PubMed HealthSearch

Biomedical subjects

A S Robertson

Publications and source records attributed to A S Robertson.

At least 19 recordsLinked to original sources

Bladder augmentation and replacement. Urodynamic and clinical review of 25 patients.

Bladder augmentation has a role in the management of patients with neuropathic bladder dysfunction and in urinary undiversion. Several reports attest to its clinical value, but there have been few detailed urodynamic studies of its effects. We have carried out a prospective review over a 4-year period of 25 patients undergoing bladder augmentation or substitution assessed by conventional and ambulatory urodynamic studies. All patients had a detubularised reservoir made of ileum in 6, and of the ileocaecal segment in the remainder. Six patients also had an artificial sphincter fitted and 2 underwent colposuspension. There was no mortality. After operation, bladder capacity increased from 122 +/- 91 ml to 659 +/- 431 ml and there were significant decreases in the pressure rise during filling and increases in bladder compliance. Hyper-reflexia was present in 74% before operation and 23% after operation. Regular phasic activity was observed in 77% of patients at the end of filling after operation, probably due to bowel activity despite detubularisation. Four patients described urge incontinence associated with this activity. After operation, one man had persistent major stress incontinence. He has since undergone insertion of an artificial urinary sphincter (AUS) and is now completely dry. Of the remainder, 10 patients had minor, infrequent defects in continence, 9 patients with leakage when the bladder was full and 4 with occasional leakage at night. With the exception of the patient with major stress incontinence, all but one felt the operation had been worthwhile--40% reporting complete success and 52% excellent improvement. Reconstruction of the neuropathic lower urinary tract is a major surgical procedure, but the final clinical outcome is very satisfactory.

Adolescent

Response to corticosteroids in chronic airflow obstruction: relationship to emphysema and airways collapse.

We have studied the relationship between emphysema and airways collapse, and response to corticosteroids in patients with chronic airflow obstruction. One hundred and seven patients completed a placebo-controlled trial comparing 2 wks treatment with oral prednisolone 40 mg.day-1 to inhaled beclomethasone dipropionate 500 micrograms t.d.s. Response to corticosteroids was defined on the basis of changes in forced expiratory volume in one second (FEV1), and/or forced vital capacity (FVC), and/or mean peak expiratory flow (PEF) after treatment. Patients were categorized as those with physiologically defined emphysema (carbon monoxide transfer coefficient (KCO) less than 70% predicted and total lung capacity greater than 120% predicted), and those with pressure dependent airways collapse on the flow-volume loop (ratio of inspiratory to expiratory flow at 50% vital capacity [I:E50] greater than 10). The response to placebo showed a significant order effect, probably due to a carry-over effect of active treatment of at least 3 wks. Hence, the efficacy of active treatment over placebo in the subgroups defined was assessed by analysis of data generated from the first treatment phase of the trial. The presence or absence of physiologically defined emphysema did not affect the response to oral prednisolone. Inhaled beclomethasone dipropionate, however, was less effective in the emphysema group. Pressure dependent airways collapse did not affect the response to either prednisolone or beclomethasone. However, when data from all three treatment phases were analysed there was no significant difference in the response to either drug in any of the subgroups defined.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Inhalation

A familial interstitial deletion of the long arm of chromosome 21.

A mother and daughter with an interstitial deletion of the chromosome segment 21q11 to 21q21.3 have similar minor dysmorphism and mild mental retardation. These two patients are compared to others in the literature with deletion of the same region of chromosome 21. Molecular analysis of DNA from our patients localizes the DNA segments D21S1, D21S11, D21S8, and D21S22 within the deleted region.

Abnormalities, Multiple

Corticosteroid trials in non-asthmatic chronic airflow obstruction: a comparison of oral prednisolone and inhaled beclomethasone dipropionate.

One hundred and twenty seven adults considered on clinical grounds to have non-asthmatic chronic airflow obstruction entered a randomised, double blind, placebo controlled, crossover trial comparing the physiological response to inhaled beclomethasone dipropionate 500 micrograms thrice daily with oral prednisolone 40 mg a day, both given for two weeks. One hundred and seven patients completed the study. Response was assessed as change in FEV1 and FVC measured on the last treatment day, and as change in mean peak expiratory flow (PEF) over the final seven days of treatment from home PEF recordings performed five times daily. A full response to treatment was defined as an increase in FEV or FVC, or an increase in mean daily PEF over the final seven days of treatment, of at least 20% from baseline values. An improvement in one measurement of at least 15%, or of 10% in any two measurements, was defined as a partial treatment response. Response to placebo showed a significant order effect, suggesting a carry over effect of active treatment of at least three weeks. Response to active treatment was therefore related to initial baseline values, and compared with placebo by considering responses in the first treatment phase only. A full response to oral prednisolone (16/38) was significantly more common than to placebo (3/35). The number of full responses to inhaled beclomethasone (8/34) did not differ significantly from the number responding to oral prednisolone or placebo in the first treatment phase, though full and partial responses to inhaled beclomethasone (12/34) were significantly more common than those to placebo (4/35). When all three treatment phases were considered 44/107 patients showed a full response to one or both forms of corticosteroid treatment, a response to prednisolone (39) occurring more frequently than to inhaled beclomethasone (26). Only 21 of the 44 responders showed a response to both forms of treatment. Inhaled beclomethasone dipropionate 500 micrograms thrice daily was inferior to oral prednisolone 40 mg per day, but better than placebo, in producing improvement in physiological measurements in patients thought to have nonasthmatic chronic airflow obstruction. It was, however, an effective alternative in over half of those showing a response to prednisolone.

