PubMed Health⌕ Search

Biomedical subjects

A Sabir

Publications and source records attributed to A Sabir.

5 recordsLinked to original sources

Formulation and process optimization to eliminate picking from market image tablets.

A tablet formulation when compressed using market image tooling may cause picking of powder. A D-optimal statistical experiment was designed to optimize the direct compression formulation and the process to alleviate picking of powder. The effects of levels of magnesium stearate, colloidal silicon dioxide (CSD), and lubrication time on picking were investigated using original compression tooling. These optimization results provided a small robust manufacturing region, hence a change in the cut angles of embossed letters and numbers from 70 degrees to 90 degrees in the modified compression tooling was evaluated. A statistical analysis of the data identified a robust manufacturing region that included formulations containing magnesium stearate 1-1.25% w/w, CSD 0.1-0.3% w/w, with a lubrication time of 5-10 min when compressed using modified compression tooling. The results indicate a significant reduction in picking by increasing the cut angles of embossed letters and numbers in the modified compression tooling. By evaluating interactions between various variables, we demonstrate a concentration dependent effect of CSD on the lubrication efficiency of magnesium stearate and compactability of microcrystalline cellulose containing formulation. In addition, the lubrication efficiency of magnesium stearate is maintained by blending CSD with powder blend prior to lubrication with magnesium stearate.

Drug Compounding↗

Parathyroid hormone acutely increases polyphosphoinositides of the rabbit kidney cortex by a cycloheximide-sensitive process.

Parathyroid hormone(PTH) rapidly increases the concentrations of diphosphoinositide and triphosphoinositide in rabbit kidney cortex. Cycloheximide pretreatment abolishes these effects of PTH. These findings are similar to those reported for adrenocorticotropin and cyclic AMP action in the adrenal cortex, and suggest a common mechanism. Cycloheximide-sensitive effects of PTH, e.g., phosphaturia, may require polyphosphoinositides and/or other phospholipids.

Animals↗

The vacuum geometry effect on neutron transmission and spatial resolution of neutron transmission.

Frequently, shields used against radiation contain some vacuum channels. We have therefore considered an infinite slab with a fixed thickness (thickness 20 lambda with lambda the mean free path of the neutron in the slab) and an infinite plane source of neutrons which arrived on the left side of the slab; transmitted neutrons through the slab to its right side are detected by finite detectors having windows equal to 2 lambda. This slab contains a vacuum channel. This channel has many legs with several horizontal parts. We used the Monte Carlo method for sampling the neutron history in the slab with a spatial biasing technique in order to accelerate the calculation convergence (Levitt, L. B. (1968) Nuclear Science and Engineering 31, 500-504; Jehouani, A., Ghassoun, J. and Aboubker, A. (1994) In Proceedings of 6th International Symposium on Radiation Physics, Rabat, Morocco). We studied the effects of the angle position and the number of horizontal parts of the channel on the neutron transmission. We have studied the effect of the vacuum channel opening (Artigas, R. and Hungerford, H. E. (1969) Nuclear Science and Engineering 36, 295-303) on the neutron transmission; for several values of this opening we have calculated the neutron transmission probability for each detector position. This study allowed us to determine the optimal conditions of vacuum geometries to improve protection against neutrons. In the second part we considered a shield which consists of a slab and a two-legged vacuum channel with two horizontal parts. The spatial distribution of neutrons transmitted through the protection screen was determined. This distribution shows two peaks. The study was made for different distances between the two horizontal parts. We have determined the smallest distance between the two horizontal parts for which the two peaks can be resolved.

Monte Carlo Method↗

The albedo effect on neutron transmission probability.

The aim of this study is to evaluate the albedo effect on the neutron transmission probability through slab shields. For this reason we have considered an infinite homogeneous slab having a fixed thickness equal to 20 lambda (lambda is the mean free path of the neutron in the slab). This slab is characterized by the factor Ps (scattering probability) and contains a vacuum channel which is formed by two horizontal parts and an inclined one (David, M. C. (1962) Duc and Voids in shields. In Reactor Handbook, Vol. III, Part B, p. 166). The thickness of the vacuum channel is taken equal to 2 lambda. An infinite plane source of neutrons is placed on the first of the slab (left face) and detectors, having windows equal to 2 lambda, are placed on the second face of the slab (right face). Neutron histories are sampled by the Monte Carlo method (Booth, T. E. and Hendricks, J. S. (1994) Nuclear Technology 5) using exponential biasing in order to increase the Monte Carlo calculation efficiency (Levitt, L. B. (1968) Nuclear Science and Engineering 31, 500-504; Jehouani, A., Ghassoun, J. and Abouker, A. (1994) In Proceedings of the 6th International Symposium on Radiation Physics, Rabat, Morocco) and we have applied the statistical weight method which supposes that the neutron is born at the source with a unit statistical weight and after each collision this weight is corrected. For different values of the scattering probability and for different slopes of the inclined part of the channel we have calculated the neutron transmission probability for different positions of the detectors versus the albedo at the vacuum channel-medium interface. Some analytical representations are also presented for these transmission probabilities.

Monte Carlo Method↗

The neutron channeling phenomenon.

Shields, used for protection against radiation, are often pierced with vacuum channels for passing cables and other instruments for measurements. The neutron transmission through these shields is an unavoidable phenomenon. In this work we study and discuss the effect of channels on neutron transmission through shields. We consider an infinite homogeneous slab, with a fixed thickness (20 lambda, with lambda the mean free path of the neutron in the slab), which contains a vacuum channel. This slab is irradiated with an infinite source of neutrons on the left side and on the other side (right side) many detectors with windows equal to 2 lambda are placed in order to evaluate the neutron transmission probabilities (Khanouchi, A., Aboubekr, A., Ghassoun, J. and Jehouani, A. (1994) Rencontre Nationale des Jeunes Chercheurs en Physique. Casa Blanca Maroc; Khanouchi, A., Sabir, A., Ghassoun, J. and Jehouani, A. (1995) Premier Congré International des Intéractions Rayonnements Matière. Eljadida Maroc). The neutron history within the slab is simulated by the Monte Carlo method (Booth, T. E. and Hendricks, J. S. (1994) Nuclear Technology 5) and using the exponential biasing technique in order to improve the Monte Carlo calculation (Levitt, L. B. (1968) Nuclear Science and Engineering 31, 500-504; Jehouani, A., Ghassoun, J. and Aboubker, A. (1994) In Proceedings of the 6th International Symposium on Radiation Physics, Rabat, Morocco). Then different geometries of the vacuum channel have been studied. For each geometry we have determined the detector response and calculated the neutron transmission probability for different detector positions. This neutron transmission probability presents a peak for the detectors placed in front of the vacuum channel. This study allowed us to clearly identify the neutron channeling phenomenon. One application of our study is to detect vacuum defects in materials.

Neutrons↗