PubMed Health⌕ Search

Biomedical subjects

A Sezai

Publications and source records attributed to A Sezai.

36 records · Page 2Linked to original sources

Effects of concomitant usage of milrinone and catecholamine for weaning from cardiopulmonary bypass.

To estimate the effectiveness of concomitant usage of milrinone and catecholamine for weaning from cardiopulmonary bypass (CPB), a clinical study was made, in elective coronary artery bypass grafting (CABG) cases. 24 consecutive patients underwent elective CABG in our institute. In all cases, moderate hypothermia and cardioplegic(St. Thomas solution) cardiac arrest were performed. In 12 cases, continuous intravenous 0.25 microgram/kg/min of milrinone, 3 micrograms/kg/min of dobutamine (DOB) and dopamine (DOA) as the initial doses, were used concomitantly as inotropic agents (Group-I). The same initial doses of catecholamine (DOB and DOA) as the Group-I were administered in another 12 patients (Group-II). When the pump flow of CPB decreased to a half, these drugs were administered in both groups. Hemodynamic data were measured before CPB, just after operation, 3, 6, 12, 24, 48, and 72 hours after operation. There were no significant differences in aortic and pulmonary artery pressure between both groups. However, cardiac index (CI) of the Group-I demonstrated significantly (p < 0.01) higher values than that of Group-II until 24 hours after surgery. Systemic vascular resistance index (SVRI) of the Group-I demonstrated significantly (p < 0.01) lower value than that of Group-II from 3 to 12 hours after operation. There were no significant differences in oxygen delivery (DO2) and oxygen consumption (VO2) between both groups. These results suggested that concomitant usage of milrinone and low dose catecholamine increased CI and decreased SVRI, and made weaning from CPB very easy, demonstrating excellent hemodynamics. This high potential phosphodiesterase inhibitor may be suitable for not only weaning from CPB but also post-cardiotomy cardiogenic shock.

Cardiopulmonary Bypass↗

[Microcirculation of kidney and skin during left ventricular assisted circulation--comparative studies of pulsatile and nonpulsatile assists].

We examined microcirculation of the kidney and skin over a six-hour period in an acute myocardial infarction model in pigs. The outflow cannula was placed in the ascending aorta, the inflow cannula was placed the in left atrium, and a pump was connected to each (pulsatile group, Zeon Medical pneumatic pump; nonpulsatile group, Nikkiso HPM-15). Items examined included the regional blood flow of the cortex and medulla in the kidney and skin, renal and carotid arterial flow, arterial ketone body ratio (AKBR), lactate/pyruvic acid (L/P), BUN, creatinine, and beta 2-microglobulin. After the experimental study, the major organs were removed and a pathological study was performed. The mean aortic pressure after the assist could be maintained at about 100 mmHg. There were no significant differences between the two groups in mean aortic pressure and total cardiac output. Under assisted circulation, the pulse pressure was maintained at about 15 mmHg in the nonpulsatile group and about 40 mmHg in the pulsatile group. After the assist, there were no significant differences in the carotid arterial blood flow between the two groups. However, there were significant differences between the two groups in the renal arterial, renal cortical, and regional skin blood flows. In the laboratory data, there were significant differences between the two groups in AKBR, L/P, and beta 2-microglobulin. Pathological findings on the kidney in the nonpulsatile group showed expansion of the proximal tubes, retention of red blood cells, and expansion of blood capillaries within the glomerulus. On the other hand, the pulsatile group showed almost normal formation. In the lungs, the nonpulsatile group showed edematous change in the air cells and the pulsatile group showed almost normal formation. The results of the previous and current study indicated that the pulsatile assist produced superior circulation in the kidney and peripheral organs and superior cellular metabolism in the early treatment of acute left cardiac failure. On the other hand, nonpulsatile assisted circulation was found to be ineffective in maintaining the circulation in the body, and to be potentially capable of causing irreversible damage of major organs if continuous for more than three hours. The results also indicated that pulsatility was necessary to maintain normal circulation in the peripheral organs and cellular metabolism in the early treatment of acute left cardiac failure.

