Experimental validation of a rapid Monte Carlo based micro-CT simulator.

We describe a newly developed, accelerated Monte Carlo simulator of a small animal micro-CT scanner. Transmission measurements using aluminium slabs are employed to estimate the spectrum of the x-ray source. The simulator incorporating this spectrum is validated with micro-CT scans of physical water phantoms of various diameters, some containing stainless steel and Teflon rods. Good agreement is found between simulated and real data: normalized error of simulated projections, as compared to the real ones, is typically smaller than 0.05. Also the reconstructions obtained from simulated and real data are found to be similar. Thereafter, effects of scatter are studied using a voxelized software phantom representing a rat body. It is shown that the scatter fraction can reach tens of per cents in specific areas of the body and therefore scatter can significantly affect quantitative accuracy in small animal CT imaging.

Algorithms↗

Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data.

In this study we present the analysis of in vivo micro-CT scans using a new method based on image registration that accurately evaluates longitudinal micro-CT studies. We tested if detailed changes in the bone architecture could be detected and tracked in individual animals. A prototype in vivo micro-CT scanner (Skyscan 1076) was developed in which tibiae of rats that are lying on a bed under gas anaesthesia were scanned. For this study, three female Wistar rats were used: a sham-operated rat, an ovariectomised (OVX) rat and one rat that served as a reproducibility control. The reproducibility control rat was scanned twice in 1 day. The other animals were scanned at week 0, just before surgery, at week 4 and at week 14 after surgery. Architectural changes over time were detected by overlaying two data sets made at different time points using an algorithm that uses mutual information for optimal registration. The scans were segmented into binary data sets using a local thresholding algorithm. The reproducibility test showed small errors of less than 3% in bone volume measurements and errors less than 0.5% in measurements of trabecular thickness. The sham-operated rat showed no changes in total bone volume, though thinning and eventual loss of some small trabeculae could be detected, which could be related to the age of the animal. The OVX rat lost much trabecular bone volume, especially in the metaphysis (60% at week 4, 75% at week 14). The remaining trabeculae slowly increased in thickness. Following the different scans in time showed the forming of new trabecular structures. Additionally, small longitudinal growth at the growth plate could be detected after the first 4 weeks. Further, the OVX rat showed extensive modelling at the proximal endosteal lateral cortex. We have shown a new method that can detect and track changes in the local bone architecture and individual trabeculae in time, in an individual living animal. This method enables longitudinal in vivo micro-CT studies and has the potential to greatly contribute to experimental rat or mouse studies on pharmacological intervention and transgenic models.

Animals↗

3D in-vivo X-ray microtomography of living snails.

In this paper we report the first in-vivo scanning of living snails by desktop X-ray microtomograph with a resolution up to 10 m. Consecutive cross-sections were acquired without destroying the specimen. Subsequently, 3D images were reconstructed. The results clearly demonstrate the possibilities of in-vivo scanning. Processes of growth and regeneration of living snails were visualized over a period of time.

Animals↗

Desktop X-ray microscopy and microtomography.

Recent developments in X-ray microtomography have made it possible to miniaturize a CT scanner into a versatile and cost-effective desktop system that fits into any laboratory environment. The possibilities of the technique are demonstrated for a range of applications. It is also shown how an existing scanning electron microscope with an X-ray detector can, with a specially developed attachment, be transformed into an X-ray microscope and microtomograph.

Journal Article↗

Desktop X-ray microscopy and microtomography.

Recent developments in X-ray microtomography have made it possible to miniaturize a CT scanner into a versatile and cost-effective desktop system that fits into any laboratory environment. The possibilities of the technique are demonstrated for a range of applications. It is also shown how an existing scanning electron microscope with an X-ray detector can, with a specially developed attachment, be transformed into an X-ray microscope and microtomograph.

Animals↗