Reactive astrocytes in myelin-deficient rat optic nerve reveal an altered distribution of orthogonal arrays of particles (OAP).

Reactive astrocytes are a common feature of various pathological conditions within the CNS. Morphological changes of reactive astrocytes include an altered nucleus-cytoplasm relationship, nuclear indentations, an increased amount of intermediate filaments, and an immunologically immature phenotype. Additionally, the number of orthogonal arrays of particles (OAP) was found to be increased within parenchymal membranes of reactive astrocytes. This observation prompted us to investigate the distribution of astroglial OAP in the amyelinated CNS of the myelin-deficient (md) rat in which reactive astrocytes prevail. In the present freeze-fracture study, astroglial OAP were determined within endfoot and nonendfoot (parenchymal) membranes in the developing optic nerve of md rats and normal littermates at the age of 12, 23, 40, and 64 days postnatally (dpn). The endfoot OAP density in md astrocytes remained constant during the entire period of investigation. In myelinated littermates, OAP densities continuously increased up to adult values. In contrast, the parenchymal OAP density in md astrocytes increased during the entire period of investigation. In normal littermates, OAP densities remained constant during the first 40 dpn and thereafter increased rapidly. These observations suggest that the absence of myelinogenesis in the md mutant may be a stimulus for parenchymal membranes of reactive astrocytes to insert OAP or to assemble OAP subunits into complete arrays.

Aging

Aimed movements to visual targets in hemiplegic and normal children: is the "good" hand of children with infantile hemiplegia also normal?

The accuracy, reaction and movement time of pointing movements to visual targets were examined in children aged 3-13 yr with infantile hemiplegia and compared to those of comparably aged normal children. Hemiplegic children pointed with the "good" hand (i.e. ipsilateral to the lesion). Half the normal children used the preferred hand, half the non-preferred hand. Movements were made with unrestricted/restricted visual feedback, when movement distance was short/medium/long, and when number of target alternatives were 2/4/8. Normal children using the preferred hand were more accurate but reacted more slowly than children using the non-preferred hand. The performance of most of the hemiplegic children with bilateral and/or unilateral lesions was impaired; degree of accuracy was related to the extent of the brain lesion; and reaction time was related to the level of intelligence. It was concluded that unilateral lesions in children can result in bilateral visuomotor impairment.

Adolescent

Multichannel strain gauge telemetry for orthopaedic implants.

In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hip prostheses, the telemetry can also be used for other implants. Its size makes feasible instrumentation of devices with only slight mechanical modifications. In addition to the description of our own measuring system, the paper gives a survey on the problems of telemetrized implants, on methods for measuring spatial loads, and on the investigations of other authors. Future publications will present in vivo measurements with this telemetry, among others on hip endoprostheses.

Equipment Design

A nonlinear finite element analysis of interface conditions in porous coated hip endoprostheses.

We used a geometrically simplified finite element model to investigate load transfer between a porous coated hip endoprosthesis and a femur. Assuming both rigidly bonded and nonlinear interfaces, we analyzed fully and partially coated stems that had coatings of different elastic moduli. Our results indicate that maximum values for relative motion in the interface between bone and implant occur for implants with the same elastic modulus as compact bone. By comparison, interface motion is reduced by about half for Co-Cr-Mo alloy stems. We also showed that the elastic modulus of the porous coating had only a small influence on bone stresses.

Biomechanical Phenomena

Effects of stem design and material properties on stresses in hip endoprostheses.

With the aid of a three-dimensional finite element stress analysis a parameteric study of the essential aspects of the femoral component of hip endoprostheses was carried out. Various designs were investigated; these included the prosthetic stem length, the existence or non-existence of the prosthetic collar and the elastic modulus of stem and cement. Variations in the stem length have only minor effects on the stress distribution for a stem length greater than 100 mm, but the elastic modulus of the prosthetic stem has a considerable influence on the stresses. A high elastic modulus of the stem increases the stresses in the stem but it decreases stresses in the cement. The cement stresses increase with an increase in the modulus of elasticity of the cement.

Bone Cements

[A technique for reproducible roentgenograms of the intercondylar sulcus for the study of the femoropatellar (author's transl)].

Roentgenographic documentation of certain features of FP-joint geometry and orientation may serve as guideline in deciding on the form of treatment for chondromalacia or recurrent patellar dislocation. Reproducible conditions for taking roentgen films are equally important for this purpose as well as for quantitative measurements and possible statistical work. A new positioning device for the patient's legs has been designed utilizing a parallellogram frame. The roentgenographic technique for skyline views at 30 degree, 60 degree and 90 degree inclination of the central beam relative to the femoral axis is described. The advantages over previous techniques are the ease of handling the positioning frame, the need for only vertical and horizontal adjustment of the roentgen tube, independence of the type of tube or table, reproducibility of cassette and patient positioning.

Adult

[Walking with canes and forearm-crutches (author's transl)].

Partial weight bearing is frequently prescribed but cannot be controlled adequately. In a previous paper the change of forces at the hip joint as effected by a one sided cane was determined by instrumentation of the cane and a mechanical analysis of gait on a walkway. In the present study we looked at the conditions for control of partial weightbearing when two forearm crutches are used. Instrumented crutches and a forceplate were used. In walking with two forearm crutches the total of the ground reaction forces and the force pattern differ from those in free walking. The total of two crutch forces plus the force at the leg with partial weightbearing exceeds that caused by body weight alone. This is due to mass accelerations in a changed gait pattern. When the maximal leg force is reduced from 100% body weight to zero, the additional dynamic forces exceed those caused by body weight alone by 4%-19%. Only 2% of the additional dynamic forces act on the controlateral crutch while the rest is transmitted through the ipsilateral crutch. The crutch force pattern on the ipsilateral side depends more on individual gait characteristics than does that on the controlateral side. Load reduction is more pronounced in the late stages of the stand phase than in the early ones.

Adult

[Critical observations and the loads on femoral head replacement and the femoral bone calculated for a support in 3 points (author's transl)].

In their attempts at calculation of forces acting on a femoral head implant and the forces transmitted to the bone, some authors have assumed support of the implant in a few distinct points. It can be shown, however, that forces thus calculated very much depend on the direction and point of action of the supporting forces assumed arbitrarrily. The suggestion to implant a prosthesis in a "valgus" position cannot be justified by results obtained by the method in question. The change in the resultant force at the hip joint due to positioning in "varus" or "valgus" has not been taken into account by previous authors. In the valgus position of the femoral head prosthesis the resultant hip force is up to 33% greater than that in a "varus" position.

Biomechanical Phenomena