Animals↗

Clinical experiences of percutaneous cardiopulmonary support: its effectiveness and limit.

In recent years, several types of centrifugal pumps have been widely used as the main pumps for cardiopulmonary bypass (CPB) and postcardiotomy cardiac support. From April 1990 to March 1997, a percutaneous cardiopulmonary support (PCPS) system was used in 20 patients with an average age of 58 years (13 males and 7 females). They comprised 11 ischemic, 6 valvular, 2 aortic, and 1 congenital heart disease patients. Our PCPS system consists of a centrifugal pump (BioMedicus BP-80), an oxygenator, and a reservoir. The entire blood contacting surface, including that of the thin wall cannulas, is coated by heparin bonded materials. As a result of this new technology, this system can be used for the long term without systemic heparinization. No major critical thrombi were revealed inside the pumps or circuits. Of the 20 patients, 7 (35%) (Group 1) could be weaned from PCPS, and the remaining 13 (Group 2) could not. In Group 1 although 2 patients suffered from renal failure and pneumonia, respectively, both were discharged from our hospital. The long-term survival rate was 35%. In Group 2 cerebral vascular damage was recognized in 3 patients, renal failure in 4, multiple system organ failure in 4, bleeding in 2, arrhythmia in 1, and leg ischemia in 2. Pulse pressure was significantly elevated due to the recovery of the native heart in Group 1, 2 days after support. However, in Group 2, it did not elevate, and the left ventricular ejection fraction was less than 30%, associated with high left atrial pressure. In conclusion, this heparin coated PCPS system was very simple and easy to control. It demonstrated long-term biocompatibility and was very effective in recovering deteriorated cardiac function. Quicker application of this system can play an important role in preventing severe complications and obtaining better clinical results. If long-term support is necessary, a ventricular assist device (VAD), which is more powerful, durable, and biocompatible, has to be applied instead of PCPS.

Acute Kidney Injury↗

Left atrial myxoma with an atrial septal defect: a case report and review of the literature.

We report a case of a 49 year-old Japanese woman with a left atrial myxoma complicated by an atrial septal defect diagnosed intraoperatively, which was classified as in secundum defect and was 28x110 mm in diameter. The tumor, which was attached by a pedicle to the posterior wall of the left atrium near the posterior commissure of the mitral valve, was removed together with a small portion of the left atrial wall. The postoperative course was uneventful. The pathologic findings were consistent with the diagnosis of myxoma. Since the defect was functionally canceled by the myxoma, the diagnosis of an atrial septal defect was not confirmed preoperatively even by color Doppler echocardiography and cardiac catheterization. Tumor embolization is one of the critical complications of myxoma. Fortunately, she didn't suffer from either systemic or pulmonary emboli. During surgery of myxoma with atrial septal defect, careful manipulation is needed, especially at caval cannulation so as not to damage the tumor directly. In the cases with atrial septal defect or patent foramen ovale, myxomas are generally situated on the interatrial septum. However, in this case the tumor was located on the posterior wall of the left atrium.

Cardiac Catheterization↗

Macroscopic aspects of cloth-covered Starr-Edwards prostheses at reoperation: what the precursory valve teaches us.

BACKGROUND AND AIMS OF THE STUDY: Cloth-covered Starr-Edwards ball valves were the first choice in prosthetic substitution at the authors' institution between June 1968 and March 1977. This study investigated, retrospectively, macroscopic aspects of the prostheses at reoperation. METHODS: Among 59 survivors who underwent isolated aortic or mitral valve replacement, 12 required reoperation for valve dysfunction (five aortic valve replacements, seven mitral valve replacements). Reoperation was necessitated by valvular endocarditis, paravalvular leak, hemolysis, thromboembolism, orifice stenosis attributable to pannus, and inappropriate sizing related to growth and thrombus. The mean time to reoperation was 11.7 +/- 6.2 years after initial surgery (range: 2 years 4 months to 21 years 8 months). RESULTS: Marked cloth wear was observed in all aortic prostheses, but only slight wear in mitral valves. Pannus formation was observed around the orifice in both aortic and mitral prostheses, but strut cloth was not extensively covered by autologous tissue. In mitral valves, strut cloth was only slightly worn and less loose than that of the aortic valve. These changes notably affected prosthetic valve function, the most significant problem in mitral prostheses being thrombus (four of seven valves). CONCLUSIONS: Pannus formation and thrombus caused by the reaction of the patient's tissues remain major problems in the use of artificial valves, and require further work for their improvement.

