MR-guided interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe.

The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy procedure was monitored with a surface coil in a 1.5 Tesla magnet using a gradient echo sequence. Follow-up examinations were performed 3 and 7 days after the freezing procedure using T1- and T2-weighted spin echo sequences. At 7 days the animals were sacrificed and the cryolesions were examined histologically. The cryoprobe enabled artifact-free MR imaging of the "iceball" formation during freezing of the rabbit liver. After 1 min of freezing, the iceball at the tip of the probe showed an average maximum diameter of 10.8 mm. No bleeding complications were observed during or after the freezing procedure. Histologic examination 7 days after cryotherapy confirmed that the liver lesions were the same size as had been predicted by the images of the acute iceball. This new, percutaneously inserted, MR-compatible, liquid-nitrogen cooled cryoprobe allows accurate, artifact-free MR imaging of interstitial cryotherapy.

Animals

Stability of different wiring techniques in segmental spinal instrumentation. An experimental study.

The pullout force of sublaminar and transspinous wires for segmental instrumentation which had been inserted into different segments of human cadaver spines were compared. Four different types of wiring were tested: single and double sublaminar wires, button-wires according to Drummond's technique and button-wires with the additional use of two crimps for each spinous process. A total of 50 tests were performed. In all attempts the bone proved to be the limiting factor. None of the 300 fixed wires failed. Typical types of fractures appeared with different wiring techniques. There was no statistically significant difference between the sublaminar wiring techniques tested. However, there were significant differences between sublaminar and transspinous wiring. The transspinous techniques achieved between 30% and 45% of the pull-out strength of sublaminar techniques. The forces decreased with increasing cranialisation. In all techniques the values in the upper segment (D5-D3) were almost half those of the lower segment (L5-L3). The differences of the transspinous techniques increased cranially, in favour of the technique with additional crimps. Thus, the crimps have the strongest effect on weak spinous processes. This study demonstrates that in non-dynamic testing, the stability of the bone and not the type of wiring is the limiting parameter in segmental spinal stabilisation. As the wires are inserted in different areas, the transspinous technique shows significantly lower tension forces in comparison with sublaminar wiring.

Biomechanical Phenomena

Anatomic and functional aspects of the kinetics of the shoulder joint capsule and the subacromial bursa.

This anatomic study was devoted to the kinetics of the shoulder joint and especially the subacromial region. Following dissection of the shoulder joint capsule and subacromial region of 80 unpreserved shoulder joints, the anatomic relationships of the subacromial space in the neutral position and in continuous abduction (30 degrees, 60 degrees and 90 degrees with fixed scapulae) were examined. These investigations were supplemented by histologic preparations. In the course of our examinations we discovered a gliding mechanism of the subacromial bursa. Moreover, we found a subcoracoid attachment of the shoulder joint capsule and a precoracoid ligamentous connection running between the short head of the biceps brachii m. and the coracoacromial ligament. We termed this the coracoid aponeurosis, which facilitates gliding behaviour of the shoulder joint capsule beneath the coracoid process. In view of this gliding mechanism of the subacromial bursa and the coracoid aponeurosis, discovered in the course of our investigations, we have to reassess the kinetics of the sub-acromial and subcoracoid space. Further, we should reconsider our operative technique in cases of the subacromial or subcoracoid impingement syndrome.

Bursa, Synovial

Femoral nerve lesion in total hip replacement: an experimental study.

A total of 20 hip joints of 10 non-fixed corpses were examined within 48 h of death to measure the pressure below the inguinal ligament simulating the surgical conditions during total hip arthroplasty. The purpose of this study was to assess the influence of various leg positions and insertion techniques of retractors during the surgical procedure for total hip replacement in order to detect supposed causes for indirect pressure injuries of the femoral nerve. The obtained results verified no increase of pressure in the inguinal canal which could explain an indirect injury of the femoral nerve. If the retractor is inserted correctly at the anterior acetabular rim, the pressure in the lacuna musculorum can even be reduced, and furthermore, the femoral nerve is protected by the iliopsoas muscle. Femoral nerve lesions which have been published so far can only be explained by an incorrect use of instruments or implants (e.g., screws, cement, acetabular cup) or an extreme postoperative leg length discrepancy.

