Radial keyhole sequences for low field projection reconstruction interventional MRI.

Interventional magnetic resonance imaging (IMRI) is a rapidly emerging application for MRI in which diagnostic and therapeutic procedures are performed with MR image guidance. Real-time or near-real-time image acquisition and relative insensitivity to motion are essential for most intraoperative, therapeutic, and diagnostic procedures performed under MR guidance. The purpose of this work was to demonstrate the development and utility of two alternative rapid acquisition strategies during IMRI that are analogous to computed tomography fluoroscopy or keyhole MRI in a radial rather than rectilinear coordinate frame. The two strategies discussed here, interleaved projection reconstruction and continuous projection reconstruction, are compared and the feasibility of their application in experimental interventional applications is studied. J. Magn. Reson. Imaging 2001;13:142-151.

Animals↗

Two-step navigatorless correction algorithm for radial k-space MRI acquisitions.

A new way to correct magnetic resonance image artifacts resulting from view-dependent phase variations and view-dependent variations in rigid body object translation is presented by exploiting basic properties of the trajectory of radial k-space acquisitions. Simulations, phantom studies, and in vivo experiments are used to demonstrate the feasibility and the utility of this method. While somewhat analogous to navigator echo correction, in which special gradients are interleaved into the imaging sequence so echoes at the center of k-space can be acquired prior to or after collection of the image data, the current method does not require additional new gradient structures within the pulse sequence or increases in scan time. The new method uses the phase information from all collected radial k-space data points rather than only the navigator echo, which permits correction of multiple sources of view-dependent phase variation in the image data. The resultant effect is improved image quality in radial MRI acquisitions. Magn Reson Med 45:277-288, 2001.

Algorithms↗

A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence.

This work demonstrates the feasibility of using wireless, tuned fiducial markers with a limited projection reconstruction-fast imaging with steady-state free precession sequence (LPR-FISP) to accurately obtain tracking information necessary for interactive scan plane selection in magnetic resonance imaging (MRI). The position and orientation of a rigid interventional device can be uniquely determined from the 3D coordinates of three fiducial markers mounted in a known configuration on the device. Three fiducial markers were tuned to the proton resonant frequency in a 0.2T open MR scanner and mounted to the surface of a cylindrical water phantom. An LPR-FISP sequence was developed to suppress the water phantom signal while preserving that of the fiducial markers through a nonselective low-tip-angle excitation and a dephaser gradient applied prior to data acquisition. A localization algorithm was developed to accurately calculate the 3D coordinates of the fiducial markers using four LPR-FISP projections in two orthogonal scan planes. The sequence repetition time (TR = 21 msec) and the limited projection set resulted in fast LPR-FISP coordinate acquisition times of approximately 170 msec with an accuracy (max error) of 3 mm on a 0.2T MR system. This fast, accurate tracking method provides the fundamental technology for interactive MRI scan plane definition for rigid interventional devices without the need for stereotactic cameras or reference frames.

Algorithms↗

[Comparison of susceptibility artefacts of different radiofrequency electrodes at O.2 T. Influence of electrode positioning, pulse sequence and image reconstruction methods].

PURPOSE: Interventional MRI procedure monitoring requires small but accurate susceptibility artifacts of the instruments used. In this investigation, susceptibility artifacts of different RF-electrode designs were compared using a variety of pulse sequences and k-space acquisition methods. METHODS: 4 different 18-gauge RF-electrodes (with three single electrodes made of stainless steel, copper, inconal, and a triple-clustered electrode configuration made of inconal) were placed in a 0.2 T MR-scanner perpendicular to the main magnetic field. Pulse sequences used included: TSE T2, FISP, true-FISP, PSIF, and a temperature sensitive ES-GRE sequence. In addition to the 2D Cartesian k-space trajectory with Fourier transformation (2DFT), projection reconstruction (PR) was used with the FISP, true-FISP and PSIF sequences. RESULTS: The best tip accuracy was achieved with the combination of inconal electrodes and TSE T2. The usefulness of the tested sequences was found to be: TSE T2 > PSIF > FISP/true-FISP > ES-GRE. In general 2DFT provided better or equal tip accuracy than PR. The apparent shaft width was smaller using the copper electrode compared to the inconal electrode. However, the "match shaped" tip artifact of the copper probe led to a higher error in tip accuracy. CONCLUSIONS: TSE-T2 sequences and Cartesian 2DFT acquisitions should be used for accurate tip positioning at 0.2 T. Further, artifact size of the electrode shaft prevents the use of inconal for temperature sensitive sequences. Copper electrodes can be used for these purposes, although copper is not considered to be biocompatible at present.

Artifacts↗

Segmented k-space and real-time cardiac cine MR imaging with radial trajectories.