Adolescent↗

Post-operative effects of olprinone after coronary artery bypass grafting.

The aim of this study was to test the effects of olprinone after coronary artery bypass grafting (CABG). In order to prevent hypotension caused by olprinone, low doses of catecolamines were used concomitantly. Total 22 elective CABG cases were evaluated. In all cases, moderate hypothermia and cardioplegic cardiac arrest were performed. In 10 cases, continuous intravenous 0.1 microg/kg/min of olprinone, 3 microg/kg/min of dobutamine (DOB) and dopamine (DOA) as the initial doses, were used concomitantly (Group I). As a control, the same initial doses of catecolamine (DOB and DOA) of Group I were administered in another 12 patients (Group II). When the pump flow of cardiopulmonary bypass (CPB) was decreased to half, these drugs were administered in both groups. Hemodynamics were recorded before CPB, just after the operation and 3, 6, 12, 24, 48, and 72 hours after the operation. Three hours after the operation, both mean aortic pressure (AoP) and pulmonary artery pressures (PAP) of Group I demonstrated significantly lower values than those of Group II. Cardiac index (CI) of Group I showed significantly higher values than that of Group II until 6 hours after surgery. The systemic vascular resistance index (SVRI) of Group I indicated a significantly lower value than that of Group II until 24 hours after the operation. Pulmonary capillary wedge pressure (PCWP) of Group I demonstrated a significantly lower value than that of Group II. There were no significant differences in urine output, oxygen delivery (DO2) and oxygen consumption (VO2) between both groups. Olprinone increased CI and decreased SVRI, and it showed easy weaning from CPB, demonstrating excellent hemodynamics after CABG. These results suggested that this new phosphodiesterase inhibitor may be effective for not only weaning from CPB but also post-cardiotomy cardiogenic shock.

Aged↗

Congenital coronary artery fistula treated surgically in the right atrium and the atrial septum.

Various surgical techniques have been employed according to the type of the coronary fistula. In this case, preoperative examinations by aortography and MRI revealed a coronary artery fistula which originated from a site just proximal of the RCA, ran through the interatrial septum and drained into the posterior wall of right atrium. The ratio of pulmonary to systemic blood flow (Qp/Qs) was 1. 95. During surgery, we were not able to ligate or divide the fistula on the cardiac surface because the fistulous vessel originated from the posterior aspect of the proximal RCA. After establishing a cardiopulmonary bypass, the opening of the fistula in the right atrium was closed with an autologous pericardium patch, the surface of the interatrial septum was incised and the fistula was identified. The conduit was then divided and closed in the atrial septum. The postoperative course was uneventful. This approach is able to interrupt the fistula safely without interfering with normal coronary flow. Closure of the outlet and division of the fistula itself is a recommendable method to insure interruption of fistulous communication.

Adult↗

A newly developed silicone-coated membrane oxygenator for long-term cardiopulmonary bypass and cardiac support.

