PubMed Health⌕ Search

Biomedical subjects

A R Sandy

Publications and source records attributed to A R Sandy.

3 recordsLinked to original sources

Crossover from stretched to compressed exponential relaxations in a polymer-based sponge phase.

X-ray photon correlation spectroscopy was used to characterize the wave vector- and temperature-dependent dynamics of spontaneous thermal fluctuations in a sponge (L3) phase that occurs in a blend of a symmetric poly(styrene-ethylene/butylene-styrene) triblock copolymer with a polystyrene homopolymer. Measurements of the intermediate scattering function reveal a crossover from stretched- to compressed-exponential relaxations as the temperature is lowered from 180 to 120 degrees C.

Journal Article↗

Absence of scaling for the intermediate scattering function of a hard-sphere suspension: static and dynamic x-ray scattering from concentrated polystyrene latex spheres.

X-ray photon correlation spectroscopy and small-angle scattering measurements are presented of the dynamics and structure of concentrated suspensions of charge-stabilized polystyrene latex spheres dispersed in glycerol, for volume fractions from 3% to 52%. The static structures of the suspensions show essentially hard-sphere behavior, and the short-time dynamics shows good agreement with predictions for the wave-vector-dependent collective diffusion coefficient. However, the intermediate scattering function is found to violate a scaling behavior found previously for a sterically stabilized hard-sphere suspension.

Journal Article↗

Small-angle X-ray scattering using coherent undulator radiation at the ESRF.

A simple approach for producing a high-coherent-flux X-ray beam for small-angle-scattering studies used at the Troika beamline of the European Synchrotron Radiation Facility is reported. For such small-angle studies it is permissible to reduce the longitudinal coherence .length of the beam, thus increasing the energy bandpass and intensity of the beam, because there is only a small optical path-length difference. By using mirrors and filters to cut unwanted energies from the undulator harmonic structure, a high-flux beam of >10(9) photons s(-1) through a 5 micron-diameter pinhole at 8.2 keV with a bandpass of 1.3% can be produced. The coherent properties of this beam have been measured by analyzing a static speckle pattern from an aerogel sample imaged by a directly illuminated CCD camera. The speckle size and contrast are compared with the expected values based on a statistical analysis of the intensity distribution of speckle patterns obtained using partially coherent conditions. The expected widths of the spatial autocorrelation are found, but there is an apparent incoherent fraction of the beam which reduces the measured contrast. The method presented is to be used as a tool to optimize conditions for diffraction experiments using coherent X-rays.

Journal Article↗