Arthroplasty, Replacement, Hip

Anatomy and pathology of the aging spine.

The vertebral column is a complicated anatomical structure which is composed of the intervertebral discs and the vertebrae. Both components develop special degenerative changes and morphologic features during life. This paper first reviews the anatomical fundamentals and then describes the morphological features of the aging intervertebral disc and the subsequent osseous changes of the vertebral bodies and the zygapophyseal joints. The aging intervertebral disc is characterised by processes which are labeled as intervertebral chondrosis and intervertebral osteochondrosis. Often these processes are combined with typical dislocations of intervertebral disc tissue in an anterior or dorsolateral direction. The well known Schmorl's nodules must also be mentioned in this context. Furthermore calcification and ossification of the intervertebral disc tissue can take place. More severe processes lead to osseous changes of the vertebral bodies. In particular, an osteophytosis of the vertebral bodies can be established. These sturdy osteophytes are able to stiffen the vertebral column. Furthermore the arthrotic changes of the zygapophyseal joints are delineated in this paper. The special appearances of these changes are discussed according to the different and specialised regions of the vertebral column. The advanced degenerative changes of the zygapophyseal and uncovertebral joints of the cervical spine are of essential clinical interest because the compression of the vertebral artery or the narrowing of the intervertebral foramina by these processes may cause severe neurological symptoms. The arthrotic changes of the medial atlantoaxial joint, which lead to the crowned odontoid, and the pseudospondylolisthesis (so called M. Junghanns) of the lumbar spine must also be mentioned. It is the aim of this paper, not only to explain and review the degenerative changes, but to illustrate the anatomy and pathology of the aging spine on the basis of macerated osseous specimens in order to make radiological investigations and pictures more understandable and clear.

Aged

Mechanisms of accumulation of small particles of iron oxide in experimentally induced osteosarcomas of rats: a correlation of magnetic resonance imaging and histology. Preliminary results.

RATIONALE AND OBJECTIVES: This study was conducted to investigate the distribution and kinetics of small particles of iron oxide in osteosarcoma-like tumors. METHODS: Magnetic resonance (MR) imaging was performed in eight athymic nude rats with an experimentally induced osteosarcoma of the right hind leg immediately after intravenous injection of a superparamagnetic iron oxide preparation. Five animals received 150 mumol iron oxide/ kg and three received 50 mumol iron oxide/kg. The iron oxide preparation consisted of polythylenglycol-coated particles with a core diameter of 6 to 8 nm. The MR images were correlated with histologic slices of the tumors. RESULTS: The tumors accumulated iron oxide rapidly. A marked decrease in signal intensity, preferentially along the periphery of the tumor, was followed by a partial return of the signal intensity within the first minute. The maximum signal decrement throughout the entire tumor exceeded 41% and 21% with one dose each of 150 mumol iron/kg and 50 mumol iron/kg, respectively. The rate of return depended on the injected dose and tumor area, with the signal intensity approaching the initial value before the injection of iron oxide after 45 minutes. Histologic correlation only showed deposition of contrast medium in the proliferative areas of the tumors, mainly confined to the tumor margin. In addition to a predominantly extracellular deposition, intracellular storage could be detected. CONCLUSIONS: The findings help to advance the understanding of the distribution and kinetics of intravenous-injected small particles of iron oxide in osteosarcoma-like tumors. A first-pass accumulation of iron oxide could be documented by MR imaging in the periphery of osteosarcomas. Due to sieving of iron oxide particles by liver, spleen, and bone marrow, the signal intensity at 45 minutes after the injection of iron oxide returned to 89% (150 mumol iron oxide/kg) and 95% (50 mumol iron oxide/kg) of the preinjection intensity.

Animals

Anatomic study of femoral vein occlusion during simulated hip arthroplasty.