The surface of polypropylene hollow fiber was successfully coated with a very thin (0.2 micron) silicone layer. Experimental studies were performed in long-term (6 h) normothermic cardiopulmonary bypass (CPB) using 10 goats. A conventional membrane oxygenator (Mera Excelung HPO-15H, MERA, Tokyo, Japan) was used for 5 goats as a control (Group C) and a new silicone-coated membrane oxygenator, which is of the same construction as that of the one used for Group C, for 5 (Group S). The O2 transfer and CO2 removal functions showed the same ranges. In the other parameters, there were no differences between the 2 groups. As for hemolysis, however, the plasma free hemoglobin of Group S was lower than that of Group C. Currently, 3 chronic percutaneous cardiopulmonary support (PCPS) experimental models have been conducted, and there has been no evidence of thromboembolism or deterioration of the oxygenator. In conclusion, this new oxygenator is suitable not only for CPB, but also for long-term cardiac support.

Animals↗

Renal circulation and cellular metabolism during left ventricular assisted circulation: comparison study of pulsatile and nonpulsatile assists.

We examined left ventricular assist during 6 h for an acute myocardial infarction model in pigs. The outflow cannula was placed in the ascending aorta and an inflow cannula in the left atrium. A pump (Pulsatile group: Zeon Medical and Nonpulsatile group: Nikkiso HPM-15) was connected to each cannula. Items measured were the regional blood flow of the cortex and the medulla in the kidney, renal arterial flow, arterial blood ketone body ratio (AKBR), lactate/pyruvic acid, BUN, creatinine and beta 2-microglobulin. After experimental study, the kidneys were removed, and a pathological study was performed. In the pulsatile assisted group, renal cortical blood flow increased but medulla blood flow decreased. On the other hand, in the nonpulsatile assisted group, both regional blood flows decreased. That means that in the pulsatile assisted group intrarenal redistribution improved, rather than in the nonpulsatile assisted group. The results of our study indicated that pulsatile assist produced superior circulation in the kidney, and the microcirculation on the cell level was superior as well in early treatment of acute left heart failure.

Animals↗

[A case of primary fibrous histiocytoma of the lung].

Fibrous histiocytoma is non-epithelial malignant tumor mainly arising from soft tissue in extremities and body. Those derived from lung are rare. A 71-year-old female was admitted to our hospital because of an abnormal shadow on chest X-ray film. Preoperative diagnosis was not obtained by various examination. The tumor was located in right upper lobe (S2) and partial resection of right upper lobe was performed. Pathological diagnosis was fibrous histiocytoma of borderline malignancy. After the operation, adjuvant therapy was not done. The patient is doing well without recurrence and metastasis, during 4 years after the operation. However, careful follow-up should be necessary for long term.

Aged↗

[Three-dimensional transesophageal echocardiographic assessment for prosthetic valves].

We evaluated three-dimensional transesophageal echocardiographic assessment of the implanted mechanical valves by rotational scanning method. Patients were 7 mitral valve replacement and one aortic valve replacement, 2 mitral and aortic valve replacement. In 2 cases of 7 mitral valve replacement, the prosthetic valve regurgitation was evaluated using by color Doppler echocardiography. In this study, multiplane transesophageal probe was used. It rotated at 2-degree intervals from 0 to 180 degrees and the three-dimensional reconstruction was performed by echo scan workstation system (TOMTEC Inc, Munich, Germany). In mitral valve replacement cases, the valve motion of bileaflet valve (St. Jude Medical valve and ATS valve) were showed very clearly. The struts was easily recognized in the St. Jude Medical valve (SJM valve) cases. In one of SJM valve cases, the pannus formation was revealed, but it did not disturb valve motion. The prosthetic valve regurgitation can be seen accurately. However, aortic valve and ball valve cases cannot be reconstructed because of artifact from prosthetic valve and ultrasonic direction. The prosthetic valve regurgitation, pannus formation which was difficult to be showed in two-dimensional echocardiography and relationship between annulus and sewing cuff can be evaluated by this three-dimensional echocardiography. In this study, this system has some problems, for example real-time evaluation is impossible, aortic valve and ball valve cases cannot be reconstructed. However, we think that this new technology is suitable for evaluating valve thrombus, valve dysfunction and paravalvular leakage. In conclusion, the three-dimensional echo-cardiography demonstrated, reliable and accurate examination, and it can evaluate various complications of prosthetic valve.

