Multicenter audiometric results with the Vibrant Soundbridge, a semi-implantable hearing device for sensorineural hearing impairment.

The Vibrant Soundbridge, a semi-implantable hearing device for subjects with moderate to severe sensorineural hearing impairment was introduced commercially. First audiologic results are presented on 63 patients from 10 European implant centers. Hearing loss was at 0.5, 1, 2, and 4 kHz varying between 43 and 81 dB HL. The patients used the analogue audio processor, type 302. Measured sound-field gain was compared with NAL-R target values. For most patients an acceptable agreement was found. There was a subgroup of patients, however, with relatively low gain. The results suggest that this was related to the suboptimal positioning and fixation of the transducer to the incus.

Audiometry, Speech↗

Clinical experience with the Vibrant Soundbridge implant device.

OBJECTIVE: To evaluate the full degree and range of benefits provided by the Vibrant Soundbridge (VSB; Symphonix Devices, Inc., San Jose, CA, U.S.A.) and analyze pre-and postoperative results of audiologic tests. STUDY DESIGN: Single-subject study with each subject serving as his or her own control. SETTING: Multicenter clinical study conducted at 10 centers in Europe. PATIENTS: 47 patients who met the selection criteria for participation in the study. INTERVENTIONS: Implantation of the VSB direct-drive middle ear hearing device. MAIN OUTCOME MEASURES: Average change in unaided thresholds with the patient wearing headphones at each frequency pre-and postsurgery was measured. A mean threshold change less than 5 dB across all frequencies was considered clinically nonsignificant. RESULTS: 47 patients had successful surgery for implantation and fitting with the VSB device. CONCLUSION: The VSB is a new middle ear implant device that can be used safely in the treatment of patients with moderate to severe sensorineural hearing loss.

Acoustic Stimulation↗

Speech-perception performance in prelingually deafened French children using the nucleus multichannel cochlear implant.

PURPOSE: The speech-perception abilities of 36 French children, whose onset of deafness occurred before 2 years of age, was longitudinally examined after they received a Nucleus multichannel cochlear implant. METHODS: Speech perception was assessed in four areas: phoneme detection, closed-set word and sentence recognition; and modified open-set recognition. RESULTS: All children achieved phoneme detection by 3 months after implantation. Closed-set word and sentence recognition appeared initially less accurate in children with congenital deafness than in the prelingually deafened children; however, these differences disappeared by 18 months after implantation. Some modified open-set recognition was evident by 12 months after implantation and continued to improve 3 years after implantation. CONCLUSIONS: Data demonstrate significant improvements in speech perception with implant experience: 15 (60%) of 25 of the children identified sentences in closed sets, 22 (88%) of 25 identified words in closed sets after 12 months' experience, and 13 (81%) of 16 demonstrated open-set recognition after 24 months of implant use.