An anatomic study was undertaken to establish whether positioning of the leg and surgical approaches for total hip replacement (THR) cause changes in the femoral v. which may contribute to the development of deep vein thrombosis (DVT). The patency of 32 femoral vv. of 18 cadavers was inspected at different levels during simulated THR. Before and after removal of the femoral head through a transgluteal or posterior approach, a wide-angle endoscope was inserted into the femoral v. via the external iliac v. Blood flow was simulated by proximal irrigation with saline through the popliteal v. After removal of the femoral head distinct changes were observed in both approaches. In the transgluteal approach the changes were dependent on the degree of adduction and the body build of the cadaver. Initially, an oval form was seen in a constricted lumen with an increasingly oblique oval deformation and a final facet-like closure, usually at about 5 to 7.5 cm below the inguinal ligament. In total adduction this stenosis occurred regardless of build. Using a posterior approach, the necessary internal rotation caused a closure of the vein in 50% of cases. In combination with flexion and adduction there was stenosis in all cadavers regardless of body build. Our results indicate that the duration of the adducted position of the thigh during THR via a transgluteal approach should be minimised, as there is a reduction in blood flow with even minor degrees of adduction. In the posterior approach the stenosis occurs earlier, and is independent of the build of the cadaver.

Arthroplasty, Replacement, Hip

The sensory innervation of the hip joint--an anatomical study.

Typically obturator nerve blockade is used to relieve hip pain. It sometimes only has a minor effect in resolving symptoms. This clinical observation led us to examine comprehensively the sensory nerve innervation of formalin-fixed hip joint capsules. Following macroscopic preparation, the area of the hip joint capsule was inspected with the aid of an operating microscope. We discovered a separation between the anterior and posterior sensory innervation of the hip joint capsule. The anteromedial innervation was determined by the articular branches of the obturator n. Additionally, the anterior hip joint capsule was innervated by sensory articular branches from the femoral n. In the posterior part we found articular branches from the sciatic n., which in addition to the articular branches from the nerves to the quadratus femoris m., innervate the postero-medial section of the hip joint capsule. Moreover, articular branches of the superior gluteal n. were found, which innervate the posterolateral section of the hip joint capsule. This anatomical study demonstrates that the obturator n. block is insufficient for the treatment of hip pain. Further investigations will determine if these nn. can be reached percutaneously. Effective neural blockade of the hip joint must include the femoral n., the sciatic n. and the superior gluteal n.

Femoral Nerve

[Development and pathophysiology of abdominal wall defects].

Repair of abdominal wall hernias is the most frequently performed operation in surgery. Primary hernias arise at anatomical weak points; incisional hernias result from laparotomies. As the fascia heals slowly, the suture should be strong enough to withstand the intraabdominal pressure. Complications in wound healing may lead to a hernia, especially when absorbable sutures have been used. The rate of incisional hernias is technically influenced by the type of incision, the suture technique, and the suture material. To achieve adequate repair it is often necessary to change the principles of abdominal wall closure, for example by using alloplastic material. The meshes reinforce the architecture of the abdominal wall both by pure mechanical means and by induction of a stable scar formation (polypropylene, polyester).

Abdominal Muscles

Some remarks on, and a new case of the rare os intercuneiforme (Dwight).

A new case of the rare os intercuneiforme (Dwight) is presented and compared with the two cases reported by the anatomist first describing this bone. Taking a large series of anatomical investigations into account, the frequency of occurrence for this supernumerary tarsal bone can be given as 0.026%. Furthermore, it is supposed that the os intercuneiforme belongs rather to the medial than to the intermediate cuneiform.

Aged

The glenoid notch and its relation to the shape of the glenoid cavity of the scapula.

The prevalence of a notch in the anterior margin of the glenoid cavity of 236 scapulae (118 female, 118 male) was investigated. The notch was found in 129 scapulae (55%) and gave rise to a pear-shaped cavity. In 107 scapulae (45%) the notch was absent, the shape of the cavity being oval. No sex difference was found in the prevalence of the notch. If a distinct notch exists, the glenoid labrum is not attached to bone at the notch and is therefore liable to be sheared off (Bankart lesion).

Female

[A comparison between GE and SE sequences in MRT after the i.v. application of superparamagnetic iron particles in the assessment of experimentally induced soft-tissue osteosarcomas].

