PubMed Health⌕ Search

Biomedical subjects

A Roorda

Publications and source records attributed to A Roorda.

11 recordsLinked to original sources

Packing arrangement of the three cone classes in primate retina.

We describe a detailed analysis of the spatial arrangement of L, M and S cones in the living eyes of two humans and one monkey. We analyze the cone mosaics near 1 degrees eccentricity using statistical methods that characterize the arrangement of each type of cone in the mosaic of photoreceptors. In all eyes, the M and L cones are arranged randomly. This gives rise to patches containing cones of a single type. In human, but not in monkey, the arrangement of S-cones cannot be distinguished from random.

Animals↗

Functional consequences of the relative numbers of L and M cones.

Direct imaging of the retina by adaptive optics allows assessment of the relative number of long-wavelength-sensitive (L) and middle-wavelength-sensitive (M) cones in living human eyes. We examine the functional consequences of variation in the relative numbers of L and M cones (L/M cone ratio) for two observers whose ratios were measured by direct imaging. The L/M cone ratio for the two observers varied considerably, taking on values of 1.15 and 3.79. Two sets of functional data were collected: spectral sensitivity measured with the flicker electroretinogram (ERG) and the wavelength of unique yellow. A genetic analysis was used to determine L and M cone spectra appropriate for each observer. Rayleigh matches confirmed the use of these spectra. We determined the relative strength of L and M cone contributions to ERG spectral sensitivity by fitting the data with a weighted sum of L and M cone spectra. The relative strengths so determined (1.06 and 3.38) were close to the cone ratios established by direct imaging. Thus variation in L/M cone ratio is preserved at the sites tapped by the flicker ERG. The wavelength of unique yellow varied only slightly between the two observers (576.8 and 574.7 nm). This small variation indicates that neural factors play an important role in stabilizing unique yellow against variation in the L/M cone ratio.

Adult↗

The arrangement of the three cone classes in the living human eye.

Human colour vision depends on three classes of receptor, the short- (S), medium- (M), and long- (L) wavelength-sensitive cones. These cone classes are interleaved in a single mosaic so that, at each point in the retina, only a single class of cone samples the retinal image. As a consequence, observers with normal trichromatic colour vision are necessarily colour blind on a local spatial scale. The limits this places on vision depend on the relative numbers and arrangement of cones. Although the topography of human S cones is known, the human L- and M-cone submosaics have resisted analysis. Adaptive optics, a technique used to overcome blur in ground-based telescopes, can also overcome blur in the eye, allowing the sharpest images ever taken of the living retina. Here we combine adaptive optics and retinal densitometry to obtain what are, to our knowledge, the first images of the arrangement of S, M and L cones in the living human eye. The proportion of L to M cones is strikingly different in two male subjects, each of whom has normal colour vision. The mosaics of both subjects have large patches in which either M or L cones are missing. This arrangement reduces the eye's ability to recover colour variations of high spatial frequency in the environment but may improve the recovery of luminance variations of high spatial frequency.

Cell Count↗

An infrared eccentric photo-optometer.

An objective infrared optometer has been designed, based on the optical principles of eccentric photorefraction. A CCD camera with an eccentric infrared light source images the subject's pupil through a Badal optometer. The slope of the light distribution across the pupil is continuously recorded. Accommodative state is measured by moving the camera behind the Badal lens until the slope is zero. This position corresponds to the case where the camera is conjugate with the retina of the observer. In this Badal optometer, the irradiance of light at the pupil plane, the sensitivity of the photorefractor, and the focal setting of the camera lens remain constant for all positions of the camera from the eye. The repeatability of a single measure of refractive state in a cyclopleged eye was less than 0.05 D. Static accommodative responses taken from 3 subjects in both closed and open loop conditions provided expected stimulus/response measures. The instrument can also be adapted to measure dynamic accommodation.

Accommodation, Ocular↗

Slope-based eccentric photorefraction: theoretical analysis of different light source configurations and effects of ocular aberrations.

A geometrical-optical technique is used to predict the changes in the slope of the eccentric-photorefraction intensity profiles as a function of refractive state. We investigate how the intensity profiles vary with refractive state for different light source configurations and monochromatic aberrations in the eye. The best possible light source configuration extends from zero eccentricity (to increase sensitivity and reduce the dead zone) to a high eccentricity (to increase the working range). An advantage of using the extended light source is that the intensity profile of the eccentric-photorefraction reflex is more linear for extended sources than for point light sources. It is also shown that the change in slope with refractive state is dependent on pupil size. Furthermore, when asymmetric aberrations are present, the change in intensity profile slope with refractive state is dependent on the circumferential position of the light source, but this dependence can be resolved by averaging slope values obtained by using two sources placed on opposite sides of the pupil. The importance of this study to existing eccentric-photorefractor designs is discussed, and recommendations for improved eccentric photorefractors are suggested.