Administration, Inhalation

Time course of response to oral and inhaled corticosteroids in non-asthmatic chronic airflow obstruction.

One hundred and twenty one patients considered on clinical grounds to have non-asthmatic chronic airflow obstruction completed a double blind, crossover trial comparing oral prednisolone 40 mg per day with inhaled beclomethasone dipropionate 500 micrograms thrice daily, each given for 14 days, with a 14 day washout period between treatments. The time course of response was analysed for the 57 occasions where there was a significant increase in mean daily peak expiratory flow (PEF) over the treatment period. Mean daily PEF was still rising at day 14 on 12 occasions. After withdrawal of treatment mean daily PEF remained above pretreatments levels for more than two weeks in half the responses analysed. The peak response occurred earlier with inhaled beclomethasone (median 9.5 (range 3-14) days) than with oral prednisolone (median 12 (range 1-14) days), though both treatments produced a response that was sustained for a similar period. The results suggest that a trial of treatment with corticosteroids in this group of patients should last more than 14 days, and that in a study with a crossover design the washout period should be longer than two weeks.

Administration, Inhalation

Building sickness, are symptoms related to the office lighting?

Office lighting has been suggested as one of the possible factors in producing 'building sickness'. Health questionnaires were completed by 106 out of 109 (97%) workers in six randomly sampled multi-occupied offices in each of two buildings, one air-conditioned and one naturally ventilated. There was a significantly higher prevalence of work-related headache and work-related lethargy in the air-conditioned building than in the naturally ventilated one. There was also less daylight in the air-conditioned building and lower mean luminance and illuminance of the work positions despite there being more lights on (p less than 0.01). The workers had a greater dislike of fluorescent lighting (p less than 0.01) and overall found the lighting to be less comfortable (p less than 0.01) and glare readings were higher. The workers perceived their control of lighting as poorer (p less than 0.001) and consequently there was less agreement about it (p less than 0.001). Those with work-related headache found the lighting less comfortable (p = 0.059) and perceived more glare (p less than 0.05). This study suggests the need to maximize the use of natural light from untinted windows, to reduce the impingement of fluorescent tubes on the line of sight and to return the control of levels of lighting to each individual worker.

Environment Design

An interstitial deletion of the long arm of chromosome 13.

A case of an interstitial deletion of chromosome 13, identified as 46,XY,del(13)(q22q31), is reported in a child with psychomotor retardation, prominent low-set ears, epicanthus, hypertelorism, broad nasal bridge, hypoplastic fifth fingers and abnormal dermatoglyphics. This patient is compared to others in the literature with a similar deletion.

Child, Preschool

Highlights from the Canada youth and AIDS study.

The identification of Acquired Immunodeficiency Syndrome (AIDS) in 1981, and the subsequent isolation of the human immunodeficiency virus (HIV) in 1983, signaled the beginning of worldwide concern over the potential impact of the disease. As the global incidence of AIDS and HIV infection increased, Canadians expressed growing apprehension about the epidemic's affect on themselves. Because adolescents potentially are at risk for HIV infection, a special need existed to determine how Canadian youth were responding to the AIDS epidemic. During the summer of 1987, the Federal Centre for AIDS, in conjunction with the National Health Research and Development Program and the Canadian Public Health Association, commissioned a nationwide study. A national sample of more than 38,000 youth in grades 7, 9, 11, and the first year of college and university were surveyed about their knowledge, attitudes, and behavior concerning AIDS and other sexually transmitted diseases (STDs). Also included in the total sample were youth who had recently dropped out of school and those who lived on the streets of large cities. In this article, the authors summarize findings from the study and offer conclusions and recommendations for action.

Acquired Immunodeficiency Syndrome

Occupational asthma due to soft corrosive soldering fluxes containing zinc chloride and ammonium chloride.

Two cases of occupational asthma due to soft corrosive soldering fluxes used in metal jointing are described in which the diagnosis was based on work related deterioration in daily peak expiratory flow rate and positive responses in bronchial provocation tests. Both fluxes contained ammonium chloride and zinc chloride. Occupational asthma provoked by these agents has not previously been reported.

Adolescent

Occupational asthma due to oil mists.

Twenty five patients who were exposed to oil mists at their place of work were investigated for possible work related asthma. Serial peak expiratory flow recordings showed 13 to have definite work related asthma, seven equivocal work related asthma, and three asthma unrelated to work; two had normal recordings. Subjects with work related asthma often produced different patterns of peak flow response during the working week; patterns also varied between patients. Six of these patients had bronchial tests with oil from their place of work. Three had asthma induced by exposure to unused (clean) soluble oil and one reacted to used but not to clean oil. The challenge tests in the remaining two gave inconclusive results. It is concluded that occupational asthma due to oil mists is common, the peak flow response is heterogeneous, and the provoking agent within the oil may vary from worker to worker.