PURPOSE: An MRI study on experimentally induced osteosarcomas of the peripheral soft-tissues in nude rats was conducted, comparing SE and GE sequences after i.v. application of superparamagnetic iron oxides with regard to contrast and image quality. MATERIAL AND METHODS: 40 nude rats with an osteosarcoma in the right hind leg and 7 tumour-free animals were measured without, one and 48 hours after i.v.-injection of the contrast medium. 4 SE and 3 GE sequences with different parameters and slice orientation were applied. The contrast medium consisted of Fe3O4 particles with a core diameter of 6-8 nm and a coating material of polyethylene glycol (PEG). The laboratory animals were divided into 5 groups of 7-12 animals each. The rats of the first 4 groups were given a contrast-medium dosage of 100, 150, 200 and 250 mumol Fe/kg body weight, respectively. The animals of the fifth group were tumour-free and served as controls. RESULTS: The minimum dosage for detection of Fe3O4-containing PEG magnetites, one hour after application, was established at 100-150 mumol Fe/kg body weight. The higher the dosage of the contrast medium, the more signal alterations could be measured. The GE sequences were more sensitive than SE sequences. One GE sequence with the parameters TR 90 ms, TE 13 ms, FL 8 degrees turned out to be highly sensitive. CONCLUSION: Superparamagnetic iron oxides induce signal alterations in tumours of the peripheral soft tissue. GE sequences proved to be more sensitive than SE sequences.

Animals

Anatomo-experimental study for lace fixation of winged scapula in muscular dystrophy.

Winging of the scapula is one of the major features of the rare facio-scapulo-humeral muscular dystrophy. Several methods of retention and fixation of the scapulae have been published, but most have technical disadvantages or complications. A modified method of operative fixation of the scapula to the chest using three polyester laces is described with the results of cadaveric studies on the stability of this system. In order to determine the optimal region for the scapula fixation using polyester laces we performed pull-out tests on twenty cadaver scapulae. Four points of insertion in the inferior part of the scapula were tested. The lateral margin showed the best results with regard to the tensile strength and the morphology of the resulting fractures. The elongation of the laces was measured as well. Compared to scapulothoracic arthrodesis interscapulo-scapulocostal scapulopexy leads to greater preserved mobility between the scapula and the chest wall and conserves vital capacity.

Adolescent

MRI of degenerative bone marrow lesions in experimental osteoarthritis of canine knee joints.

OBJECTIVE: The objective of this study was to determine the value of MRI in the detection of degenerative bone marrow abnormalities in an animal osteoarthritis model. DESIGN: In 10 dogs with experimentally induced unilateral osteoarthritis of the knee, MRI was performed using two-dimensional spin-echo (2D-SE) and three-dimensional gradient-echo (3D-GE) imaging. Contrast enhanced T1-weighted 2D-SE sequences were also obtained after injection of gadolinium-DTPA. The results were compared with the gross and histopathologic findings and with radiography. RESULTS: Histopathologic specimens revealed 21 osteosclerotic lesions and 5 intraosseous cysts. On 2D-SE images, 24 of 26 lesions were detected, while 21 of 26 lesions were identified on 2D-GE sequences. Radiography, including conventional tomography, demonstrated 9 of 26 lesions. Regardless of the sequence weighting, all osteosclerotic lesions appeared hypointense on MRI. Signal loss in bone sclerosis resulted primarily from the reduction of intact fat marrow, the increased bone density being of secondary importance. Quantitative signal analysis allowed approximate estimation of the grade of sclerosis. On postcontrast images, sclerotic bone remained hypointense, although significant but non-specific enhancement relative to the normal fat marrow was observed. The extent of contrast enhancement did not correlate with the grade of osteosclerosis. All five cysts were readily diagnosed by MRI. Cysts displayed either central or marginal contrast enhancement within their cavities. CONCLUSIONS: MRI provides a sensitive method for the diagnosis of osteoarthritic bone abnormalities, allowing their differentiation from most non-degenerative subarticular lesions.

Animals

Bone cement penetration of the acetabulum in total hip replacement. An experimental study.