Adult↗

Comparison studies of major organ microcirculations under pulsatile- and nonpulsatile-assisted circulations.

In these comparison studies, we examined changes in major organ microcirculations during circulatory support using pulsatile and nonpulsatile pumps. Acute myocardial infarction was created by left anterior descending (LAD) branch ligation. After the animals in these studies fell into cardiogenic shock, they were supported by mechanical assist devices: a pulsatile ventricular assist device (VAD) in 4 pigs, a nonpulsatile VAD in 4 pigs, and an intraaortic balloon pumping (IABP) plus nonpulsatile VAD in 4 pigs. Each group was supported for 3 h with an identical mean aortic pressure being maintained. As for parameters, the stomach mucosa, liver regional blood flow, stomach mucosal pH, and arterial blood keton body ratio (AKBR) were measured. Both regional blood flow and AKBR increased in the pulsatile group as compared with the nonpulsatile group. There were no differences in the stomach mucosal pH among the 3 groups. These results suggest that pulsatile assist rather than the nonpulsatile assist plays a significant role in the recovery of deteriorated splanchnic organs due to cardiogenic shock.

Animals↗

Coronary microcirculation during left heart bypass with a centrifugal pump.

To estimate coronary microcirculation during left heart bypass (LHB), we performed an experimental comparison study of LHB and intraaortic balloon pumping (IABP). LHB was performed with a BioMedicus BP-80 pump supporting half of the flow of cardiac output whereas the IABP was pumped in a 1:1 mode for cardiogenic shock in a swine model. Coronary circulations were analyzed by electromagnetic flowmeter, pulsed Doppler velocimeter, and laser Doppler flowmeter. Left ventricular end-diastolic pressure (LVEDP) was reduced significantly by LHB. Although there was no significant difference in epicardial flow between the LHB and IABP groups, endo cardial flow was increased significantly by LHB. In the LHB group, the systolic reverse wave of the coronary velocity called a myocardial invalid circulation was reduced remarkably. There was a significant inverse correlation between endocardial flow and LVEDP. These results suggested that LHB was more effective for myocardial microcirculation than was IABP.

Animals↗

Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock.

To estimate microcirculation of the heart and kidney in pulsatile and nonpulsatile-assisted circulation, a comparison study was done using a swine model. Acute myocardial infarction was made by ligation of the left coronary artery branches. After cardiogenic shock, animals were divided into 3 groups as follows: Group C (n = 6), no assist provided; Group NP (n = 6), assisted by a nonpulsatile pump (Bio-Medicus BP-80); Group P (n = 6), supported by a pulsatile pump (Nippon Zeon). left coronary artery flow, endocardial and epicardial regional flows, and renal cortex and medulla tissue blood flows were measured. Left coronary artery flow and endocardial and epicardial tissue blood flows decreased in cardiogenic shock, and they recovered to the control level soon after support in both Group N and Group P. Renal medulla and cortex tissue blood flows decreased in cardiogenic shock, and these flows did not recover in either Group N or P. However, cortex blood flow in Group P did improve, but it did not improve in Group N. These results suggested that pulsatile assist was more effective than nonpulsatile assist for microcirculation after cardiogenic shock to avoid deterioration of major organ functions.

Animals↗

[A case of primitive neuroectodermal tumor from rib].

Primitive Neuroectodermal Tumor (PNET) is a small round cell malignancy arising in bone and soft tissue. With the progress of immunohisto-chemical and ultrastructural studies, the tumor has getting attention. We report a rare case of PNET arising from rib. A 19-year-old man was admitted to our hospital complaining of chest and back pain. The tumor arised from 5th rib and en bloc resection was performed. Pathological diagnosis was PNET. After the operation, he is doing well, except being treated with chemotherapy (T9-protocol).

Adult↗

[A case of mitral stenosis with a new open pivot bileaflet valve].

