T(2) selectivity: comparison between different kinds of RF pulses.

Techniques allowing characterization of specific T(2) species are used to perform MR imaging of structures whose signal intensity is poor on conventional methodologies. T(2)-selective pulses can be used to discriminate signals from tissues with different T(2) values. In case of soliton pulses, the magnetization from all the T(2) species is inverted, with the exception of specific T(2) structures which have both the longitudinal and the transverse magnetization nulled on resonance. Solitons have the drawback of being very long even if the selected T(2) value is in the order of tens of milliseconds. The aim of this paper is to examine whether it is possible to use pulses shorter then solitons keeping their T(2) selectivity, that is keeping null longitudinal magnetization, while accepting some residual transverse magnetization for structures with the selected T(2). Different kinds of inversion pulses were generated, all to select the same T(2) species. Pulses performance was analyzed by studying the dependence of the residual transverse magnetization on resonance from the length of the pulse. An exponential relationship between transverse magnetization and pulse length was found, which was not dependent on the pulse type.

Journal Article↗

Relaxation effects on transverse magnetization using RF pulses long compared to T(2).

The transverse relaxation effects which occur during the application of optimized slice-selective Shinnar-Le Roux pulses are studied. The behavior of both longitudinal and transverse magnetization is examined, focusing the attention on changes which affect the absorption and dispersion components. Besides the reduction in amplitude, the absorption component was found to be unaffected by transverse relaxation times, whereas the dispersion component was strongly distorted. A comparison between the distortion components from pulses having same length but different bandwidths is given.

Magnetic Resonance Spectroscopy↗

Optimized Shinnar-Le Roux RF 180 degrees pulses in fast spin-echo measurements.

Optimized Shinnar-Le Roux (SLR) pulses have very good slice profiles with no sidelobes and very small out-of-slice ripples with nearly constant amplitude. In multislice fast spin-echo (FSE) imaging, a better slice definition changes the stimulated echo (STE) and magnetization transfer (MT) contribution on contrast and signal. We investigated the effects of STE and MT on signal and contrast enhancement when optimized 180 degrees SLR pulses are used in multislice FSE measurements. From the results obtained in both phantom and volunteer studies, it can be inferred that using optimized 180 degrees SLR pulses with band-widths larger than that of the conventional 180 degrees sinc-pulse allows significant signal improvement and contrast enhancement.

Algorithms↗

A Generalized Estimate of the SLR B Polynomial Ripples for RF Pulse Generation.

The nonlinearity of the parameter relations for the Shinnar-Le Roux RF pulse design algorithm has induced to performa classification based on the features of the slice profile dueto the RF pulse. In the present paper a generalization ofthe relation between the ripple amplitudes of the SLR B polynomial and those of the slice profile is given. It allows generation of RF pulses with better slice profiles and slightly reduced energy, avoiding any a priori classification. The effect of our estimation has been shown by generating several pulses by generalized estimation of B polynomial ripples. In addition, their behavior has been compared to that of analogous pulses generated by means of the classification just mentioned. Copyright 1998 Academic Press.

Journal Article↗