Cones of cement passing through, or below, the acetabulum may be seen after total hip replacement and are due either to iatrogenic perforation of the wall or to substantial bony defects. An experimental study was undertaken to establish which structures might be affected by these cones. In 20 cadaveric specimens, the acetabula were divided into 4 quadrants and, after the cement was set, the structures within the pelvis were dissected. In the antero-inferior quadrant the cement impinged on either the obturator nerve or vein, or the external iliac vein. Anterosuperiorly, these structures and the external iliac artery were impinged. In the posterior quadrants, the obturator muscle and nerve, and vessels, were affected, and inferiorly the external obturator muscle was also involved. The size of the cones depended on the bony depth of the acetabulum. Compared with screws, the cement can cause late complications through heat necrosis and continuous friction. The posterosuperior quadrant is the safest area to make holes for anchoring the cup.

Acetabulum

[MRT of experimental liver abscesses: a comparison of a new blood pool contrast medium with gadolinium-DTPA in animal experiments].

PURPOSE: In an experimental pyogenic liver abscess model, the signal intensities were compared intraindividually and interindividually after the application of a new blood pool contrast agent, 24-gadolinium-DTPA (diethylenetriamine-pentaacetic acid) cascade polymer, and after the application of gadopentetate dimeglumine. METHODS: In 20 rabbits with experimentally induced liver abscesses, the relative signal intensities of the liver, abscess centre, abscess wall and portal vein were assessed before and between 30 seconds and 60 minutes after injection of a 25 mumol/kg dose of gadolinium polymer and of 100 mumol/kg of gadolinium-DTPA, respectively. Measurements were performed at 1.5 Tesla, using a head coil and a Flash-2-D sequence. RESULTS: The interindividual comparison (unpaired T-test, p < 0.05) yielded significant differences of the relative signal intensities of the abscess centre (at any time point after contrast-media application), abscess wall (between 15 and 60 minutes after contrast media application), and portal vein (between 30 seconds and 7.5 minutes after contrast media application). The interindividual comparison showed a significantly higher abscess centre-liver contrast (between 30 seconds and 12.5 minutes after contrast media application) and a significantly higher abscess wall-centre contrast (between two and 7.5 minutes after contrast media application) after the application of gadolinium polymer compared with gadopentetate dimeglumine. CONCLUSION: In this animal model, the higher abscess centre-liver contrast after the application of gadolinium polymer was the basis for a better and prolonged visibility of the abscesses, as compared with images acquired after injection of gadopentetate dimeglumine.

Animals

Computed tomography of experimental liver abscesses using a new liposomal contrast agent.

RATIONALE AND OBJECTIVES: Evaluation of computed tomographic enhancement characteristics of a new liposomal contrast agent (liposomal iodixanol [LI]) in a pyogenic liver abscess model in 17 rabbits. METHODS: Eight to 14 days after abscess induction (Escherichia coli), density-time curves were calculated for regions of interest in liver, abscess wall and center, spleen, portal vein, abdominal aorta, inferior vena cava, and kidney. Images were obtained every minute between 1 and 10 minutes, every 5 minutes between 15 and 60 minutes, and 75 minutes after 200 mg/kg LI application (group A: 7 rabbits) and after 600 mg/kg iopentol application (group B: 10 rabbits), and 90, 105, and 120 minutes after LI. RESULTS: The abscess wall-liver contrast after LI lasted from 10 to more than 120 minutes with a maximum of 30 delta Hounsfield Units (HU) at 45 minutes. For iopentol, the abscess wall-liver contrast lasted from 2 to 7 minutes with a maximum of 8 delta HU at 5 minutes. The abscess wall-center contrast after LI lasted from 1 to more than 120 minutes with a maximum of 112 delta HU at 40 minutes. For iopentol, the abscess wall-center contrast lasted from 1 to 75 minutes with a maximum of 79 delta HU at 1 minute. The liver-portal vein contrast after LI lasted from 1 to more than 120 minutes with a maximum of 100 delta HU at 20 minutes. For iopentol, the liver-portal vein contrast lasted from 1 to 8 minutes with a maximum of 38 delta HU at 2 minutes. An abscess wall was detected in a higher percentage of the LI images (86% LI, 56% iopentol), and images in the LI group correlated better with histopathology. CONCLUSIONS: The diagnostic value of LI exceeds that of iopentol in terms of overall abscess contrast and duration of the diagnostic interval. The higher hepatic vessel contrast allows better abscess localization.

Animals