The authors developed and evaluated two cine magnetic resonance (MR) imaging sequences with a radial rather than a rectilinear k-space coordinate frame: segmented k space and real-time true fast imaging with steady-state precession, or FISP. The two radial k-space segmentation (or view sharing) techniques, which were interleaved or continuous, were compared, and the feasibility of their application in cardiac cine MR imaging was explored in phantom and volunteer studies. Images obtained with the radial sequences were compared with those obtained with two-dimensional Fourier transform, or 2DFT, sequences currently used in cine MR imaging. Temporal resolution of 55 msec was achieved with the real-time radial sequences, which allowed acquisition of almost 19 high-quality images per second.

Adult↗

Temperature measurement using echo-shifted FLASH at low field for interventional MRI.

We investigated the feasibility of using echo-shifted fast low-angle shot (FLASH) for temperature-monitored thermo-therapeutic procedures in a 0.2 T interventional magnetic resonance (MR) scanner. Based on the proton resonance frequency shift technique, modified echo-shifted FLASH has sufficiently high signal-to-noise ratio to provide accurate temperature maps with short scan times, i.e., 5 seconds in phantoms (TR = 20.5 msec; effective TE = 30 msec; one echo shift; NSA = 2) and ex vivo experiments (TR = 19.4 msec; effective TE = 28.9 msec; one echo shift; NSA = 2) and 3 seconds (TR = 19.4 msec; effective TE = 28.9 msec, one echo shift; NSA 1) for an in vivo case. The proton resonance frequency shifts with temperature observed in a 0.2 T MR scanner using this sequence were -0.0072 ppm/degrees C (temperature uncertainty = +/-2.5 degrees C) for polyacrylamide phantoins and -0.0086 ppm/degrees C (temperature uncertainty = +/- 1 degrees C) for ex vivo bovine liver. These experiments demonstrated that echo-shifted FLASH is a viable method for low-field temperature monitoring despite the decreased signal and decreased phase sensitivity compared with its counterpart in a 1.5 T MR imaging system. The improved temporal resolution of temperature images, now possible in low-field interventional MR systems using echo-shifted FLASH, will allow clinicians more accurate monitoring of interstitial ablation in MR-guided interventional procedures.

Animals↗

Temperature Measurement Using Echo-Shifted FLASH at Low Field for Interventional MRI.

Temperature Measurement Using Echo-Shifted FLASH at Low Field for Interventional MRI. Yiu-Cho Chung, Jeffrey L. Duerk, Ajit Shankaranarayanan, Monika Hampke, Elmar M. Merkle, and Jonathan S. Lewin. (Article was originally published in the Journal of Magnetic Resonance Imaging, Volume 9, No. 1, 1999). In this article, some of the references were printed with the incorrect journal name. Here is the corrected list of references for this article.

Journal Article↗

Effects of superparamagnetic iron oxide on radio-frequency-induced temperature distribution: in vitro measurements in polyacrylamide phantoms and in vivo results in a rabbit liver model.

PURPOSE: To determine whether contrast medium containing superparamagnetic iron oxide (SPIO) alters radio-frequency (RF)-related temperature distribution in acrylamide phantoms and in an in vivo model. MATERIALS AND METHODS: In nine acrylamide phantoms with increasing SPIO content, RF was applied with simultaneous measurement of temperature profile along the probe track. Additionally, magnetic resonance imaging-guided RF ablation was performed in the liver of six rabbits after the intravenous administration of SPIO (0.05 mL per kilogram of body weight) 40 minutes prior to ablation (SPIO group) and in another six rabbits without prior SPIO administration (control group). Coagulation diameter was evaluated on the basis of postprocedural imaging and subsequent gross pathologic findings. Statistical analysis was performed with the Student t test. RESULTS: In the phantoms, progressive increases in iron content resulted in higher temperatures along the RF electrode track (P < .05). In the in vivo model, however, SPIO at physiologic concentrations did not significantly increase the diameter of coagulation on the basis of either postprocedural imaging or subsequent gross pathologic findings. Additionally, no significant differences were seen in other RF-related parameters including impedance, voltage, current, and grounding pad temperature. CONCLUSION: Administration of SPIO in conjunction with RF ablation of focal liver lesions is feasible and safe, but no significant difference in the extent of induced coagulation can be expected.

Acrylic Resins↗

Developing a multichannel temperature probe for interventional MRI.

Interventional MRI (I-MRI) guided thermal tissue ablation has been used for a variety of interventional cancer therapies. These would be further facilitated by temperature-sensitive sequences on low magnetic field MR images. However, until these sequences have been reliably implemented at low fields, other methods of temperature measurement are required. This project describes the development of a low cost, reliable, MRI-compatible temperature sensor array useful at a temperature range from 37 degrees C to higher than 90 degrees C. The device uses a three-channel thermocouple sensor array connected to a variety of filtering and signal-conditioning electronics, analog-to-digital (A/D) converters, and personal computers. The sensors induce negligible field distortion. Similarly, no MRI-based measurement artifacts are observed. One-dimensional temperature profiles are generated with thermocouple signal linearization performed by the software.

Equipment Design↗