Color Vision Defects↗

Geometrical technique to determine the influence of monochromatic aberrations on retinoscopy.

A geometrical-optical analysis is developed to predict the reflex observed in retinoscopy. The analysis can be expanded to explain the reflex for an eye with aberrations. The succession of reflexes across the pupil for each position of the retinoscope is represented in a contour plot. The plots demonstrate that retinoscopy can be considered a measure of the transverse ray aberration of the eye. For an eye with simple defocus this causes the typical with and against motions observed with hyperopic and myopic refractive errors. For an eye with aberrations we predict more-complex retinoscopic reflexes. This theory is confirmed by actual measurements on a human eye with known aberrations.

Color Perception↗

Retinoscopic reflexes: theoretical basis and effects of monochromatic aberrations.

BACKGROUND: Current literature describing retinoscopy does not provide a full description of the pupil reflexes observed in retinoscopy or of the effects of monochromatic aberrations. The intent of the study was to develop a geometrical model of retinoscopy that provides a more complete analysis. The model can take specific aberrations and predict the succession of reflexes observed in retinoscopy for an eye with these aberrations. METHODS: Theoretical predictions were compared with observations using a hand-held streak retinoscope. CCD-based retinoscopy was performed on subjects with known aberrations. RESULTS: Reflexes observed in retinoscopy can be computed by modeling a light source whose eccentricity from the retinoscope sight-hole is varying in position. Results from study calculations show that the succession of reflexes observed in retinoscopy can be thought of as a measure of the transverse aberration of the eye. Both qualitative and quantitative measures showed agreement between theoretical and experimental results. Transverse aberration of the eye can be observed and measured using retinoscopy. CONCLUSIONS: Monochromatic aberrations have significant and predictable effects on retinoscopy. The best way for a retinoscopist to avoid such aberrations and provide a proper refraction is to neutralize the reflex across the largest visual zone possible and ignore the reflex motion at the edges of the pupil.

Humans↗

Effect of monochromatic aberrations on photorefractive patterns.

Photorefractive methods have become popular in the measurement of refractive and accommodative states of infants and children owing to their photographic nature and rapid speed of measurement. As in the case of any method that measures the refractive state of the human eye, monochromatic aberrations will reduce the accuracy of the measurement. Monochromatic aberrations cannot be as easily predicted or controlled as chromatic aberrations during the measurement, and accordingly they will introduce measurement errors. This study defines the error or uncertainty by extending the existing paraxial optical analyses of coaxial and eccentric photorefraction. This new optical analysis predicts that, for the amounts of spherical aberration (SA) reported for the human eye, there will be a significant degree of measurement uncertainty introduced for all photorefractive methods. The dioptric amount of this uncertainty may exceed the maximum amount of SA present in the eye. The calculated effects on photorefractive measurement of a real eye with a mixture of spherical aberration and coma are shown to be significant. The ability, developed here, to predict photorefractive patterns corresponding to different amounts and types of monochromatic aberration may in the future lead to an extension of photorefractive methods to the dual measurement of refractive states and aberrations of individual eyes.

Accommodation, Ocular↗

Geometrical theory to predict eccentric photorefraction intensity profiles in the human eye.

In eccentric photorefraction, light returning from the retina of the eye is photographed by a camera focused on the eye's pupil. We use a geometrical model of eccentric photorefraction to generate intensity profiles across the pupil image. The intensity profiles for three different monochromatic aberration functions induced in a single eye are predicted and show good agreement with the measured eccentric photorefraction intensity profiles. A directional reflection from the retina is incorporated into the calculation. Intensity profiles for symmetric and asymmetric aberrations are generated and measured. The latter profile shows a dependency on the source position and the meridian. The magnitude of the effect of thresholding on measured pattern extents is predicted. Monochromatic aberrations in human eyes will cause deviations in the eccentric photorefraction measurements from traditional crescents caused by defocus and may cause misdiagnoses of ametropia or anisometropia. Our results suggest that measuring refraction along the vertical meridian is preferred for screening studies with the eccentric photorefractor.

Computer Simulation↗

Adaptive optics ophthalmoscopy.

Retinal images in the human eye are normally degraded because we are forced to use the optical system of the human eye--which is fraught with aberrations--as the objective lens. The recent application of adaptive optics technology to measure and compensate for these aberrations has produced retinal images in human eyes with unprecedented resolution. The adaptive optics ophthalmoscope is used to take pictures of photoreceptors and capillaries and to study spectral and angular tuning properties of individual photoreceptors. Application of adaptive optics technology for ophthalmoscopy promises continued progress toward understanding the basic properties of the living human retina and also for clinical applications.

Humans↗