Adult

A study of serum thiocyanate concentrations in office workers as a means of validating smoking histories and assessing passive exposure to cigarette smoke.

Patients in clinical practice often falsely report their smoking status. To see if this was so in occupational surveys we have validated smoking histories (using a serum thiocyanate assay) in 206 randomly sampled office workers who completed a smoking questionnaire administered by a doctor. Past and present cigarette consumption was determined with an assessment of exposure to passive cigarette smoke at home and at work in the non-smokers. Serum thiocyanate concentrations were measured by the ferric nitrate method. All smoking groups showed mean thiocyanate concentrations greater than non-smokers except those smoking five or fewer cigarettes a day. There was a significant increase in plasma thiocyanate with increasing smoking (p less than 0.01). Non-smokers with and without exposure to passive smoke could not be separated by thiocyanate concentration. In our hands serum thiocyanate concentrations identified moderate and heavy smokers but could not distinguish between non-smokers, light smokers, and passive smokers. Fourteen non-smokers had serum thiocyanate concentrations higher than 70 mumol/l which were still raised on a repeat sample. On a further questionnaire two admitted to smoking. To help confirm non-smoking status, expired carbon monoxide levels were also checked in this group. One person had a level of 22 ppm and subsequently admitted to smoking. In the others the levels were less than or equal to 10 ppm. Using a combination of serum thiocyanate assay and exhaled breath carbon monoxide levels, non-smoking was confirmed in 98% of those stating that they were non-smokers. In non-smokers exposure to passive cigarette smoke was much more likely to occur at work than at home.

Environmental Exposure

Extrinsic allergic alveolitis caused by a cold water humidifier.

Three workers developed classical extrinsic allergic alveolitis while working in a printing works that had a contaminated cold water humidifier. All had nodular shadows on their chest radiographs, reduced gas transfer measurements, and lung biopsy specimens that showed an alveolitis with giant cells and cholesterol clefts. In two subjects bronchoalveolar lavage was performed and the lavage fluid contained more than 70% lymphocytes in each case. Bronchial provocation tests with the humidifier antigen in these two workers reproduced their symptoms. Unlike previously reported cases, where exposure was to humidifiers working at generally higher temperatures, challenge with thermophilic actinomycetes in our two patients produced no reaction. Tests for precipitins to the humidifier antigen gave strongly positive reactions in the three workers but no single organism isolated from the humidifier produced a significantly positive reaction.

Air Conditioning

A double-blind comparison of oral prednisolone 40 mg/day with inhaled beclomethasone dipropionate 1500 ug/day in patients with adult onset chronic obstructive airways disease.

A double-blind cross-over trial was carried out on 83 sequential out-patients presenting with adult onset chronic airflow obstruction who were not clearly asthmatic. The study consisted of three treatment phases each lasting two weeks with a two week interval between each phase. The treatment phases were prednisolone 40 mg daily, beclomethasone dipropionate 500 ug three times a day and placebo, administered in a random order. FEV1 and FVC were measured at the end of each of the treatment phases and peak expiratory flow rate five times a day throughout. Over the study period 25 (30%) patients responded with an improvement of greater than or equal to 20% in at least one of the parameters measured as compared with the best of either baseline or placebo measurements. A further eight patients were classified as partial responders with an improvement of greater than 15% in any single parameter or greater than 10% in any two parameters. A similar number responded to beclomethasone [15] as responded to prednisolone [16]. Only six patients, however, responded fully to both forms of steroid therapy. A number of patients responded to one form of steroid treatment only which was also comparable between the two groups (prednisolone 10, beclomethasone 9). For full and partial responders mean improvement in FEV1, FVC and PEFR was greater during the prednisolone phase than during the beclomethasone phase, however, the difference did not achieve statistical significance.

Aged

Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems.

A cross sectional survey investigating "building sickness" was carried out in two buildings with similar populations of office workers but differing ventilation systems, one being fully air conditioned with humidification and the other naturally ventilated. The prevalence of symptoms related to work was assessed by a questionnaire administered by a doctor. A stratified, randomly selected sample of workers was seen (84% response). Building sickness includes several distinct syndromes related to work, most of which were significantly more common in the air conditioned building than the naturally ventilated building--namely, rhinitis (28% v 5%), nasal blockage and dry throat (35% v 9%), lethargy (36% v 13%), and headache (31% v 15%). The prevalence of work related asthma and humidifier fever was low and did not differ significantly between the two buildings. An environmental assessment of the offices was performed to attempt to identify possible factors responsible for the differences in the prevalence of disease. Globe temperature, dry bulb temperature, relative humidity, moisture content, air velocity, positive and negative ions, and carbon monoxide, ozone, and formaldehyde concentrations were all measured. None of these factors differed between the buildings, suggesting that building sickness is caused by other factors.

Air Conditioning