PubMed Health⌕ Search

Biomedical subjects

A R Moye

Publications and source records attributed to A R Moye.

3 recordsLinked to original sources

Investigation of the human oesophagus as a new monitoring site for blood oxygen saturation.

Pulse oximeter probes placed peripherally may fail to give accurate values of arterial blood oxygen saturation (SpO2) when peripheral perfusion is poor. Since central blood flow may be preferentially preserved, the oesophagus was suggested as an alternative monitoring site. A reflectance oesophageal photoplethysmographic (PPG) probe and a multiplexed data acquisition system, operating simultaneously at two wavelengths and incorporating an external three-lead electrocardiogram (ECG) reference channel, has been developed. It has been used to investigate the suitability of the oesophagus as a possible monitoring site for SpO2 in cases of compromised peripheral perfusion. Oesophageal PPG signals and standard ECG traces were obtained from 16 anaesthetized patients and displayed on a laptop computer. Measurable PPG signals with high signal-to-noise ratios at both infrared and red wavelengths were obtained from all five oesophageal depths investigated. The maximum PPG amplitude occurred at 25 cm from the upper incisors in the mid-oesophagus. The measured pulse transit times (PTTs) to the oesophagus were consistent with previous measurements at peripheral sites and had a minimum value of 67 +/- 30 ms at a depth of 30 cm. There was broad agreement between the calculated values of oesophageal SpO2 and those from a commercial finger pulse oximeter.

Adult↗

A system for investigating oesophageal photoplethysmographic signals in anaesthetised patients.

The monitoring of arterial blood oxygen saturation in patients with compromised peripheral perfusion is often difficult, because conventional non-invasive techniques such as pulse oximetry (SpO2) can fail. Poor peripheral circulation commonly occurs after major surgery including cardiopulmonary bypass. The difficulties in these clinical situations might be overcome if the sensor were to monitor a better perfused central part of the body such as the oesophagus. A new oesophageal photoplethysmographic (PPG) probe and an isolated processing system have been developed to investigate the pulsatile signals of anaesthetised adult patients undergoing routine surgery. Measurements were made in the middle third of the oesophagus, 25 cm to 30 cm from the upper incisors. The AC PPG signals are sampled by a data acquisition system connected to a laptop computer. The signals recorded correspond to infrared and red AC PPGs from the middle third oesophagus and the finger. Preliminary results from 20 patients show that good quality AC PPG signals can be measured in the human oesophagus. The ratio of the oesophageal to finger AC PPG amplitudes was calculated for the infrared and red wavelengths for each patient. The mean (+/- standard deviation) of this ratio was 2.9 +/- 2.1 (n = 19) for the infrared wavelength and 3.1 +/- 2.4 (n = 16) for the red wavelength. The red and infrared wavelengths used are appropriate for pulse oximetry and this investigation indicates that the mid-oesophagus may be a suitable site for the reliable monitoring of SpO2 in patients with poor peripheral perfusion.

Adult↗