The ATS Medical Open Pivot Bileaflet Valve was developed by Villafana who also developed St. Jude Medical valve and put to the first clinical use by Sadeghi on May 4, 1992. Since then, its clinical uses have been made in cases more than 1,000 in the world, centering on Europe, and its usefulness has been reported elsewhere from the aspected of its durability, anti-thrombogenic property, hemolysis, less noise and surgical operability. ATS valve was developed with 9 characteristics as (1) open pivot; (2) removed Struts; (3) wide area orifice; (4) improved stillness; (5) improved durability; (6) small loss of energy; (7) rotating orifice; (8) x-ray impermeability of orifice; (9) and easily sutured orifice. A report is made here on our experience of a clinical case of mitral stenosis by ATS valve (the first case in Japan) on September 28, 1993.

Female↗

The role of pulsatility in end-organ microcirculation after cardiogenic shock.

To estimate the effectiveness of pulsatility in end-organ microcirculation after cardiogenic shock, experimental studies using swine were done. Cardiogenic shock was produced in 14 pigs by ligating the left anterior descending branches so that mean aortic pressure dropped to 60% of the control value. After inducing shock, left atrial to ascending Ao bypass was initiated. A pneumatic pulsatile pump (Zeon Medical Inc, Tokyo, Japan) was used in seven pigs (Group P) and a centrifugal pump (BP-80, BioMedicus Inc, Minneapolis, MN) in seven (Group NP). In both groups, about half the usual cardiac output was supported for 3 hr, maintaining mean aortic pressure at approximately 100 mm Hg. The pulse pressure was 36.6 +/- 4.6 mm Hg in Group P, and 14.3 +/- 1.5 mm Hg in Group NP. Epicardial and endocardial regional flows recovered after assist in both groups. There were no significant differences between the two groups. However, liver tissue flow, renal cortex flow, and stomach mucous flow in Group P was significantly higher than those of Group NP after support (p < 0.05). In addition, arterial blood ketone ratio in Group P was 0.61 +/- 0.13 vs 0.39 +/- 0.06 in Group NP, a significant difference (p < 0.05). These results suggest that in uneven blood flow distribution of end organs after cardiogenic shock, pulsatility was effective in improving and maintaining function and microcirculation of end organs, preventing multiorgan failure.

Animals↗

Clinical evaluation of the Gyro Pump C1E3 as a cardiopulmonary bypass pump.

The Gyro Pump C1E3 is a new centrifugal pump with numerous features, including a ceramic pivot bearing system, secondary vanes, and an eccentric inlet port. To evaluate its biocompatibility, antithrombogenicity, and produced hemolysis, we used the Gyro Pump during cardiopulmonary bypass (CPB) for coronary artery bypass grafting (CABG) cases to compare it with the BioMedicus pump. From September 1998 to February 1999, 30 consecutive patients underwent CABG under conventional CPB. Fifteen patients were supported by the Gyro Pump C1E3 (Group G), and the remaining 15 patients, by a BioMedicus BP-80 pump (Group B). In both groups, flow rate was equivalent. Blood samples were taken as follows: preoperative, 60 minutes after the end of the procedure, and at postoperative days (POD) 0, 1, and 2. We evaluated the plasma free hemoglobin (free Hb) as an indication of hemolysis; beta-thromboglobulin (beta-TG) and platelet factor four (PF-4) as an indication of platelet deterioration; C3, C4, CH50 for complement activation; coagulation parameters, fibrinolytic factor, thrombomodulin, nitric oxide (NO), and endothelin as an indication of endothelial deterioration. This was the first clinical sized Gyro Pump CIE3. De-airing from the pump was easily accomplished via the eccentric oblique inlet port. The system, including its console, was easily and simply controlled. Perioperative laboratory data were not markedly changed in either group with demonstrated equivalence for biocompatibility and hemolysis. After pumping, no thrombus formation or pivot wear were observed inside the pump. This atraumatic, small centrifugal pump appears well suited not only for CPB but also for circulatory support.

Aged↗