibrated in terms of Kr were used to obtain the calibration factor. NKrsource, of an HDR-1000 well-type ionization chamber.

Brachytherapy↗

[Comparison between measured and computed absorbed dose values in the tangential treatment of the breast].

The calculated absorbed dose values to the reference point of the breast tangential irradiation, obtained by 2-dimensional (2D) Treatment Planning Systems (TPS), were compared with the measured absorbed dose values obtained with a ionization chamber in an anthropomorphic phantom treated with two opposed photon beams of 60Co, 6 MV and 10 MV. This comparison was aimed at assessing the 2D algorithm dose overestimation due to the effect of missing tissue in the irradiated field. The ratio between the computed dose, Dc, and the measured dose, Dm, reached 1.08 for 60Co beams and 1.04 for X-ray beams of linacs. The Clarkson method gives an adequate correction factor for the calculated absorbed dose value in the reference point. The portal films of some patients were studied to estimate the correction factor for the treatment time or monitor units evaluated by TPS using tomographic breast central plane. The values of the correction factors reached 1.10 for 60Co photon beams and 1.04 for X-ray beams. The measurements were carried out with TLDs positioned in the central plane of the breast, covered by a special bolus, of a second anthropomorphic phantom. The dose homogeneity as well as the accuracy of the relative computed dose values in the breast phantom irradiated with 10 MV X-ray beams were assessed.

Absorption↗