PubMed Health⌕ Search

Biomedical subjects

A Rienäcker

Publications and source records attributed to A Rienäcker.

5 recordsLinked to original sources

Comparing regularized and non-regularized nonlinear dipole fit methods: a study in a simulated sulcus structure.

The inverse problem arising from EEG and MEG is largely underdetermined. One strategy to alleviate this problem is the restriction to a limited number of point-like sources, the focal source model. Although the singular value decomposition of the spatio-temporal data gives an estimate of the minimal number of dipoles contributing to the measurement, the exact number is unknown in advance and noise complicates the reconstruction. Classical non-regularized nonlinear dipole fit algorithms do not give an estimate for the correct number because they are not stable with regard to an overestimation of this parameter. Too many sources may only describe noise but can still attain a large magnitude during the inverse procedure and may be indiscernible from the true sources. This paper describes a nonlinear dipole fit reconstruction algorithm with a new regularization approach for the embedded linear problem, automatically controlled by the noise in the data and the condition of the occuring least square problems. The algorithm is stable with regard to source components which "nearly" lie in the kernel of the projection or lead field operator and it thus gives an estimate of the unknown number parameter. EEG simulation studies in a simulated sulcus structure are carried out for an instantaneous dipole model and spatial resolution in the sulcus and stability of the new method are compared with a classical reconstruction algorithm without regularization.

Brain Mapping↗

Properties of advanced headmodelling and source reconstruction for the localization of epileptiform activity.

During the last decade multiple work has been done to determine the sources of epileptiform activity by means of dipole source localization based on recordings of the magnetoencephalogram (MEG) or the electroencephalogram (EEG). The actual available advanced volume conductor models and the multiple source reconstruction by regularization may give new impulse to EEG based source analyses in epilepsy patients. This study demonstrates the principal properties of these techniques. We applied two different EEG source reconstruction techniques within different volume conductor models to localize induced spike activity in a selected patient suffering from medically intractable temporal lobe epilepsy: 1) single moving dipole solution in a 3-shell spherical model versus individual head models (boundary-element-model, BEM, and finite-element-model, FEM); 2) a regularization technique for current density reconstructions using both BEM and FEM. When compared to findings of invasive recordings no adequate source locations were derived from the moving dipole solution in both the 3-shell head model and BEM. In contrast, a high congruence of source reconstruction and invasive determination of the focus was obtained using the regularization techniques in both BEM and FEM, indicating the high spatial accuracy of this technique in individual head models.

Adult↗

The influence of skull-conductivity misspecification on inverse source localization in realistically shaped finite element head models.

The electric conductivities of different tissues are important parameters of the head model and their precise knowledge appears to be a prerequisite for the localization of electric sources within the brain. To estimate the error in source localization due to errors in assumed conductivity values, parameter variations on skull conductivities are examined. The skull conductivity was varied in a wide range and, in a second part of this paper, the effect of a nonhomogeneous skull conductivity was examined. An error in conductivity of lower than 20% appears to be acceptable for fine finite element head models with average discretization errors down to 3 mm. Nonhomogeneous skull conductivities, e.g., sutures, yield important mislocalizations especially in the vincinty of electrodes and should be modeled.

Brain↗

Inverse localization of electric dipole current sources in finite element models of the human head.

The paper describes finite element related procedures for inverse localization of multiple sources in realistically shaped head models. Dipole sources are modeled by placing proper monopole sources on neighboring nodes. Lead field operators are established for dipole sources. Two different strategies for the solution of inverse problems, namely combinatorial optimization techniques and regularization methods are discussed and applied to visually evoked potentials, for which exemplary results are shown. Most of the procedures described are fully automatic and require only proper input preparation. The overall work for the example presented (from EEG recording to visual inspection of the results) can be performed in roughly a week, most of which is waiting time for the computation of the lead field matrix or inverse calculations on a standard and affordable engineering workstation.

Cerebral Cortex↗

Origin of P16 median nerve SEP component identified by dipole source analysis--subthalamic or within the thalamo-cortical radiation?

Following median nerve stimulation, several monophasic peaks were recorded at the scalp in the 15-18 ms time range. Source analysis, using three different methods, modelled a source near the centre of the head with an orientation towards the activated hemisphere and a peak activity at 16 ms post stimulus. Magnetic recordings detected no signal in this time range, which confirmed a subcortical location of the source. From dipole localization it was not possible to assign the exact origin of the P16 source to either the subthalamic level or the thalamo-cortical radiation, because of the limited spatial resolution at the centre of the spherical head model. An estimate of the conduction velocity of the medial lemniscus pointed towards a subthalamic origin. The P16 source was preserved in two patients with a lesion of the thalamo-cortical radiation and the ventral thalamus. Further evidence for a subthalamic location of P16 was derived from the physical mechanisms generating far-field potentials.

Adult↗